DOCUMENT
44 -- Electric steam generator- Danville - Attachment
- Notice Date
- 8/17/2016
- Notice Type
- Attachment
- NAICS
- 332410
— Power Boiler and Heat Exchanger Manufacturing
- Contracting Office
- Great Lakes Acquisition Center (GLAC);Department of Veteran Affairs;115 S 84th Street, Suite 101; WI 53214-1476
- ZIP Code
- 53214-1476
- Solicitation Number
- VA69D16N1187
- Response Due
- 8/22/2016
- Archive Date
- 11/20/2016
- Point of Contact
- Michael J Rosenthal
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential vendors, including Small Business, Veteran-Owned Small Business (VOSB), and Service-Disabled Veteran-Own Small Business (SDVOSB) vendors relative to the North American Industry Classification System (NAICS) Code 332410. The Danville VA Medical Center has a specific need for a new Electric Steam Generator. Vendor to supply a new Electric Steam Generator to the following specifications: Equipment: o180kW Electric Steam Generator (3ph 480 volt) oPressure vessel rated to lOOPSIG to ASME Section 1. oUL Listed Device. CSA Listed Device oNEC accepted wiring construction. oCapable of minimum 542 lbs/hr of steam generation at rated pressure. oInsulated Steel Pressure Vessel oOne (1) Sussman Model ES-180 180 kW Packaged Electric Steam Boiler, 542 LBS/HR, 480/3/60 lOOPSIG design oStainless steel sheathed heating elements & epoxy sealed terminals. oStandard Boiler Trim Including: NEMA 1cabinet, water level sight glass, drain/blowdown valve, ASME pressure relief valve pressure gauge c/w isolating stopcock, automatic reset electronic low water cutoff/ pump control, operating and high limit pressure controls, manual reset high pressure controller, backflow check valve and drain/blowdown valves, auxiliary low water cut-off included. oVentilated control panel including: main on/off switch, fused control circuit transformer, class "J" branch sub-circuit fusing, definite purpose magnetic contactors, step controller, on/off lights. oES38020A Water Feed Pump oES99335F Transformer oES81600-3 Automatic Blow Down Assembly oES100442 Sequencer oES89369 Vacuum Breaker oES94387 Manual / Auto Switch oES9363 Extra Dry Contacts (6) PER BOILER oES99113R Low Pressure Control Assembly oES99184 Surface Blowdown Valve Assembly oES103790 Steam Stop Valve Assembly 1-1/2N PT oWater Inlet: 1/2" NPT oSteam Outlet: 2"- N PT oDrain: 3/4" NPT with valve oTotal Amperage: 217 @ 480/3 Feedwater System: o180kW Electric Steam Generator to have dedicated pump/motor, sized for effective fill rate at operating pressure. o3- 120V/1PH/60Hz pumps/motors to meet existing lOOkW boiler demands of minimum 2.0gpm fill rate at operating pressure. Pump Model 105AERCT5-SS, 1h HP SS Regenerative Turbine Pump, 1/60/115V TEFC for installation to existing Boiler Feed system. oFeedwater control cabinet shall have dedicated HOA switches for each pump (4 total), a lOkW tank heater, 15% minimum oversized transformer from 6kVA rating, contactors, overloads, alarm audio/visual), and make up feed water circuit. oOne HEATER/PUM P CONTROL PANEL 460/3/60 to control oPanel to operate on individual Start Commands for each pump This is not a Request for Proposal or an announcement of a solicitation and no solicitation package exists at this time. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submittals will not be returned to the sender. The applicable North American Industry Classification System (NAICS) Code for this requirement is 332410 and the small business size standard is 500 employees. Responses due are to be submitted by e-mail to Michael J Rosenthal at Michael.rosenthal@va.gov. The information requested must be received no later than 2:00 pm Central Standard Time on Monday, August 22, 2016.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/VA69D16N1187/listing.html)
- Document(s)
- Attachment
- File Name: VA69D-16-N-1187 VA69D-16-N-1187.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948197&FileName=VA69D-16-N-1187-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948197&FileName=VA69D-16-N-1187-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA69D-16-N-1187 VA69D-16-N-1187.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948197&FileName=VA69D-16-N-1187-000.docx)
- Place of Performance
- Address: Danville VA Medical Center;1900 E. Main Street;Danville, IL
- Zip Code: 61832
- Zip Code: 61832
- Record
- SN04229160-W 20160819/160817235932-c3f0b3e84f5c35c5decaf60b3fb4568a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |