Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 08, 2016 FBO #5311
SOLICITATION NOTICE

66 -- Beckman Agencourt AMPure XP system 60 mL - W81XWH16T0226

Notice Date
6/6/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
325413 — In-Vitro Diagnostic Substance Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Medical Research Acquisition Activity, U.S. Army Medical Research Acquisition Activity, Attn: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014, Maryland, 21702-5014, United States
 
ZIP Code
21702-5014
 
Solicitation Number
W81XWH16T0226
 
Archive Date
6/28/2016
 
Point of Contact
Kimberly S Hannan, Phone: 3016193490
 
E-Mail Address
kimberly.s.hannan.civ@mail.mil
(kimberly.s.hannan.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
COMBINED SYNOPSIS DOCUMENTATION This is a combined synopsis/solicitation for commercial items prepared in accordance with FAR 12.6, Streamlined Procedures for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; Quotes are being requested and a written solicitation will not be issued. The solicitation number is W81XWH16T0226. The solicitation is issued as a request for quotation (RFQ). Provisions and clauses in effect through Federal Acquisition Circular 2005-87 are incorporated. It is the contractor's responsibility to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses https://acquisition.gov/far/index.html and http://www.acq.osd.mil/dpap/sitemap.html. The NAICS code is 325413, with a small business size of 1,000 employees. This is a Full and Open Competition requirement; all qualified vendors are encouraged to submit a quote. USAMRAA on behalf of the United States Armed Forces Medical Examiner System (AFMES) requests responses from qualified sources capable of providing equipment brand name ore equal to the Beckman Agencourt AMPure XP system 60 mL (Part Number: A63881). BRAND NAME OR EQUAL SALIENT CHARACTERISTICS: In order to optimize the new PCR amplification and sequencing techniques required for AFDIL's applications, Beckman Coulter Inc. reagents are required. These reagents will result in less re-amplifications being required, conserving both sample and cost to the government. These improvements will allow for automation, reduction of analyst error, and reduction of overall processing time. During proof of concept and development of the next generation amplification and sequencing strategies, these reagents have been proven to the government to be: reproducible from lot to lot; robust; reliable; and free from human nuclear and mitochondrial DNA contamination. The vendor's ability to utilize quality controls that produce contamination free, reproducible and reliable libraries is essential for processing forensic casework samples and meets AFDIL mission requirements. Development and optimization of the new methodologies to identify missing individuals were performed using these reagents. These new methods are currently being forensically validated in accordance with the Federal Bureau of Investigations Quality Assurance Standards, which has resulted in the need for these items. Agencourt AMPure XP System 60ml (ManfllA63881); A PCR purification system that utilizes Solid Phase Reversible Immobilization (SPRI) magnetic bead-based technology for post-PCR clean up with no salt carryover. Requires no centrifugation or filtration; can be used in manual and automated 96- well formats. Must be compatible and validated for use with specific Next Generation Sequencing library preparation kits and instruments. •Must utilize Solid Phase Reversible Immobilization (SPRI) magnetic bead-based technology for post-PCR clean up. •Must NOT require centrifugation or filtration. •Must allow for manual and automated processing in both tube and 96-well plate formats. •Must enable high recovery of PCR amplicons as well as both double and single stranded DNA templates. •Must allow for a range of fragment sizes to be recovered greater than 1OObp. •Must remove unincorporated dNTPs, primers, primer dimers, salts and other contaminants. •Must generate purified PCR products that are stable at 4°C for minimum of 7 days. •Must have reagents with storage shelf life of 12 months. •Must be compatible and validated for use with the following kits, used for Next Generation Sequencing library preparation: oNextera XT (Illumina) oNEBNext Ultra (New England Biosciences) oNEXTflex DNA Sequencing Kit (BIOO Scientific) oAccel-NGS 1S DNA Library Kit for the Illumina Platform (Swift Biosciences)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/W81XWH16T0226/listing.html)
 
Place of Performance
Address: 115 Purple Heart Drive, Dover AFB, Delaware, 19902, United States
Zip Code: 19902
 
Record
SN04139241-W 20160608/160606234255-175d2e15f07f78a1db03dee2fb18d5ed (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.