SOLICITATION NOTICE
66 -- Telementry Data Processing
- Notice Date
- 5/24/2016
- Notice Type
- Presolicitation
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Weapons Division, 429 E. Bowen Rd. Stop 4015 - CL, 575 'I' Ave, Bldg 36, Ste 1116 - PM, China Lake/Pt Mugu, California, 93555-6108, United States
- ZIP Code
- 93555-6108
- Solicitation Number
- N6893616T0236
- Archive Date
- 5/27/2017
- Point of Contact
- Erika Martin, Phone: (760) 939-0283, Faith L LaGore, Phone: (760) 939-0852
- E-Mail Address
-
erika.m.martin@navy.mil, faith.lagore@navy.mil
(erika.m.martin@navy.mil, faith.lagore@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- The Naval Air Warfare Center, Weapons Division, China Lake, CA intends to procure on an other than full and open competition basis the following items: 1) Model 3022P Portable "Lunchbox" integrated, Dual stream low latency telemetry decom. Qty 2 EA. Quoted item consists of 1) Portable/Rugged Lunchbox configured Telemetry Data Processing (TDP) system with assembly. Qty 1 EA. 2) PPCI 0-40 Mbps PCM Frame Sync/Decomprocessing module. Qty 2 EA. 3) IRIG Time Code/PCM Simulator Mezzanine. Qty 1 EA. 4) Tunable 40 MHz Advanced Digital PCM Bit SyncMezzanine - companion to 1612P, 1622P,1626P, 1611P, or 1602P PCI cards. Qty 1 EA. 5) PCI Data Distribution & Programmable DataStream Processor with Fiber Optic Output Port.Supports 64-bit I-Bus fed decom and timing data from up to eight independent Model 1612P decom input processing modules. Qty 1 EA. 6) Cable & Mount, adds 1612P Differential Twinax clk/data decom input. D-Sub connections provided for on spare PCI card slot connector panel. Qty 2 EA. 7) Cable & Mount, Diff PCM Simulator Clk / Data Output. D-Sub connections to "Octopus" Twinax terminated connectors. Qty 2 EA. 8) Hold-down Brackets. Rear panel "L" corner hold down brackets for securing the Model 3022P to cart or rolling platform to prevent tipping or movement during operation. Qty 2 EA. This requirement is sole sourced to Acroamatics Telementry Systems 5385 Hollister Ave, Bldg 5, Suite 102, Santa Barbara, CA 93111-2365 due to other manufactures hardward not being compatible with existing hardware. This is a direct replacement of existing equipment. Any firms believing that they can provide the materials may submit a written response to be received at the Contracting Office no later than 5 days after the date of publication of this notice. It must clearly show the firm's ability to be responsive without compromising the quality, accuracy or reliability of the materials without causing programmatic hardship. All responsible sources may submit a quotation which shall be considered by the agency. Respond to Erika Martin, by email erika.m.martin@navy.mil, fax to (760) 939-3095, or mail to Commander NAWCWD Code 254200D, Attn: Erika Martin, 429 E Bowen Ave, MS 4015, China Lake, CA 93555-6108. Quotations are preferred via email. Requirement is being advertised as sole source or competitive in accordance with FAR 6.302.1. All responsible sources must be registered in the System for Award Management (SAM) database at the following website: https://www.sam.gov/portal/public/SAM/. Written responses shall be submitted by e-mail to the point(s) of contact listed below or mailed to the Contracting Office Address listed below no later than 5 days from this notice date. Contractors must be certified through Defense Logistics Information Services (DLIS) in order to access Controlled Unclassified Information within FBO. See the DLIS website for registration details: http://www.dlis.dla.mil/jcp/.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/6c0896f489835ff21c717de1efdc9dc8)
- Record
- SN04126453-W 20160526/160524234040-6c0896f489835ff21c717de1efdc9dc8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)