DOCUMENT
66 -- Urinalysis analyzer system - Cost Per Test - Attachment
- Notice Date
- 9/7/2016
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Palo Alto Health Care System (90/NCA);3801 Miranda Ave;Palo Alto CA 94304-1207
- ZIP Code
- 94304-1207
- Solicitation Number
- VA26116Q0949
- Response Due
- 8/18/2016
- Archive Date
- 8/28/2016
- Point of Contact
- carol.lam@va.gov
- E-Mail Address
-
carol.lam@va.gov
(carol.lam@va.gov)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice in conjunction with procedures in FAR Part 13. This announcement constitutes the only solicitation. This proposed contract action is for supplies or services for which the Government intends to solicit and negotiate with only one source under the authority of FAR 13.106-1(b)(1). Interested persons may identify their interest and capability to respond to the requirement or submit price quotations. This notice of intent is not a request for competitive price quotations. However, if there are two or more Service-Disabled Veteran-Owned Small Business (SDVOSB) and Veteran-Owned Small Business (VOSB) who are capable of providing a quote at a fair and reasonable price, this acquisition will be set aside for SDVOSB/VOSB. Unverified SDVOBs or VOSBs are considered non-responsive and price quotations will not be evaluated. To qualify, vendor must be authorized dealer of Beckman Coulter Urinalysis analyzer system. A letter from the manufacturer stating your company is an authorized dealer must be in possession by the due date and be available for submission, if requested. The solicitation number, VA261-16-Q-0949 has been assigned as a Request for Quotation (RFQ). This document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-89 effective August 15, 2016 and Veterans Affairs Acquisition Regulation Supplement (VAAR) current to January 7, 2010. Interested persons may identify their interest and capability to respond to the requirement or submit a price quotation. The North American Industry Classification System (NAICS) Code for this acquisition is 334516, size standard 1000. Description of Requirements: The Iris IQ200 Elite automated urinalysis system is composed of an integrated urinalysis chemistry strip reader Velocity Automated Urine Chemistry Analyzer and a fully automated urine microscopy analyzer (Iris IQ200). The Iris IQ200 performs microscopic analysis using a flow cell and a digital microscope with pattern recognition software to properly identify and quantify cells or particles in urine. All images are stored for rapid retrieval if there is a questionable cell or particle that requires classification. 1.DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK 1.1.SCOPE OF PROCUREMENT: 1.1.1.The desired instrumentation shall have the capability of performing or reporting the clinical parameters as by San Francisco VA Medical Center. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile as described below meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). 1.1.2.Equipment must maintain, or preferably reduce the number of work stations or overall labor required to accomplish the required testing by each laboratory. 1.1.3.The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. 1.1.4.Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor's equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor's equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. Performance Period is One (1) + four (4) option years Only email received directly from the requester are acceptable. Email to carol.lam@va.gov no later than Tuesday, September 13, 2016. Receipt must be acknowledged on my desktop computer to be recognized as received. This is the only acceptable method for delivery of quotes.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAPAHCS/VAPAHCS/VA26116Q0949/listing.html)
- Document(s)
- Attachment
- File Name: VA261-16-Q-0949 VA261-16-Q-0949 CSS.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2991409&FileName=VA261-16-Q-0949-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2991409&FileName=VA261-16-Q-0949-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA261-16-Q-0949 VA261-16-Q-0949 CSS.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2991409&FileName=VA261-16-Q-0949-000.docx)
- Record
- SN04260019-W 20160909/160907235513-f2c4605289f0743d3b6681d1cdac62d2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |