SOURCES SOUGHT
46 -- Saline Chlorinator System
- Notice Date
- 3/17/2016
- Notice Type
- Sources Sought
- NAICS
- 333318
— Other Commercial and Service Industry Machinery Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Space Command, 45CONS (Bldg 423), 1201 Edward H White II St MS 7200, Patrick AFB, Florida, 32925-3238, United States
- ZIP Code
- 32925-3238
- Solicitation Number
- FA2521-16-Q-B011
- Archive Date
- 4/9/2016
- Point of Contact
- Sandra Seman, Phone: 3214947092, James J. Honeycutt, Phone: 3214949950
- E-Mail Address
-
sandra.seman@us.af.mil, james.honeycutt.11@us.af.mil
(sandra.seman@us.af.mil, james.honeycutt.11@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT: THIS IS NOT A NOTICE OF REQUEST FOR PROPOSAL BUT INFORMATION AND PLANNING PURPOSES ONLY! It does not constitute a solicitation and/or quote and is not to be construed as a commitment by the Government. The Request for Quotation (RFQ) number is FA2521-15-Q-B011 shall be used to reference any written responses to this source sought. Patrick Air Force Base anticipates a requirement that is being considered under a small business set-aside program. The North American Industry Classification Systems (NAICS) Code proposed 333318. The size standard for NAICS is 1,000 employees. GSA SIN/MAS 51V 105 002 The requirement is to provide two (2) commerical salt generators systems for facility 917 and 528 on Patrick AFB, Fl. Salient Characteristics: Building 917--Industrial Grade Saline Chlorinator for "Tides Pool" 225,000 gallons @650-750 gallons/minute or evaluate: (1 each) 40.0 lb/day Saline Chlorination System-Horizontal # CH CHLOR 40.0H Industrial-grade electronic components for long system life Pre-mounted on backboard for wall installation Self-cleaning, clear view, Hi-output Reactor Chamber Integrated sidestream flow switch, and isolation valves Includes integral CK5000 Salinity monitoring & control module ORP interface for optional Controller with auto-switchover Systems carry NSF Std 50, and UL 1081 Certifications 3-Year Limited Factory Warranty Max input is 32 Amps @ 208-240V, 225 lbs DOH stand-alone sizing is 54 lbs based on a flow rate of 750 gpm (1-each)Salt Saturated Feeder, 55 Gallon (ChlorKing) # CP SSFEEDER55 For use with Automatic Salinity Control Packages Includes float tank 30 gallon, auto water level control, and dissolving tank Capacity - 550 Llbs of Salt (1 -each) 85 GPD Fixed Rate Stenner Feeder,#5,120V,1/4 BC 85MFL5A1S (1-each) Probe Clean Package. # BX Probe Clean Probe Clean Package Programmable self -priming probe clean chemical pump, 5 gallon sealed storage tank, and applicable clay weights, tubing, and fittings. Connects to probe cell assembly. (1-each) BECSys5. Chemical Controller-Ethernet-VFD-CP-1. # CJ BECSYS5-XS1TP1OPXX Direct control of both saline and redundant chlorinator BECSys5 Chemical Controller-Ethernet-VFD-CP-1 Includes Rotary Flow Switch & Check Valve, Lighted Flow Cell Assembly with acrylic mounting plate Demand Based Proportional Feed and Failsafe Circuits Complete interactive circuitry with alert notification (4) 4-20 circuits for vac & press readings, autofill, TDS, etc. (Sensors additional) Interactive Ethernet communications card - standard100Base T Ethernet (standard), BECSys Probes with Short Cables, & Four 4-20mA outputs for interface with VFD, includes 4 loop power supplies for 4-20mA inputs. Includes Digital Flow Sensor and PVC Saddle (specify pipe size) Factory 5-year Factory Electronics Warranty (1-each) SIGNET 6" PVC Saddle w/ adaptor, N80 PV8S060. # HD 5911.060 (1-each) Paddlewheel Lo Flow Sensor (5-8"), Blue Cap 3-2536-P1. # HD 5930.505 (1-each) Vacuum Transducer with 50' Cable. # CK 8660034 For use with BECSys5,BW,7 Requires one loop power supply channel (1-each) Salinity Control ORP Sensor Upgrade. # CH Salinity Sensor-ADD Salinity Control ORP Sensor Upgrade Upgrade from Standard ORP Sensor, plat band (9660022) to ORP Sensor Solid Gold Band (9660038) for Saline Applications. (1-each) Pulsar III System, PS5000. # BM 71528 Pulsar III System, PS5000, 120 lb/d, includes booster pump, venturi, and 1/2" Solenoid Assembly (1-each) POCES Equipment POCES-EQUIP (1-each) Pulsar III Solenoid Assembly BN Solenoid PIII Pulsar III Solenoid Assembly Include wall mounted solenoid assembly with mounting board, in-line strainer, compression fittings, solenoid sidestream isolation valves, and assorted pvc fittings (1-each) Installation and Factory Start-up of treatment equipment. Includes parts and labor for installation. Electrical work, permits by base personnel. Includes final review, training manual, full system and maintenance training per operator Training Checklist, and on-site. Warranty Administration. One year warranty on all installation workmanship. (1-each) Treatment Package Start Up Manual CB Start-Up Manual Building 528-Industrial Grade Saline Chlorinator for "Base Pool" 210,000 gallons @350-375 gallons/minute or evaluate: (1 each) 20.0 lb/day Saline Chlorination System-Horizontal # CH CHLOR 20.0H Industrial-grade electronic components for long system life Pre-mounted on backboard for wall installation Self-cleaning, clear view, Hi-output Reactor Chamber Integrated sidestream flow switch, and isolation valves Includes integral CK5000 Salinity monitoring & control module ORP interface for optional Controller with auto-switchover Systems carry NSF Std 50, and UL 1081 Certifications 3-Year Limited Factory Warranty Max input is 32 Amps @ 208-240V, 225 lbs DOH stand-alone sizing is 27 lbs based on a flow rate of 375 gpm (1-each)Salt Saturated Feeder, 55 Gallon (ChlorKing) # CP SSFEEDER55 For use with Automatic Salinity Control Packages Includes float tank 30 gallon, auto water level control, and dissolving tank Capacity - 550 Llbs of Salt (1 -each) 85 GPD Fixed Rate Stenner Feeder,#5,120V,1/4 BC 85MFL5A1S (1-each) Probe Clean Package. # BX Probe Clean Probe Clean Package Programmable self -priming probe clean chemical pump, 5 gallon sealed storage tank, and applicable clay weights, tubing, and fittings. Connects to probe cell assembly. (1-each) BECSys5. Chemical Controller-Ethernet-VFD-CP-1. # CJ BECSYS5-XS1TP1OPXX Direct control of both saline and redundant chlorinator BECSys5 Chemical Controller-Ethernet-VFD-CP-1 Includes Rotary Flow Switch & Check Valve, Lighted Flow Cell Assembly with acrylic mounting plate Demand Based Proportional Feed and Failsafe Circuits Complete interactive circuitry with alert notification (4) 4-20 circuits for vac & press readings, autofill, TDS, etc. (Sensors additional) Interactive Ethernet communications card - standard100Base T Ethernet (standard), BECSys Probes with Short Cables, & Four 4-20mA outputs for interface with VFD, includes 4 loop power supplies for 4-20mA inputs. Includes Digital Flow Sensor and PVC Saddle (specify pipe size) Factory 5-year Factory Electronics Warranty (1-each) SIGNET 6" PVC Saddle w/ adaptor, N80 PV8S060. # HD 5911.060 (1-each) Paddlewheel Lo Flow Sensor (05-4"), Blue Cap 3-2536-P1. # HD 5930.503 (1-each) Vacuum Transducer with 50' Cable. # CK 8660034 For use with BECSys5,BW,7 Requires one loop power supply channel (1-each) Salinity Control ORP Sensor Upgrade. # CH Salinity Sensor-ADD Salinity Control ORP Sensor Upgrade Upgrade from Standard ORP Sensor, plat band (9660022) to ORP Sensor Solid Gold Band (9660038) for Saline Applications. (1-each) Pulsar III System, PS5000. # BM 71528 Pulsar III System, PS5000, 120 lb/d, includes booster pump, venturi, and 1/2" Solenoid Assembly (1-each) POCES Equipment POCES-EQUIP (1-each) Pulsar III Solenoid Assembly BN Solenoid PIII Pulsar III Solenoid Assembly Include wall mounted solenoid assembly with mounting board, in-line strainer, compression fittings, solenoid sidestream isolation valves, and assorted pvc fittings. (1-each) Installation