Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 19, 2016 FBO #5383
DOCUMENT

65 -- Ventilator - Columbia, MO VAMC - Attachment

Notice Date
8/17/2016
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street Trafficway;Leavenworth KS 66048
 
ZIP Code
66048
 
Solicitation Number
VA25516Q0832
 
Response Due
8/31/2016
 
Archive Date
9/30/2016
 
Point of Contact
Kevin Knight
 
E-Mail Address
worth,
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does no obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses. Email responses are preferred. Responses to this notice shall include: 1.Company Name 2.Address 3.Point of Contact 4.Phone, Fax, and Email 5.DUNS number 6.Cage Code 7.Type of business, e.g. Service Disabled Veteran Owned Small Business, Veteran Owned Small Business, 8(a), HUB Zone, Women Owned Small Business, SDB 8.Must provide a capability statement that addresses the organizations qualifications and ability to perform the work described below: The Harry S Truman VA Medical Center in Columbia, MO requires a new Critical Care Ventilator system. INVASIVE CRITICAL CARE VENTILATOR SPECIFICATIONS A. DESCRIPTION: Critical Care Ventilator, Complete An advanced ventilation unit for acute care respiratory support. High-performance invasive and non-invasive ventilation, comprehensive monitoring and therapy functions. Microprocessor driven, touch screen operation, audible and 360 degree viewable alarms, adaptable modes and controls, and trolley mounted for portability. MUST MEET OR EXCEED SALIENT CHARACTERISTICS BELOW: UTILITY REQUIREMENTS: Ventilator connection to the hospital's mains power supply with 100 to 240 V at 50/60 Hz. If mains power fails, operation is maintained via the internal battery Connections for hospital 50 psi gas supply for oxygen and medical compressed air. VENTILATOR REQUIREMENTS: 1. MODES: The following ventilator modes and functions must be present. Ventilation modes: Volume-controlled ventilation: - VC-SIMV - VC-AC - VC-CMV - VC-MMV Pressure-controlled ventilation: - PC-SIMV - PC-SIMV+ - PC-AC - PC-CMV - PC-APRV - PC-PSV Support of spontaneous breathing: - SPN-CPAP/PS - SPN-CPAP/VS Additional settings for ventilation: - Apnea Ventilation - Flow trigger - Inspiratory termination - Sigh - Automatic flow during volume ventilation - Volume Guarantee - Automatic tube compensation during both inspiration and expiration phases - APRV with autoset Tlow based % of peak expiratory flow - SmartCare therapy to allow automatic weaning of pressure support based on Co2, volume, and rate 2. PATIENT MONITORING AND ALARMS: Patient monitoring supported by the following alarm limit settings: - Maximum airway pressure Paw - Expiratory minute volume MVe - Measured inspiratory and exhalation volumes (VTi and VTe) - Calculated volume delivered in lung leak compensated (VT) - Calculated tidal volume per weight (cc/kg) - Spontaneous respiratory rate RRspon - End-expiratory CO2 concentration etCO2 -The inspiratory O2 concentration is monitored by automatically set limits. 3. DISPLAYS : Ventilator offers the following displays: - Curves - Graphic trends - Numeric trends - Loops - Alarm history - 7 day logbook of all events - Numeric parameters - Preconfigured lists for measured values and set values - Customized lists for measured values and set values 4. SPECIAL PROCEDURES: Ventilator must offer the following special procedures: - Manual inspiration/hold - Exp. Hold - Diagnostic functions: - Intrinsic PEEP measurement - Occlusion pressure measurement - NIF measurement - Manual disconnection - Medication nebulization - Low Flow PV Loop Therapy types: - Invasive ventilation (Tube) - Dedicated O2 Therapy mode that allows setting O2% and Flow rate - Non-invasive ventilation (NIV) 5. FUNCTIONAL SAFETY: - Omni directional alarm bar that allows visibility of alarms conditions 360 degrees - Hierarchical alarms that distinguish high, medium and low priority alarms- visually and audibly - Contextual help that allows quick identification of alarm conditions - Complete operator's manual accessible from the user interface - Message display window on ventilator housing that displays minute ventilation, o2 %, and breath bar 6. PERFORMANCE CHARACTERISTICS: -Control principle time-cycled, volume-constant, pressure-controlled -Intermittent PEEP duration 1 to 20 expiratory cycles -Medication nebulization for 5, 10, 15, 30 minutes -Endotracheal suction Disconnection detection automatic Reconnection detection automatic -Initial oxygen enrichment max. 3 minutes -Active suction phase max. 2 minutes -Final oxygen enrichment max. 2 minutes -O2 measurement (inspiratory side) -Paramagnetic sensor with no O2 cells to replace -Inspiratory O2 concentration (in dry air) - FiO2 Range 18 to 100 Vol% Accuracy ±3 Vol% at 20 °C (68 °F) -Drift of measurement accuracy 0.2 Vol% per month (the measured values are barometrically pressure compensated) -Battery life6 hours 3 hours with use of turbine -Preventative Maintenance1/year Any brand name specifications or proprietary functions are inadvertent. Substitutions and alternate solutions that will meet our patients' needs are highly encouraged. Response Needed by 8/24/2016 at 1200 EST. Contact Information: Kevin Knight Contracting Officer Department of Veterans Affairs Network Contracting Office 15 3450 S. 4th Street Leavenworth, KS 66048-5055 Office: 913-946-1979 Email: kevin.knight2@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25516Q0832/listing.html)
 
Document(s)
Attachment
 
File Name: VA255-16-Q-0832 VA255-16-Q-0832.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948621&FileName=VA255-16-Q-0832-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948621&FileName=VA255-16-Q-0832-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04228964-W 20160819/160817235743-dc4cffe9f086159b1d775413042a52e0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.