Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 15, 2015 FBO #5013
SOURCES SOUGHT

66 -- NAI Sensor

Notice Date
8/13/2015
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of Energy, National Security Technologies LLC (DOE Contractor), National Security Technologies LLC, PO Box 98521, Las Vegas, Nevada, 89193
 
ZIP Code
89193
 
Solicitation Number
081315-SH-15
 
Archive Date
9/3/2015
 
Point of Contact
Sheppy, Phone: 702-295-3060, Emma B Fox, Phone: 702.295.0507
 
E-Mail Address
herskosd@nv.doe.gov, foxeb@nv.doe.gov
(herskosd@nv.doe.gov, foxeb@nv.doe.gov)
 
Small Business Set-Aside
N/A
 
Description
Interested parties are requested to provide their company information to include POC with phone number, email address and business size to Sheppy herskovic no later August 19, 2015, 5:00 p.m., Pacific Standard Time. Determination of Small Business set-aside will be made based on responses received.Please provide a capabilities statement with supporting literature such as cut sheets, descriptive literature, catalogs etc. which will demonstrate how your product will meet the following requirements and also list if you are the manufacturer or reseller: NAI Sensor Specification Revision D Date: 2-11-13 1. Material NaI(T1) 1" x 3.24" Select Premium Grade crystal, or equal. 2. Aluminum housing that is integral environmentally sealed that can with stand 8' of water emersion or 3.5 psi. 3. Photomultiplier is a Hamamatsu ( no substitute) R1924-01 with flying leads with a mu-metal wrap. Cathode Blue sensitivity index of 11.0 or better. Mu-metal shielding sufficient to limit the gain shift at 662 KeV of a deviation less than 1% when the axis of the detector is rotated 360 degree in the x.y plane and the x,z plane. Relative to the x.y plane that is parallel to plane of the surface of the earth. 4. Pulse Height Resolution 7.5% or better at 662KeV ( Cs-137 ). 5. Wires should be attached to a 14 pin base Wire supplied by STL to be soldered to flying leads of PMT. 24 AWG rated at 600V and 1000V which are specified in list. The following color will be attached to each flying lead of the PMT. K= black, DY1= brown, DY2= red, DY3=orange, DY4= yellow, DY5= green, DY6= blue, DY7= violet, DY8=Gray ( 600V),DY9= white ( 600V), DY10= Gray ( 1000V), Anode= white ( 1000V). Wire length will be 15" from end of flying lead 6. Storage temperature -20 C to 55 C. 7. Operating temp -20C to 50 C. 8. Sensor assembly is preloaded to withstand 25G force. 9. Dark current measurement will be under 20nA with lead shielding and background and system cabling subtracted. This measurement will be made at 700V and will be measured within approximately 5 minutes, with a +15 minute window. 10. Gain Stability measurement will be made at 30 minutes and 60 minutes with +15 minute test window. The two measurements will be compared within a 2% of change to be acceptable. 11. No stickers or manufactures stickers are to be on the sensor. Only engraved serial and part numbers. Interested parties are requested to provide their company information to include POC with phone number, email address and business size to Sheppy Herskovic no later than August 19, 2015 by 5:00 p.m., Pacific Standard Time. Determination of Small Business set-aside will be made based on responses received.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/BNC/BV/081315-SH-15/listing.html)
 
Place of Performance
Address: Goleta, CA, Goleta, California, United States
 
Record
SN03837490-W 20150815/150813235538-ad9dec84255cee27e4b2f0036eca5e96 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.