Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 14, 2016 FBO #5500
SOURCES SOUGHT

Y -- Removal and replacement of medium voltage cables at Barkley

Notice Date
12/12/2016
 
Notice Type
Sources Sought
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Nashville, Attn: CELRN-CT, PO Box 1070, Nashville, Tennessee, 37202-1070, United States
 
ZIP Code
37202-1070
 
Solicitation Number
W912P5-17-S-0003
 
Archive Date
1/14/2017
 
Point of Contact
Kristal R Jones, Phone: 615-736-7916
 
E-Mail Address
Kristal.R.Jones@usace.army.mil
(Kristal.R.Jones@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The Government is issuing this Sources Sought Notice to determine a competitive basis. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey. This questionnaire is for market research purposes only. Only contractors capable of performing this type of work should respond to this notice. Requirement The U.S. Army Corps of Engineers (USACE), Nashville District, anticipates soliciting a requirement for a firm fixed price construction contract to remove and replace the existing medium-voltage cables for each of the four (4) generating units at the Barkly Power Plant, Kuttawa, KY, with new 15kV MV-105 cables and associated Class 1A terminations. The estimated magnitude of this project is between $1,000,000 and $5,000,000. The types of work and skill sets for this requirement are as follows: a)Modification, installation, termination, and testing of medium-voltage (greater than 480V to 35kV) power house bus work and cables; b)Dissemble and removal of medium voltages cables and associated Class 1C terminations; c)Procurement and installation of 15kV MV-105 cables and associated Class 1A terminations; d)Procurement and installation of temporary 15kV Feeders complete with cable tray and supporting system; e)Installation of control system and alarms in control rooms and machinery areas to include items such as digital/analog controls, meters and human/machine interface systems; f)Development of asbestos abatement plans associated with power plant cable systems and abatement of asbestos in accordance with approved plans; g)Development of environmental mitigation plan for oil and lead removal; h)Procurement and/or manufacture and installation of custom electrical control panels; i)Perform special factory and special field tests of new cable systems. The anticipated NAICS code is 237130, Power and Communication Line and Related Structures Construction, with a small business size standard of $36.5 million in annual receipts. Survey The Government is issuing this notice to determine a competitive basis. This is not a solicitation and the items listed herein are subject to change or eliminated from the requirement. This questionnaire is for market research purposes only. Only contractors capable of performing this type of work should respond to this notice. Your response to this survey is requested by Friday, December 30, 2016 at 4:00 p.m. Central Standard Time (CST). All information MUST be submitted by e-mail to Contract Specialist Kristal Jones at Kristal.R.Jones@usace.army.mil or by fax to 615-736-7124. 1.Name of your firm: 2.CAGE: 3.Point of Contact, Phone number and EMAIL address: 4.Please list three (3) medium (greater than 480V to 35kV) or high voltage (35kV to 230 kV) cable replacement jobs successfully completed, similar to the above referenced type of work. If possible, provide projects that cover the most skill sets listed above preferably at power generation facilities. Examples must be from projects in which your firm was the prime, or sub-contractor, and in which your firm performed at least 50% of the construction work. Examples must have been completed within the last eight (8) years. a. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: b. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: c. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: 5.Are you a Small Business classified under the above NAICS code? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)? 6.If your company is a small business concern, per FAR 52.219-14, at least 25 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. Can your firm be expected to do this, given your current employee situation? (Please respond yes or no.) 7.If this requirement is advertised, do you anticipate submitting a proposal? 8.Please provide any additional information you feel is necessary:
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA62/W912P5-17-S-0003/listing.html)
 
Record
SN04349255-W 20161214/161212234344-529c8898fe7c5eb3f34ffbc1b12d67f0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |