Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 14, 2016 FBO #5409
DOCUMENT

C -- 612-16-2-6101-0017 - (2) Boiler Plant Operators - Attachment

Notice Date
9/12/2016
 
Notice Type
Attachment
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Northern California HealthCare System;150 Muir Road;Martinez CA 94553-4668
 
ZIP Code
94553-4668
 
Solicitation Number
VA26116Q1224
 
Response Due
9/15/2016
 
Archive Date
9/16/2016
 
Point of Contact
Jason T. Hill
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT NOTICE - This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. No contract will be awarded as a result of this Sources Sought announcement. The Department of Veterans Affairs (VA), Network Contracting Office (NCO 21) is soliciting information from qualified Small Business sources, the results of this announcement will be evaluated to determine if at least two SDVOSB or VOSB sources are capable of performing the proposed work. The Department of Veterans Affairs (VA), Network Contracting Office (NCO 21) seeks responses from Small Business Vendors that possess the capability and experience required to database support for the VA's PICIS database. The following general description outlines contractor requirements. Provide two (2) full-time Boiler Operators, each shift must have (2) Boiler Operators at all times, shifts rotate around 24/7 schedules to include holidays for the operation of the facility Energy Center within the VANCHCS-SVD located at the Mather VA Hospital. Contractor independently operates and maintains utility plant equipment and systems with minimal supervision; maintain one or multiple gas/propane fired water or fire tube boilers equipped with electronic controls, and associated auxiliary control equipment; operate a boiler feed water treatment plant and test the water, adding proper chemicals to boiler feed water if necessary. Contractor must possess the ability to perform the common tasks associated with journeyman duties, and will be subject to occasional and random inspections. Observe boiler controls, gauges and charts to make necessary adjustments for proper fuel and airflow to maintain system pressure. Operate the air conditioning management system consisting of an automatic data system for gathering and recording plant and remote air conditioning data. Ability to do the common tasks associated with journeyman duties in a line of work, under close supervision and subject to inspection at the end of each task. Read and record temperatures, pressures, and operating data as required within a boiler pant. Must be able to competently to inspect: all boiler controls, combustion equipment, water leveler regulation, steam regulators, 0-2 recorder, automatic 0-2 trim systems, safety devices, instruments, flow meters, feed pumps, gas regulators, automatic controls and air regulators. Maintain constant observation of the meters, charts, gauges, water levels and temperatures to ensure that all systems are functioning properly. Read and record temperatures, pressures, and operating data as required within a boiler plant. Must have knowledge of equipment assembly, installation repairs; must be able to perform repairs on boilers, chillers and related equipment, such as replacing bearings, packing and mechanical seals in pumps both liquid transfer and vacuum. Install and maintain all auxiliary air conditioning equipment consisting of chill water pumps, glycol circulating pumps, cooling towers, control air compressors, refrigerated /desiccants type air-dryers, pneumatic/electric control valves, variable frequency drives, digital pneumatic variable air volume boxes, electronic air filters, electric/steam humidifiers, automatic/manual water treatment systems, exhaust fans, air-balancing accessories. Perform minor steam fitting, plumbing, electrical work, painting, and housekeeping of the boiler plant. Ability to interpret instructions, specifications operating procedures: Determine proper chemicals to be added to the water in the proper proportions in which they are to be added to prevent corrosion and scale formation. Add chemicals to the chiller system and record test results and chemicals added. Perform adjustments and corrections to boilers based on recorded inspection date. Respondents shall provide detailed information as to how they are qualified to perform this work. In addition, respondents are requested to submit the following information: (1) Name of Organization, (2) Address + Zip Code, (3) Telephone number, (4) current GSA contract number, (5) Business status: (DVOSB or VOSB only) (6) Point(s) of contact, (7) e-mail address, (8) DUNS number, (9) number of years' experience in providing this service, (10) current and/or past performance references that identify the contract/order number, customer, contract value, period of performance, prime or subcontract, and a brief description of services provided under the contract/order number. Interested vendors shall notify the Contracting Officer of pending changes in business status. Respondents will not be notified of the results. Based on the responses received, the Contracting Officer reserves the right to determine the set-aside status. No reimbursement will be made for any cost associated with providing information in response to this solicitation. All responses must be submitted by e-mail to the point of contact identified below; no other method of transmittal will be accepted. Responses to this Sources Sought Notice shall be e-mailed to the Contracting Specialist, Jason Hill, at Jason.hill@va.gov. Responses must be received no later than 2:00 PM PST on September 15, 2016. Failure to submit all information requested will result in a contractor not being considered as an interested business.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26116Q1224/listing.html)
 
Document(s)
Attachment
 
File Name: VA261-16-Q-1224 VA261-16-Q-1224.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2999838&FileName=VA261-16-Q-1224-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2999838&FileName=VA261-16-Q-1224-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Sacramento VAMC - Mather;Mather, CA
Zip Code: 95655-4200
 
Record
SN04266344-W 20160914/160912234544-311830fa86a423e2cc42b9d54eba953e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.