DOCUMENT
52 -- Chlorine Analyzer - Attachment
- Notice Date
- 9/14/2016
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 20;960 Broadway Ave, Suite 460;Boise ID 83706
- ZIP Code
- 83706
- Solicitation Number
- VA26016N0958
- Response Due
- 9/19/2016
- Archive Date
- 9/20/2016
- Point of Contact
- CRAIG WAGSTAFF
- E-Mail Address
-
craig.wagstaff@va.gov
(craig.wagstaff@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential Vendor Information Pages (VIP) Verified (www.vip.vetbiz.gov) Service Disabled Veteran Owned Business (SDVOSB) or Veteran Owned Business (VOSB) sources which can provide the following equipment: CHLORINE ANALYZERS FEATURES o EPA 334.0 Compliant o Reagent free measuring o Complete panel system allows for quick and easy installation o Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure o Pre-wired panel includes a 100/240 VAC power supply, two 4 to 20 mA outputs and two mechanical relays o Optional automatic pH compensation "General oCompatible 3-2630-1 Free Chlorine Electrode, 0 to 2 ppm / 3-2650-7 Amperometric Electronics o3-2630-2 Free Chlorine Electrode, 0 to 5 ppm / 3-2650-7 Amperometric Electronics o3-2630-3 Free Chlorine Electrode, 0 to 20 ppm / 3-2650-7 Amperometric Electronics oSignet 3-2724-00 Flat pH Electrode, 0 to 14 pH/ 3-2750-7 pH Sensor Electronics "Materials oPanel Black Acrylic oFlow Cell Acrylic oWiring Enclosure Polycarbonate "Wetted Materials oFlow Cell, Spacer Rings Acrylic oFlow Regulator Housing Polycarbonate oStrainer, E-clip, Regulator Spring, Float Stainless Steel oValves, Vent Polypropylene oFlow Cell O-rings, Diaphragm EPDM, FKM oChlorine Electrode PVC, PVDF, FPM opH electrode PPS, Glass, UHMW PE, FPM oSealing Tape on Valves, Plug and Vent PTFE oPlug Polyethylene "Max. Temperature/Pressure Rating oSystem Inlet Pressure Rating 1 to 8 bar 15 to 120 psi oPressure Regulator < 0.69 bar (10 psi) variation over all ranges of flow and pressure oFlow Tolerance ± 15% or rated specification above oFlow Rate Limits 30.24 to 45.36 LPH 8 to 12 US gal/h oStorage Temperature 0 °C to 65 °C 32 °F to 149 °F oOperating Temperature 0 °C to 45 °C 32 °F to 113 °F "Electrical oAC Input - Standard Configuration 100 to 240 VAC nominal 50 to 60 Hz, 0.17 A at 100 VAC oDC Input - Optional Configuration 12 to 24 VDC ±10% regulated, 250 mA max. "Environmental oRelative Humidity 0 to 95% oMaximum Altitude 2000 m (6,562 ft) oEnclosure NEMA 4X (with output wire glands sealed) Potential SD/VOSB's having the capabilities necessary to provide the above stated equipment are invited to respond to this Sources Sought Notice via e-mail to Craig Wagstaff at craig.wagstaff@va.gov no later than September 19, 2016. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, and e-mail address; suggested equipment information including manufacturer, model and delivery schedule; whether system is presently offered on a current GSA Federal Supply Schedule contract. NAICS Code 334516 is applicable to determine business size standard. Any questions or concerns may also be directed to Craig Wagstaff via e-mail. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BoVAMC531/BoVAMC531/VA26016N0958/listing.html)
- Document(s)
- Attachment
- File Name: VA260-16-N-0958 VA260-16-N-0958.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3002868&FileName=VA260-16-N-0958-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3002868&FileName=VA260-16-N-0958-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA260-16-N-0958 VA260-16-N-0958.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3002868&FileName=VA260-16-N-0958-000.docx)
- Place of Performance
- Address: BOISE VA MEDICAL CENTER;500 W. FORT STREET;BOISE, ID
- Zip Code: 83702
- Zip Code: 83702
- Record
- SN04272078-W 20160916/160914235739-e0bfe19d2b23163dd3dae15065e6f84d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |