Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 24, 2016 FBO #5480
DOCUMENT

45 -- DAS Software and Opacity Monitors - Attachment

Notice Date
11/22/2016
 
Notice Type
Attachment
 
NAICS
332410 — Power Boiler and Heat Exchanger Manufacturing
 
Contracting Office
Department of Veterans Affairs;VAMC White River Junction;215 North Main Street;White River Junction VT 05009
 
ZIP Code
05009
 
Solicitation Number
VA24117Q0049
 
Response Due
11/29/2016
 
Archive Date
12/14/2016
 
Point of Contact
Mary K. (Kathy) Bosch
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The West Haven VA Medical Center is soliciting for DAS Software and Opacity Monitors to be removed, purchased, and installed at the West Haven VA Medical Center in Connecticut. Please see attached Request for Quotation VA241 17 Q 0049. This procurement is set aside for SDVOSB. DEPARTMENT OF VETERANS AFFAIRS STATEMENT OF WORK BOILER PLANT BLDG.-16 WEST HAVEN, CONNECTICUT 950 CAMPBELL AVE. EMERGENCY REPLACEMENT OF OPACITY MONITORING SYSTEM Introduction; To replace three (3) opacity monitors, and one (1) data acquisition (recorder) system, due to recorder and opacity monitor failed. Background; 1999,-VACTWH received a notice of violation #14241 and a fine was proposed. In lieu of execution of the fine VACTWH was to replace the failed monitors and develop an ongoing QA/QC plan to meet specifications of 40CFR60, Appendix A-B, Performance specification 1, Opacity monitors used for compliance and 40CFR60, Appendix, F, ongoing QA/QC procedures for Opacity monitors. 2015,- Yokogawa Model-3500 Hybrid recorder was taken out of service due to failed- no parts to repair it, a temp unit was put in its place (report made to the state of CT DEP about it ). 2016, - Opacity monitor failed- no parts to repair (report made to state of CT DEP about it). Old monitors are not entire changeable, old system cannot support new updated equment. Scope; To remove and reinstall three (3) Opacity monitors, and one (1) data acquisition (recorder) system, three (3) blower systems for Opacity monitors, and all software and configured integration to system, provide all labor and equipment to install, test, and provide all documentation prior to, during, and after for EPA, CT DEEP, and VA standards. To provide training, and instruction materials to VA staff. NC01 Contracting POC is Mary K. (Kathy) Bosch at 802-296-5114.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/WRJVAMROC/DVAMROC/VA24117Q0049/listing.html)
 
Document(s)
Attachment
 
File Name: VA241-17-Q-0049 VA241-17-Q-0049_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3123635&FileName=VA241-17-Q-0049-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3123635&FileName=VA241-17-Q-0049-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: White River Junction VAMC;215 North Main Street;White River Junction, VT
Zip Code: 05009-0001
 
Record
SN04334401-W 20161124/161122234541-982679f35b2c00cbd84572ee64d2a2a3 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.