Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 19, 2016 FBO #5383
DOCUMENT

65 -- Myograph - Attachment

Notice Date
8/17/2016
 
Notice Type
Attachment
 
NAICS
541711 — Research and Development in Biotechnology
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street Trafficway;Leavenworth KS 66048
 
ZIP Code
66048
 
Solicitation Number
VA25516N0830
 
Response Due
8/22/2016
 
Archive Date
10/21/2016
 
Point of Contact
Keisha Reid
 
E-Mail Address
6-1983<br
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does no obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses. Responses to this notice shall include: 1.Company Name 2.Address 3.Point of Contact 4.Phone, Fax, and Email 5.DUNS number 6.Cage Code 7.Type of business, e.g. Service Disabled Veteran Owned Small Business, Veteran Owned Small Business 8.Must provide a capability statement that addresses the organizations qualifications and ability to perform the work described below: This RFI uses a Brand Name Description of the product required. All offers must work with existing equipment that has already been purchased and is currently in use at the station and also to meet standardization requirements throughout the hospital. Multi Myograph System The Research Service of the Harry S. Truman Memorial Veterans Hospital is requesting the procurement of a Danish MyoTechnology (DMT) Multi-Myograph system for the evaluation of vascular structure and function for the purposes of VA CDA-2 and Merit-funded projects at Harry S Truman Memorial Veterans Hospital. Multiple research programs at the Harry S Truman VA currently perform these analyses using a 4-channel DMT multi-myograph system purchased with ShEEP funds in 2013. This original system has proven invaluable for current labs in the Truman VA and, as such, has become heavily used. With the addition of several new cardiovascular research programs at this facility, however, scheduling conflicts between labs regularly arise for this equipment thus impeding data collection and research progress. Conflicts arise mainly since multiple channels are needed at one time for most day-long experimental designs therefore often precluding other labs from using the system. To resolve this problem we are requesting that a second 4-channel DMT multi-myograph system be procured to provide a total of 8 channels for experiments (including the existing 4 channel system). Acquisition of this system would enhance research efficiency, productivity, grant competitiveness, and our understanding of how vascular structure and function are altered in models of cardiovascular disease. Items Needed: Multi Myograph System (Item must be comparable to DMT's Multi Myograph System Model 620M, Product Code #100171) QTY: 1 "Include Multi Wire Myograph with four chambers allows the study of four vessels or tissue rings simultaneously "Allow for work requiring a higher throughput such as repetitive concentration-response curves "Include Jaw and pin supports to facilitate the use of a mix of small or large ring segments from 30 ?m (on jaw support) or to 450 ?m (on pin supports) "Allow segments to remain viable for >12 hours "Have built-in electrical heating, electronic valves for simultaneous rapid removal of buffer, analog output of force "Provide Automatic buffer filler system for semi-automated filling of all four chambers "Multi Interface specifications shall include: oForce range: User selectable at ±200/400/800/1600 mN oForce resolution: 0.1 mN oMicrometer: Manually operated oWeight calibration: Semi-automatic oHeating: Built into chamber, independent of super fusion oTemp. range: Ambient temp. to 45 °C oTemp. resolution: 0.1 °C oTemp. probe: External oOutput reading: Force (mN) oAnalogue output: Independently filtered 4-channel output at 2.5 V full scale oVoltage: 100-240 VAC (auto) 50/60 Hz via external power supply oAmbient temp.: 15-30 °C "Wire Myograph shall include: oVessel size: >30 ?m (jaw supports) o>450 ?m (pin supports) oChamber: Four individual chambers oChamber material: Acid-resistant stainless steel oChamber volume: Max. 8 ml oChamber suction: Manual or automatic, time controlled, user defined oChamber cover: Supplied with connections for gassing oChamber gassing: Individually controlled per chamber by needle valves Items Needed: AD Instruments PowerLab 4/35-Pro with LabChart softwarae DMT normalization module (Item must be comparable to DMT's Product Code #100039) QTY: 1 Items Needed: Automated Buffer Filling System (Item must be comparable to DMT's Automatic Buffer Filler System - 625FS Item # 100192) QTY: 1 oControl for semi-automated filling volume to 6 or 8 ml per chamber Items Needed: Additional Multi Myograph chambers (Item must be comparable to DMT product code #100169) QTY: 4 Items Needed: Force Transducer (Item must be comparable to DMT product code #100210) QTY: 4 Items Needed: Water bath incl. heater - 20L (Item must be comparable to DMT product code #100133) QTY: 1 Items Needed: Shielded BNC to BNC Cable - 3m (Item must be comparable to DMT product code #100054) QTY: 4 Items Needed: Stereomicroscope - Zeiss Stemi 305 A/CW/P/PP/FP/CP/CM/DC (Item must be comparable to DMT product code #100304) QTY: 1 Technical Specifications: o10X/23 br. foc. oEyepieces oStand N oLED 2-arm swan neck light source with focus attachments (Item must be comparable to DMT product code #100302) Items Needed: Desktop computer for software utilization/data collection/data analysis (Item must be comparable to Lenovo ThinkCentre Edge 72 3484) QTY: 1 Technical Specifications: oCore i5 3470S 2.9 GHz (Quad Core) oMinimum 4GB DDR3 SDRAM oIntel HD Graphics 2500 oMinimum 1 TB hard drive oDVD ±RW ( ±R DL) oWindows 8 Pro 64-bit oMinimum 21 in color monitor oIntegrated HD stereo audio oSlim USB keyboard and optical mouse Additional Information: Is there a maintenance requirement for this product: "No Preventive maintenance: "None Specific hook up requirements: "Electrical requirements, voltage requirements, (110/220 voltage) type of electrical plug (type of prongs): 115V, three-prong grounded plug - 5 outlets needed "Water supply requirements: N/A "Lab Gas Connection: N/A Training and Support: "None Installation: "None Response Needed by 8/22/2016 at 1200 PM CST Contact Information: Keisha Reid Contracting Specialist Department of Veterans Affairs Network Contracting Office 15 3450 S. 4th Street Leavenworth, KS 66048-5055 Office: 913-946-1983 Email: keisha.reid@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25516N0830/listing.html)
 
Document(s)
Attachment
 
File Name: VA255-16-N-0830 VA255-16-N-0830.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948055&FileName=VA255-16-N-0830-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2948055&FileName=VA255-16-N-0830-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Columbia VAMC;800 Hospital Drive, BLDG D218;Columbia, MO
Zip Code: 65201-5275
 
Record
SN04229251-W 20160819/160818000019-912d279323329ce7b6d1b49138dffbf5 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.