- Description
- Questions that arose from the subject solicitation and their respective answers follow: 1. How will the divider be used with JJVS? JVS will measure divided outputs. 2. How will the divider be used for calibrators and meters. Calibrators used as sources and Meters used to measure. a. Is here a specific measurement sequence? No b. Will the unit be kept turned on and if so, will the Reference Zener be continuously connected? Could vary with applications and requirements, some yes and some no, may be a function of Divider performance. 3. How will the AF verify the 90 day specification requirement? Using the JJVS