Description
The contractor shall perform a general inspection of the compressor at each service visit to ensure proper operation and to identify existing or potential problems. The results of the air certification tests shall be sent to RRAD as soon as they become available. Deficiencies in the air certification test results shall be highlighted to permit correction. The services listed below shall be performed at least the number of times indicated during the contract period. The contractor shall determine the most appropriate time to perform the services based on his inspections. Change compressor and purifier cartridges twice. Change compressor oil once. Change intake filter once. Change mechanical filter once. Test air each visit. SCBA. The services required on the SCBA can be divided into quarterly inspections and functional tests. Inspections, adjustments, and repair shall be performed by a factory trained technician. Certifications needed: Scott Technician SCBA Certification. TRI Certification Quarterly Inspections. The contractor shall inspect all depot SCBA in accordance with manufacturer guidelines quarterly beginning within 10 days of contract award. Each service visit shall be documented and a copy of the report provided to the Contracting Officer. The functional test shall be performed in lieu of the quarterly inspection in accordance with the next paragraph. Functional Tests. The contractor shall perform a functional test of all depot SCBA on the service visit closest to October of the contract period. The contractor shall notify the Contracting Officer at least one week prior to the tests to facilitate the collection of the SCBA. The functional test results shall be documented and a copy of the report provided to the Contracting Officer. Parts. The cost for all the parts and materials required to perform the services on the compressor including filter elements, cartridges, oil, o-rings, and test kits shall be included in the cost of this service contract. Replacement parts used or recommended for use shall be designed specifically for the specific compressor or SCBA being repaired. Possible Compressor Parts Needed: YVA-3010-A Sherwood Valve 72-3942 Dump Piston 09-2-2165 Dump Piston O-ring 96201-BB4-T4 Pressure Switch 36713-00 Valve Seat 36714-00 Copper Gasket 37091-01 Packing Washer 37079-01 Preformed Packing Possible SCBA Parts Needed: 804481-01 Belt, Waist to Shoulder ASSY 200188-04 HSG ASSY, HUD Driver Module 802229-02 Hose Assembly 200083-01 Diaphragm & Valve ASSY, EZ FLO+ 200674-02 Gauge ASSY, Air-Pak, 4500 PSIG
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/90f7ea85dfa720b52af5898db2908d99)
 
Place of Performance
Address: ACC- Warren (ACC-WRN)(RRAD) ATTN: CCTA-HDR, 100 Main Drive, Building 431 Texarkana TX
Zip Code: 75507-5000
 
Record
SN03870508-W 20150905/150903235924-90f7ea85dfa720b52af5898db2908d99 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.