Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 09, 2017 FBO #5677
DOCUMENT

54 -- OR Management System - Attachment

Notice Date
6/7/2017
 
Notice Type
Attachment
 
NAICS
541519 — Other Computer Related Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
 
ZIP Code
23667
 
Solicitation Number
VA24617Q0806
 
Archive Date
7/7/2017
 
Point of Contact
Audrey Wooten
 
E-Mail Address
audrey.wooten@va.gov
(audrey.wooten@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The purpose of this Amendment the statement of work and price schedule as followed for RFQ VA246-17-Q-0806 Combined Solicitation. Brand name or equal clause is removed. Vendors MUST meet all requirements stated in Statement of work and items in price schedule. VAMC Salisbury STATEMENT OF WORK Surgical Workflow Solution 1.0 BACKGROUND The VAMC Salisbury, 1601 Brenner Avenue Salisbury, NC 28144 requires a Surgical Workflow Solution; capable of interfacing with patients and family members, providing real time information on patient status and an overall improvement in customer care and experience. This solution will automate surgical workflow and use analytics to measure, analyze, and deliver patient safety and Operating Room (OR) efficiency data. Additionally, this solution will provide perioperative staff members and surgical team s awareness of patient, equipment, and operating room status throughout the course of patient care. The intent of this solution is to identify delays in getting patients through the perioperative process so that efficiencies and increased patient safety can be realized and to increase visibility into the surgical workflow by staff, patients and family members. 2.0 SCOPE VA intends to award a single Delivery Order, Firm Fixed Price to a contractor capable of providing the outlined Surgical Workflow Solution System & supporting ancillary services; the associated installation and configuration services, as well as the incorporated staff training requirement. 1. This requirement will consist of a software/application solution, reporting/analytics capabilities, compatible server system and supporting software, dash board workstations and the ability to interface with the existing systems and must demonstrate the performance capabilities detailed throughout this document. A Turn-Key Installation providing all services, training, hardware, cables and accessories for a complete and functional system. All software applications and servers must be approved by the National Intake Group. Physician mobile app: for surgeons to stay continuously informed of patient workflows, exceptions, delays, cancellations and automatic notification. OR charge mobile tablet: continuously updated each day with patient workflows, staffing, exceptions and delays, on demand data analytics. Auto notifications: automatically capture patient arrivals to OR and instantly notify surgeons and key surgical staff. Instant web-based visibility at bedside PC: continuous patient visibility and communication to OR, Pre and Post Op staff. Pre/Post Op care-boards: continuous patient visibility and updates to surgeons and staff via large format displays located in Pre/Post Op areas, OR control desk and staff lounges. Monitors 55 LED Display LCD TV 1080p (full HD) Command center: continuous patient visibility and communication to physicians, management and staff. Staffing solutions: electronic staffing boards assignments posted for OR rooms, breaks and relief a. Contract Duration: The base contract period is one (1) year from date of contract award. b. Place(s) of Performance: VAMC Salisbury 1601 Brenner Ave Salisbury, NC 28144 c. Hours of Operation. VA site-representative(s) or Contracting Officer Representative(s) (COR) will establish a window of time in which access and requirement performance will be authorized in accordance with the conditions outlined with this SOW. 3.0 TECHNICAL REQUIREMENTS The following technical specification requirements are set forth for the Surgical Workflow Solution: b. Application Requirements. The application solution shall: 1. Provide Perioperative scheduling package that will interface with VistA surgery scheduling package. Provide the ability to load special equipment in the system for selection when scheduling case. 2. Provide HIPPA compliant, real-time patient status to operating room staff providing streamline transition of patients as they move throughout the perioperative suite, capturing progress along every point of the process and communicating relevant updates to the physicians, nurses and families via highly visible displays. Provide accessibility by authorized staff via smart phones/tablets. Provide HIPPA compliant updates to family s email/text. 1. Collect procedure specific data (start/stop times, anesthesia times, room open/room closed, first case starts, turnaround time, OR utilization, OR block time, overtime, out of block utilization, surgeon/anesthesia arrival time). 2. Provide technology designed to provide the OR team with real-time, accurate patient data from various hospital sources (lab, radiology, EMR.). 3. Collect data required by the Surgical Complication Improvement Project (SCIP) and VA's National Surgical Quality Improvement Project (VASQIP). Data will be collected by the system but then reported by VA in to SCIP and VASQIP. Example data includes: Prophylactic antibiotic received within 1 hour prior to surgical incision and Prophylactic antibiotic selection for surgical patients. 4. Display overall information on the perioperative process and progress of the patient through the processing the OR on multiple screens, monitors or displays (OR desk, SPS, Chief of Surgery's office, Surgery suite, PACU, Pre-Op, patient s family waiting room, etc.) and for multiple audiences in order to maintain privacy requirements when/where necessary. 