and Factory Start-up of treatment equipment. Includes parts and labor for installation. Electrical work, permits by base personnel. Includes final review, training manual, full system and maintenance training per operator Training Checklist, and on-site. Warranty Administration. One year warranty on all installation workmanship. (1-each) Treatment Package Start Up Manual CB Start-Up Manual NOTE: RESPONSES TO THIS SOURCES SOUGHT SHALL STATE IF THEY ARE A SUPPLIER OR MANUFACTURER! What is the purpose of the item(s): An integral aquatic salt generator system to replace existing failed system. 45 CONS is interested in any size business that is capable of meeting this requirement. The government is also interested in all small businesses including (8(a), Historically Underutilized Business Zone, Service Disabled Veteran Owned Small Businesses (SDVOSB), or, if applicable based on NAICS code, Economically disadvantaged women-owned small business (EDWOSB) Women Owned Small Businesses (WOSB) that are interested in performing this requirement. The government requests interested parties submit a brief description of their company's business size (i.e. annual revenues and employee size), business status (i.e., 8(a), Historically Underutilized Business Zone, or SDVOSB, WOSB, EDWOSB, or small business) anticipated teaming arrangements, and a description of similar services offered to the Government and to commercial customers. Any responses involving teaming agreements should delineate between the work that will be accomplished by the prime and the work accomplished by the teaming partners. The Government will use this information in determining its small business set-aside decision." As stipulated in FAR 15.201, responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. No solicitation exists; therefore, do not request a copy of the solicitation. The decision to solicit for a contract shall be solely within the Government's discretion. Any information submitted by respondents to this sources sought synopsis is voluntary. This sources sought notice is not to be construed as a commitment by the Government, nor will the Government reimburse any costs associated with the submission of information in response to this notice. Respondents will not be individually notified of the results of any government assessments. The Government's evaluation of the capability statements received will factor into whether any forthcoming solicitation will be conducted as a full and open competition or as a set-aside for small businesses, or any particular small business designation (e.g. SDVOSB, HUBZone, 8(a), WOSB, VOSB, etc.). Commodity Capabilities package: All interested firms shall submit a capabilities package that explicitly demonstrates company capabilities-indicating examples of commercial sales-and product specifications related to this effort. Also indicate if you are the manufacturer, or provide the name and size of the manufacturer of the product(s) you will be supplying. Respondents are further requested to indicate their status as a Foreign-owned/foreign-controlled firm and any contemplated us of foreign national employees on this effort. Include in your capabilities package your DUNS, Cage Code, System for Award Management expiration date, GSA contract number and expiration (if applicable), and any related specifications/drawings. Responses may be submitted electronically to the following e-mail address: sandra.seman@us.af.mil and james.honeycutt.11@us.af.mil. RESPONSES ARE DUE NO LATER THAN 25 Mar 2016.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSC/45CONSb423/FA2521-16-Q-B011/listing.html)
- Place of Performance
- Address: 45 CONS, Patrick AFB, Florida, 32925, United States
- Zip Code: 32925
- Zip Code: 32925
- Record
- SN04054559-W 20160319/160317235650-8c6d0dcd9b31064f3e70ada6b39be92b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |