Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 02, 2017 FBO #5578
MODIFICATION

66 -- Freestanding Laboratory Glassware Washer/Dryer

Notice Date
2/28/2017
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
CPOD US Environmental Protection Agency 26 West Martin Luther King Drive Mail Code: NWD Cincinnati OH 45268 USA
 
ZIP Code
00000
 
Solicitation Number
RFQ-OH-17-00086
 
Response Due
3/15/2017
 
Archive Date
9/15/2017
 
Point of Contact
Loesch, Kimberly
 
Small Business Set-Aside
N/A
 
Description
The purpose of amendment 1 to the Notice of Intent to Sole Source is to fix incorrect characters that posted to FedBizOpps. The U.S. EPA intends to negotiate on a sole source basis, under the authority of FAR 13.106-1(b)(1)(i), with Lancer Sales U.S.A., Inc. to purchase a Lancer 1600 LXP Freestanding Glassware washing machine and dryer. The freestanding laboratory glassware washing machine is a replacement for an existing unit. It will be installed in the existing space of the old unit. The machine will be used for washing and drying various types and sizes of laboratory glassware including, but not limited to, beakers, test tubes, Erlenmeyer flasks, volumetric flasks, and graduated cylinders. The following minimum required specifications must be met in order to meet the needs of the EPA: *Must be able to safely wash/dry standard lab ware made of plastic, glass, and metal. *The wash chamber shall be constructed of stainless steel. *The unit shall have an insulated single door. *The unit shall be recessed through a single wall. Unit size must be such that it fits and can be installed in the existing wall hole of 75.75 inches high by 43 inches wide. *The unit shall not exceed a front to back depth of 39 inches. This shall include extending no further than 27 inches as measured from outer wall face to the rear of the unit and 12 inches as measured from the outer wall face to the front of the unit. *Unit must fit through existing access doorway of 40 inches wide x 85 inches tall clearance. *Capable of operating using the available 50 psig steam supplied by the building *Must be able to operate using building supplied potable hot and cold water at a pressure between 30 and 50 psig * Must be able to operate using building supplied purified (DI) water at a pressure between 30 and 50 psig. *The electricity requirement must not exceed 208/240 VAC, 60 Hz, 3-phase power *Must be configured for floor drain discharge. *Must include a drain discharge cool down system to cool wastewater to less than or equal to 60 °C upon discharge. *Vented drying system capable of drying glassware using HEPA filtered, heated air up to at least 110 °C that includes injection drying and adjustment to lower drying temperatures for heat sensitive materials. *Must be able to automatically dose detergent from a reservoir/container located inside the unit. *Must be able to automatically dose an additional chemical agent such as rinse aid or acid rinse. *Must include filters to protect the chamber recirculation and drain pump(s). Filters must be readily user removable and capable of being cleaned by the user. *Must feature a control system that has the ability to create and store at least 10 programmable cycles, of which at least 5 must be user customizable/editable. *Must include an emergency stop button that will cease the unit's function in the event of a malfunction *Must include an interlock/safety switch that ceases unit operation immediately upon opening of door and prevents cycle startup when door is open. *Basic accessories such as racks, baskets and headers that are recommended for laboratory glassware including, but not limited to: 1 basic/general purpose basket with lid; 2 racks with long jets/ports for cleaning long/tall glassware; and 1 rack with a combination of short and long jets for cleaning a combination of glassware sizes. *Manufacturer must have trained service professionals available within the Cincinnati, Ohio metropolitan area. *Quote must include and specifically list the cost of professional installation of washer to include all necessary labor and materials required to assemble equipment including utility connections to the unit and any necessary operational check testing following set up including any necessary adjustments. *Unit must include a 1 year minimum warranty. The EPA has identified Lancer Sales U.S.A., Inc. as the only contractor able to meet the minimum specifications. Lancer Sales U.S.A., Inc. is the only contractor that offers a freestanding laboratory glassware washer and dryer that: (1) can be installed in the existing wall hole of 75.75 inches high by 43 inches wide; and (2) includes an emergency stop button that will cease the unit's function in the event of a malfunction. None of the other equipment identified during market research met all of these requirements. This procurement will be accomplished under FAR Part 12 and FAR Part 13 Procedures. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTATIONS. Any firm that is capable of meeting EPA's requirement as set forth above may submit a response; which, if received within fifteen (15) calendar days of the date of this announcement, will be reviewed for consideration. A determination not to compete the described requirement based upon responses to this notice is solely within the discretion of the Government. Responses to this posting must be submitted via the FedConnect website at https://www.fedconnect.net through the message center for RFQ-OH-17-00086. Mail, fax, phone and email submissions shall not be accepted. One or more of the items under this acquisition is subject to Free Trade Agreements. EPA anticipates that award will be made by March 28, 2017.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/EPA/OAM/OH/RFQ-OH-17-00086/listing.html)
 
Record
SN04416701-W 20170302/170228234403-ab4e0f1fbb86da23c0ea3d18038df002 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)