SOLICITATION NOTICE
99 -- Remediation of Dioxin Contamination Project at Danang Airport, Vietnam - Justification and Approval (J&A)
- Notice Date
- 7/8/2016
- Notice Type
- Justification and Approval (J&A)
- NAICS
- 562910
— Remediation Services
- Contracting Office
- Agency for International Development, Overseas Missions, Thailand USAID-Bangkok, American Embassy/Bangkok, USAID Box 47, APO, 96546
- ZIP Code
- 96546
- Archive Date
- 8/6/2016
- Point of Contact
- Karittha Jenchiewchan, Phone: 66-2-257-3025, Daniel E. Harter,
- E-Mail Address
-
kjenchiewchan@usaid.gov, dharter@usaid.gov
(kjenchiewchan@usaid.gov, dharter@usaid.gov)
- Small Business Set-Aside
- N/A
- Award Number
- (AID-486-TO-12-00001-05)(AID-486-C-12-00002-04)(AID-486-C-13-00001-06)
- Award Date
- 7/7/2016
- Description
- Remediation of Dioxin Contamination Project at Danang Airport, Vietnam Joint J&A (3 awards) This request seeks the approval for extension and increase in the total estimated cost (TEC) for each of the the Environmental Remediation of Dioxin Contamination at Danang Airport Project in Vietnam Project contracts as follows: § Construction Management Contract (CMC): Construction Management and Oversight of the Environmental Remediation at Danang Airport Task Order (TO) number AID-486-TO-12-00001 with CDM Smith International Inc. (CDM Smith) under the Architectural, Engineering and Construction Services (A&E) Indefinite Quantity Contract (IDIQ) number AID-EDH-I-00-08-00023. The proposed modification is to: (1) raise the total estimated cost (TEC) by $6,615,000 from $13,281,600 to a new TEC of $19,896,600; and (2) extend the end of the period of performance (POP) from December 17, 2016 to o/a June 30, 2018. § Dig & Haul: Environmental Remediation at Danang Airport: Excavation and Construction contract (AID-486-C-12-00002) with Tetra Tech Incorporated (Tetra Tech). The proposed modification is to: (1) raise the TEC by $12,320,432 from $21,967,233 to a new TEC of $34,287,665; and (2) extend the end of the POP from December 11, 2016 to o/a June 30, 2018. § IPTD: In Pile Thermal Desorption Services for Environmental Remediation Project at the Danang Airport (AID-486-C-13-00001) with TerraTherm, Inc. (TerraTherm). The proposed modification is to (1) to raise the TEC by $11,632,423 from $36,783,235 to a new TEC of $48,415,658; and (2) to extend the end of the POP from March 31, 2017 to o/a June 30, 2018.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/42183c641b05f1c167d5d8c6a4f17d6d)
- Place of Performance
- Address: Danang, Vietnam, Viet Nam
- Record
- SN04177015-W 20160710/160708235259-42183c641b05f1c167d5d8c6a4f17d6d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |