Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 25, 2015 FBO #4992
MODIFICATION

43 -- LD Thrust Bearing Pump and Motor Sets

Notice Date
7/23/2015
 
Notice Type
Modification/Amendment
 
NAICS
333996 — Fluid Power Pump and Motor Manufacturing
 
Contracting Office
USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362-1876
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF-15-R-SS59
 
Response Due
7/27/2015
 
Archive Date
9/21/2015
 
Point of Contact
Cynthia Jacobsen, 509-527-7203
 
E-Mail Address
USACE District, Walla Walla
(cynthia.h.jacobsen@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Subject Sources Sought for the Supply and Delivery of 6 NEW Thrust Bearing Pump and Motor sets for Ice Harbor Lock and Dam located at 2763 Monument Dr., Burbank, WA 99323. Contractor shall supply and deliver 6 NEW Thrust and Bearing Pump and Motor Sets as described below SCOPE Contractor shall furnish and deliver new thrust bearing pump and motor sets to Ice Harbor Lock & Dam. Refurbished pumps shall be cause for rejection. Upon request, two sets of technical documentation, including pump performance curves, NPSHR, component specifications, motor data, mounting dimensions and sales drawings shall be submitted to the technical point of contact at site (through Contracting Office), for technical evaluation, prior to contract award. Three sets of O & M manuals shall be included with the delivery. less than /p greater than Mechanical The pump and motor sets shall meet the following specifications. Pump and motor shall be sized to deliver turbine oil at specified flow rate and suction condition without cavitation. Pump suction will be located 6' below static fluid level (below sump). Suction piping will consist of up to 15' of 1-1/4 quote mark OD stainless steel tubing, with a suction strainer. Additional operating conditions for the turbine oil are given below: less than /p greater than Pump Type: Heavy Duty Gear Pump Fluid: Turbine Oil (VG ISO 100) Fluid Operating Temperature: 50 F - 110 F Minimum Flow Rate: 9.7 GPM Max Rated Discharge Pressure: 2000 psi Suction Condition: Flooded less than br / greater than Min. Suction Connection: 1-1/2 quote mark Min. Discharge Connection: 1-1/2 quote mark Connection Type: SAE J518 Code 61 4-bolt flange Gear Type: External Gear Material: 8620 alloy steel, hardened and surface ground Shaft Material: 8620 alloy steel, hardened and surface ground Shaft Seal: Flowserve Type 21 Mechanical Seal - Carbon face/Niresist mating ring/Viton Elastomer or quote mark Approved Equal quote mark - (Fluoroelastomer Service Temperature 200 C) O-Rings: Viton or quote mark Approved Equal quote mark - (Fluoroelastomer Service Temperature 200 C) Pump Bearings: AISI 52100 Roller bearings, heat treated, minimum L10 Life of 10000 Hrs @ 2000 psi Pump/Motor Coupling: C-Face Adapter Motor Voltage: 460 VAC Motor Frequency: 60 Hz Max Motor Current: 30 A Motor Connection Box Location: Top Duty Class: Continuous Frame: TEFC or TENV Mini Service Factor: 1.15 Mounting Plate: ASTM A36 Carbon Steel Each pump and motor set shall be supplied close coupled, dynamically balanced, and mounted to a solid base. The base shall be sufficiently rigid to support the motor and pump, and maintain flatness to avoid frame deflection, without the use of additional supports or members. Due to extreme environmental sensitivity, leaking seals, at any rate, shall not be acceptable. SCHEDULE Delivery by September 24, 2015. Contractor shall make prior arrangements with the Government personnel at site to deliver and unload the equipment. THIS IS NOT A SOLICITATION This information is for planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Interested parties that respond to this sources sought announcement should submit the following information: 1) Your intent to submit a quote for this project when it is formally advertised 2) Name of firm with address, phone and point of contact. 3) CAGE Code and DUNS number or a copy of your System for Award Management (SAM) information 4) The category of small business, such as 8(a), HUBZONE, or SDVOSB etc. Interested parties should submit their responses to Cyndi Jacobsen, Contract Specialist, via email to cynthia.h.jacobsen@usace.army.mil. Your response to this notice must be received by 10:00 AM PST, July 28, 2015.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-15-R-SS59/listing.html)
 
Place of Performance
Address: Ice Harbor Lock and Dam less than br greater than 2763 Monument Dr. less than br greater than Burbank, WA
Zip Code: 99323
 
Record
SN03807646-W 20150725/150723235038-5c6db819b73b0ecf5d86b98f8a63a89f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.