SPECIAL NOTICE
66 -- Full Service Maintenance Renewal Agreement for MACSQuant Analyzer 3036 - Justfication for Miltenyi
- Notice Date
- 12/22/2015
- Notice Type
- Special Notice
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, National Institutes of Health, Office of Administration, 6011 Executive Blvd, 5th Floor, Rockville, Maryland, 20852-3804, United States
- ZIP Code
- 20852-3804
- Solicitation Number
- NIH-OLAO-OA-NOI-4028475
- Archive Date
- 1/15/2016
- Point of Contact
- Van V. Holley, Phone: 301-594-9439
- E-Mail Address
-
holleyv@od.nih.gov
(holleyv@od.nih.gov)
- Small Business Set-Aside
- N/A
- Description
- The MACSQuant is manufactured by Miltenyi Biotec The National Institutes of Health, Office of Logistics and Acquisition Operations, on behalf of the National Eye Institute intends to issue a fixed price award to a single source under the authority of FAR 13.106-1(b)(1), soliciting from a single source. An award will be made on or about 31 December 2015 to Miltenyi Biotec for one base year and two renewal option years on government-owned MACSQuant VYB Unit #3036. All maintenance services shall be performed in accordance with the manufacturers standard commercial maintenance practices. The contractor shall perform planned maintenance service, repair service ( incl material cost for laser heads) and Technical Support Services. PREVENTIVE MAINTENANCE: Contractor shall perform Regular Maintenance Two 2 scheduled maintenance visits Performance assurance checks Functionality and safety checks Safety inspections in accordance with all applicable regulations Cleaning of operational and inorganic contaminations Cleaning and greasing of mechanical parts Components check up Routine inspection and replacement of the following wearing parts: 2 x Pump Syringe 1 x 4-port Distribution Valve 2 x 4-port 4-way Valve 2 x Dilutor Valve, 6-port distribution 3 x Peristaltic Pump Heal incl. tube 1 x Silicone Sleeve, washing station 1 x Sterile Filter Pall Ultipor N66 1 x Rear Fan Air Filter 6 x Hydrophobic Air Filter 3 x Silicon Tubes Repair Service Repair of instrument defects Detailed service documentation EMERGENCY SERVICE Interactive telephone and electronic mail support for the purpose of resolving technical support incidents REPLACEMENT PARTS: Arrangement of the parts and labor for all necessary repairs Technical Support Services/General SOFTWARE UPDATES/SERVICE Device software update included PERIOD OF PERFORMANCE: Period of Performance shall be for twelve (12) months from January 1, 2016 to December 31, 2016 and two additional optional years, OY1- January 1, 2017 to December 31, 2017, OY2- January 1, 2018 to December 31, 2018. PLACE OF PERFORMANCE Service shall be performed at the following location: 9000 Rockville Pike Building 10, Room 10N112 Bethesda, Maryland 20892 The North American Industry Classification System (NAICS) code for this requirement is 334516 with the size standard of 500 employees. This notice of intent is not a request for proposals or quotes; however, all responsible sources may submit a quotation and technical capabilities, which, if received within ten calendars days of publication of this notice, shall be considered by NIH/NEI. All responses must be submitted to the Government point of contact at holleyv@od.nih.gov. A determination by the Government not to open the requirement to competition based upon the responses to this notice is solely within the discretion of the Government.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/OoA/NIH-OLAO-OA-NOI-4028475/listing.html)
- Place of Performance
- Address: NIH MAIN CAMPUS, 9000 ROCKILLE PIKE, BUILDING 10, ROOM 10N112, Bethesda, Maryland, 20892, United States
- Zip Code: 20892
- Zip Code: 20892
- Record
- SN03976510-W 20151224/151222234815-aa3825d48e5f9dbb9390fd7e840a1863 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |