Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 28, 2016 FBO #5392
DOCUMENT

43 -- Replacement of Domestic Water Pumps for the CLC - Attachment

Notice Date
8/26/2016
 
Notice Type
Attachment
 
NAICS
333911 — Pump and Pumping Equipment Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
VA24216Q0975
 
Response Due
8/31/2016
 
Archive Date
9/30/2016
 
Point of Contact
Jacqueline Lewis
 
E-Mail Address
Jacqueline.Lewis@va.gov
(Jacqueline.Lewis@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. The Department of Veterans Affairs, James J. Peter VA Medical Center is currently conducting a market survey for qualified firms capable of providing "Constant Speed Water Booster Pumps " The purpose of this notice is to gain knowledge of potential qualified sources and their size classification//socioeconomic status (service-disabled veteran owned small business, veteran owned small business). This is a set aside for SDVOSB Responses to this notice will be used by the Government to make appropriate acquisition decisions. Responses to this notice should include: Company/individual name A service capability statement DUNS number Address Point of contact Social-economic category (ex: SBVOSB, VOSB). If your firm is a Service-Disabled Veteran Owned or Veteran Owned Small Business, you must be CERTIFIED in VetBiz (see internet site: http://vip.vetbiz.gov). Contractor must be registered in SAM (see internet site: http://www.sam.gov). Responses to this notice must be submitted in writing via email and received not later than August 31, 2016 at 9:00AM. Responses should be sent to Jacqueline.Lewis@va.gov Equipment requirements: Duplex Constant Speed Water Booster Replacement SYSTEM INFORMATION SYSTEM MODEL NO. DS-150-44 " SYSTEM CAPACITY 150 GPM " SYSTEM PRESSURE 64 PSIG " MINIMUM SUCTION PRESSURE 25 PSIG " MAXIMUM SUCTION PRESSURE PSIG " SYSTEM DIFFERENTIAL PRESSURE 39 PSI " SYSTEM POWER 460 VOLTS 3 PHASE 60 HERTZ PUMP INFORMATION PUMP NO 1 PUMP NO 2 PUMP NO 3 " PUMP TYPE End Suction EQUAL TO #1 NOT USED " PUMP MODEL CI 1506 " MOTOR HP 7.5 " MOTOR ENCLOSURE TEFC " RPM 3500 " DUTY POINT GPM 150 " TDH 102' " PRV OR CHECK VALVE SIZE 2.5" " PUMP SHUTOFF PSIG " MAX WORKING PRESS PSIG " MAXIMUM WORKING PRESSURE IS THE TOTAL OF THE MAXIMUM SUCTION PRESSURE PLUS PUMP SHUT OFF HEAD AND MUST NOT EXCEED THE ALLOWABLE WORKING PRESSURE OF THE COMPONENTS. STANDARD SYSTEM FEATURES SYSTEM OPTIONS VERTICAL SPACE SAVER DESIGN COMPLETELY PREFABRICATED INDIVIDUAL PUMP ISOLATION VALVES 304L STAINLESS STEEL MANIFOLDS PRV ON EACH PUMP THERMAL PURGE VALVES SYSTEM AND SUCTION PRESSURE GAUGES FACTORY TEST SYSTEM CONSTRUCTION MANIFOLD SIZE 4 " CONNECTIONS FLANGED CONFIGURATION RIGHT HAND SYSTEM DIMENSIONS AND DRY WEIGHT L 40 " x W 32 " x H 65 " WT 800 # HYDRO-PNEUMATIC TANK TANK LOCATION MODEL FXA400 106 GALLONS 125# ASME INTERMITTENT LEAD PUMP OPERATION 0 to 150 GPM PUMP 1 o PRESSURE SWITCH PUMP SEQUENCING STANDARD CONTROL PANEL FEATURES UL LISTED ENCLOSED INDUSTRIAL CONTROL PANEL NEMA 1 ENCLOSURE MAGNETIC STARTERS WITH 3 LEG OVERLOAD PROTECTION PROGRAMMABLE LOGIC CONTROLLER (PLC) PUMP RUNNING LIGHTS H/O/A SELECTOR SWITCHES 115 VOLT FUSED CONTROL CIRCUIT TRANSFORMER PUMP MINIMUM RUN TIMING AUTO ALTERNATE EQUAL PUMPS MOUNTED AND WIRED ON SKID PUMP OPERATING AND SEQUENCE CONTROLS CONTROL PANEL OPTIONS CONTROL POWER (ON-OFF) SWITCH AND LIGHT INDIVIDUAL DISCONNECTS WITH EXTERNAL HANDLES AND FUSING LOW SUCTION PRESSURE ALARM AND SHUTDOWN WITH AUTO RESET AND INDICATION LOW SYSTEM PRESSURE ALARM TO START STANDBY PUMP(S) WITH MANUAL RESET AND INDICATION HIGH SYSTEM PRESSURE ALARM AND SHUTDOWN WITH MANUAL RESET AND INDICATION AUDIBLE ALARM WITH SILENCE PUSH BUTTON If you are able to provide the above, specifically, please respond in the affirmative, prior to Wednesday 8/31; 9AM Eastern time. Your company must also be authorized to provide the equipment. Verification of authorization may be requested. Note that you must be verified in Vetbiz.gov as a veteran or Service disabled veteran small business, as this would be a set aside.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24216Q0975/listing.html)
 
Document(s)
Attachment
 
File Name: VA242-16-Q-0975 VA242-16-Q-0975.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2970784&FileName=VA242-16-Q-0975-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2970784&FileName=VA242-16-Q-0975-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04242881-W 20160828/160826234721-ef56b676852ea397f741bce874875890 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.