DOCUMENT
65 -- AUTOREFRAC/KERATOMETER - Attachment
- Notice Date
- 8/3/2016
- Notice Type
- Attachment
- NAICS
- 339115
— Ophthalmic Goods Manufacturing
- Contracting Office
- Great Lakes Acquisition Center (GLAC);Department of Veteran Affairs;115 S 84th Street, Suite 101; WI 53214-1476
- ZIP Code
- 53214-1476
- Solicitation Number
- VA69D16N1104
- Response Due
- 8/8/2016
- Archive Date
- 11/6/2016
- Point of Contact
- Michael J Rosenthal
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential vendors, including Small Business, Veteran-Owned Small Business (VOSB), and Service-Disabled Veteran-Own Small Business (SDVOSB) vendors relative to the North American Industry Classification System (NAICS) Code 339115. The Iron Mountain VA Medical Center has a specific need for a refraction/keratometer shall feature accurate refraction measurement with large pupil zone imaging method, SLD and highly sensitive CCD, and optimal fogging to minimize accommodation. It shall also feature visual acuity measurement with glare test, simple opacity assessment with retro illumination image, patient friendly accommodation measurement, and keratometry measurement with mire ring. Unit shall contain the following technical specifications: ? Auto refractometer "Measurement range oSphere -30.00 to +25.00 D (VD = 12 mm) (0.01 / 0.12 / 0.25 D increments) oCylinder 0 to ±12.00 D (0.01 / 0.12 / 0.25 D increments) oAxis 0 to 180 ° (1 ° / 5 ° increments) oMinimum measurable pupil diameter ø2 mm ? Auto keratometer "Measurement range oCurvature radius 5.00 to 13.00 mm (0.01 mm increments) oRefractive power 25.96 to 67.50 D (n = 1.3375) (0.01 / 0.12 / 0.25 D increments) oCylindrical power 0 to ±12.00 D (0.01 / 0.12 / 0.25 D increments) oAxis 0 to 180 º (1 ° / 5 ° increments) "Sagittal measurement o25 º each from the center (superior side, inferior side, temporal side, nasal side) "VA measurement oMeasurement mode "Uncorrected VA, Corrected VA (distance, near) oMeasurement range "Less than 0.1, 0.1, 0.25, 0.32, 0.4, 0.5, 0.63, 0.8, 1.0, 1.25 or oLess than 20 / 200, 20 / 200, 20 / 80, 20 / 60, 20 / 50, 20 / 40, 20 / 30, 20 / 25, 20 / 20, 20 / 16 "Correction range oSphere -20.00 to +20.00 D (VD = 12 mm) (0.25 D increments) oCylinder 0 to ±8.00 D (0.25 D increments) oAxis 0 to 180 º (1 º / 5 º increments) ? Vision comparison "Available with visual acuity chart ? Retro illumination image ? Accommodation measurement range "0 to 10.00 D (0.01 / 0.12 / 0.25 D increments) ? PD measurement range "30 to 85 mm (1 mm increments) ? Automatic Corneal size measurement "(1 mm increments) (Near point PD: 28 to 80 mm at WD = 40 cm) 10.0 to 14.0 mm (0.1 mm increments) ? Automatic Pupil size measurement "1.0 to 10.0 mm (0.1 mm increments) ? Auto tracking / Auto shot "X-Y-Z directions "Auto shot ? Display "Tilt able 6.5-inch color LCD ? Printer "Thermal line printer with easy loading and auto cutter ? Interface "RS-232C (in / out), LAN, USB ? Dimensions "10.2 (W) x 19.5 (D) x 18.0 (H)" / 44 lbs. ? Must utilize a Super Luminescent Diode (SLD) and Multiple Pupil Zone Imaging method which improves the ability to measure patients with cataracts, IOL's and media opacities, and must be able to read pupil sizes from 2.0 to 6 mm. ? Must have the capability to read Cornea and Photopic and Mesopic pupil size measurements with the double ring technology. ? Must have auto eye tracking right, left, forward, back and auto read the measurements. Measuring time per eye is less than 0.3 seconds. Must be extremely user friendly. ? Must have target and target must use 1.5 diopters of fog to relax the accommodation for more accurate results. ? Must have quick mode for rapid eye movement patients. ? Must have reliability index numbers from 1-9 which appear after each reading on the printout indicating the confidence level of each reading (1 lowest - 9 highest). ? Range must be as follows: Sphere -30D to +25 diopters, Cylinder 0~ +/12 diopters Axis 0~180 degrees Axis - takes 180 individual measurements at each meridian and averages them. ? Must allow user to record unaided acuity and aided acuity. ? Must allow for sphere refinement. ? Must allow for comparison of objective measurement to a refined measurement for both distance and near. ? Must display cataract opacity images of the eye with retro illumination. ? Must be linked with auto lensmeters and electronic phoropter systems. ? Must provide low contrast testing. ? Must be able to conduct glare testing. ? Must have visual acuity chart. ? Must have subjective spherical refinement. ? Must compare glasses vs. AR reading. ? Must have unaided vision vs. AR reading. ? Must be able to conduct near vision testing. This is not a Request for Proposal or an announcement of a solicitation and no solicitation package exists at this time. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submittals will not be returned to the sender. The applicable North American Industry Classification System (NAICS) Code for this requirement is 339115 and the small business size standard is 500 employees. Responses due are to be submitted by e-mail to Michael J Rosenthal at Michael.rosenthal@va.gov. The information requested must be received no later than 2:00 pm Central Standard Time on Monday, August 8, 2016.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/VA69D16N1104/listing.html)
- Document(s)
- Attachment
- File Name: VA69D-16-N-1104 VA69D-16-N-1104.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2920143&FileName=VA69D-16-N-1104-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2920143&FileName=VA69D-16-N-1104-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA69D-16-N-1104 VA69D-16-N-1104.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2920143&FileName=VA69D-16-N-1104-000.docx)
- Place of Performance
- Address: Oscar G Johnson;VA Medical Center;325 East H Street;Iron Mountain, MI
- Zip Code: 49801-4760
- Zip Code: 49801-4760
- Record
- SN04207378-W 20160805/160803234902-1a64fbd161482929896d2b80faa2e930 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |