Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 14, 2016 FBO #5165
SOURCES SOUGHT

66 -- Servo-Hydraulic Tensil Test System

Notice Date
1/12/2016
 
Notice Type
Sources Sought
 
NAICS
541712 — Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Weapons Division Dept. 1, Commander, NAWCWD, Code 210000D, 429 E. Bowen Rd - Stop 4015, China Lake, California, 93555-6108, United States
 
ZIP Code
93555-6108
 
Solicitation Number
N6893616R0017
 
Archive Date
1/18/2017
 
Point of Contact
Joel Blaine Ashworth, Phone: (760) 939-2459, Bryan V Gregory, Phone: (760) 939-1891
 
E-Mail Address
joel.ashworth@navy.mil, bryan.v.gregory@navy.mil
(joel.ashworth@navy.mil, bryan.v.gregory@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
This sources sought is intended to determine whether small business is capable or interested in filling this requirement. The Materials Engineering Division at Naval Air Warfare Center, Weapons Division at China Lake, CA requires the purchase of a Servo-hydraulic tensile test system and anticipates the delivery of the product within 45 days after award. Comments are welcome. Specific instructions and requirements are listed below: SPECIFICATION FOR SERVO-HYDRAULIC UNIVERSAL TEST MACHINE Materials Engineering Division, Code 434000D NAVAIR China Lake, CA Specification is for a servo-hydraulic universal test machine which can be used for tension, compression and cyclic/fatigue testing. 1) System shall have a minimum load capacity of 20,000 lbf in tension and compression directions. 2) System shall include a load cell capable of measuring minimum of 20,000 lbf. Load cell shall be capable of measuring tension, compression and cyclic/fatigue loads. Load accuracy shall be ±0.5% or better. 3) Actuator shall be located in the base of the load frame. 4) Actuator shall have a maximum rate of at least 6 inches per second. 5) Actuator shall have a stroke of 6 inches minimum. 6) Actuator shall be capable of cyclic/fatigue tests of 30 Hz or more for rigid samples at ±50% load capacity. 7) System shall have a moveable crosshead. With crosshead at highest position, there shall be 45 inch minimum opening between actuator and load cell (no grips or fixtures installed, actuator at mid-stroke). Crosshead shall be adjustable using hydraulic, pneumatic or electrical means. 8) Crosshead support columns shall have 20 inch minimum distance inside to inside. 9) System shall include a hydraulic pump capable of operating system. Maximum noise level of pump shall be 70 dB when measured at operator's console (note, due to space limitations, pump will be installed behind the load frame within 10 feet of operator). 10) Hydraulic pump may be water cooled using existing cooling system in Code 434000D lab. 11) All hoses, fittings, etc required to connect hydraulic pump to load frame and water cooling shall be included. System supplier shall provide appropriate quantity of hydraulic fluid. 12) System shall include upper and lower hydraulically operator wedge style grips, and shall include jaw faces for thin and thick flat samples, and small and large diameter round samples (minimum 4 complete sets of jaw faces). Jaw face sample size shall be manufacturer's standard sizing (e.g. 0.25 inch and 0.5 inch flat, 0.25 inch and 0.5 inch diameter round). 13) Hydraulic grips may be operated from main hydraulic pump, or from a separate dedicated pump. Hoses, fittings, etc required to connect grips to pump shall be included. 14) System shall include manual control console capable of controlling basic system functions. Multiple manual controllers may be used (e.g. 1 controller for crosshead/actuator position, 1 controller for grip opening/closing). 15) System shall include computer console for creating and running complex tests and for data capture. Supplier shall specify software package name and version number. Multiple software packages may be included for static and fatigue testing. Computer shall be Windows 7 or Windows 10 operating system, and shall include mouse, keyboard and monitor (20 inch minimum). All cables, interface cards, etc shall be included. 16) System shall include minimum of 4 external data outputs for load, position and 2 additional programmable channels (e.g. strain). Preferred output is ±10 volt BNC style, with user programmable output (e.g. 10 volts = 20,000 lbf, 10 volts = 2 inch, etc). Data acquisition shall be adjustable from 1 Hz or less to 5 kHz or higher for all channels. 17) System shall be capable of operating on any or all of the following electrical power (existing power in building) a. 480 volt, 3 phase, 60 amp b. 208 volt, single phase c. 110 volt, single phase Supplier shall indicate power requirements for all components (hydraulic pumps, load frame, computers, and any ancillary equipment). Any solicitation or Request for Proposal (RFP), as a result of this sources sought, will be posted on the FEDBIZOPPS website at http://www.fbo.gov. All responsible sources must be registered in the System for Award Management (SAM) database at the following website: https://www.sam.gov/portal/public/SAM/. Written responses shall be submitted by e-mail to joel.ashworth@navy.mil or mailed to Commander, Code 254140D, Attn: Blaine Ashworth NAVAIRWARCENWPNSDIV, 429 E. Bowen Rd. Mail Stop 4015, China Lake, CA 93555-6108 by 18 January 2016. Any firm believing it can fulfill the requirement identified above may submit a written response which shall be considered by the agency. The written response shall reference solicitation number N68936-16-R-0017 and provide a capability statement that clearly indicates the firm's experience, assets, background, and ability to perform the required work without compromising the quality, accuracy, reliability, and schedule.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVAIR/N68936D1/N6893616R0017/listing.html)
 
Record
SN03989267-W 20160114/160112234741-5428f14010f656de4324bf0d5caee304 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.