5. Anonymize patient information and align with HIPAA regulations. 6. Provide real time patient tracking via RFID tracking device assigned to patient to be used in conjunction with RTLS designed to eliminate additional keyboard entry. Sensor tags will not interfere with other medical equipment. 7. Provide live real time dashboard designed for OR managers, administration, and surgeons with the information each of the team members need. (browser based) Command center providing continuous patient visibility and communication to physicians, management staff. Anesthesia module to allow anesthesiologist to monitor patient status, flow and associated time stamps across many rooms on one page. Automatic notification alerting surgeons, anesthesiologist, environmental service, SPS when changes made in schedule, patients/room ready. 8. Provide digital patient file display with real time patient information available for all team members to view on dedicated display in the OR with real-time, up-to date patient data for situational awareness. Easy to read display to optimize patient safety and clinical decisions based on real time information. Provide automatic access to key information from diverse IT systems- lab, radiology, medical records, allergies patient safety check list display, information on blood products, lab results, specimen inventory and disposition, staff information. The display maintains visibility of time sensitive information: antibiotic administration, tourniquet time, patient repositioning. Dedicated 55 LED Display LCD TV monitor for each OR with wall mount. (7). PC for message boards (7). 9. Provide IP cameras in each operating suite with controlled access through command center. 10. Provide kiosk for family registration/information. Provide the ability for families to receive updates via personal device. (includes tablet or iPad) 11. Provide surgery scheduling capabilities allowing cases to be scheduled in advance or same day of surgery date. Surgeons entered in system for easy selection. Special equipment such as c-arm, etc. can be loaded into the system for selection when scheduling a case. Ability to select equipment to see and select from drop down list of equipment entered in system. Comment column for other pertinent information. Management of block time by surgeon/specialty. 12. Must be compatible with the current integration provider at the Salisbury location and both HCC locations. c. Reports Requirement. The solution shall: Include a report generator to document: A. Pre-operative events. i. Total time to complete Pre-Op prep/checklist process i. Total length of stay in Pre-Op ii. Order in which the Pre-Op prep/checklist was completed iii. Time to complete each Pre-Op Checklist item iv. Time Patient occupied Pre-Op bed/bay after Pre-Op checklist was completed B. Operating room events. i. Time into OR / Time out of OR ii. Total Anesthesia time (Induction to time out of OR) iii. Operative Time (Incision time to close time) iv. Turnover time v. OR Block Utilization by Surgeon (Percentage of OR time utilized as compared to OR time allocated/blocked for a given surgeon) vi. OR Block Utilization by Service (Ortho, Uro, General, etc...) vii. Time out procedure time (Time safety checklist is started to time safety checklist has been completed) C. Schedule events. i. Total number of ORs anticipated and actually running each day ii. Total number of patients on the surgery waiting list Generate/create ad-hoc user reports. The reports would use the measures listed above but be customizable by the facilities. No additional measures, other than those listed above are required to be included in the ad-hoc reports. Provide automatic reporting and data charts using dashboards with touch of the finger or click of a mouse in real time. d. Interface Requirements. The system provided shall interface with: 1. Veterans Information Systems and Technology Architecture (VistA) Surgery Package - Solution shall supply all VA defined required data elements to VistA Surgery at defined trigger points in the Surgery Scheduling and tracking process; VistA Surgery will continue to supply data to other VistA modules per current processes. A. The system software applications shall be on the One-VA Technical Reference Model (TRM) approved list. B. If the system software application is not on the One-VA TRM approved list, the contractor shall complete One-VA TRM approval not later than 90-days after contract award. 2. VistA Integration Accepts and filters information from VistA to allow views of VistA data elements i.e. labs, ADT. Proposed solution shall have an HL7 interface capable of accepting patient demographic information (ADT) and order (ORM) messages received from the VistA scheduling package. These data elements should be provided in real time and updated automatically. 3. VistA Imaging / Text Integration Utilities (TIU) - Receives images and stores them for display to VistA users. Solution shall supply TIU using existing HL7/VistA Imaging interface and specific note titles. 4. Anesthesia Record Keeping (ARK) Picis, Version 8.6 - Proposed solution shall receive Anesthesia related information from ARK and ARK will receive Surgery Schedule information from the proposed solution. 5. Patient monitors Proposed solution shall receive vital signs related information from the patient monitors located in the operating rooms. VAMC Salisbury currently has the following Philips MP50/ MP70 patient monitor equipment. The 5th floor will have Phillips MX800 monitors. Facility plans to upgrade to the Phillips MX800. d. Server Requirements. The server provided shall: 1. Provide any physical server hardware, OS, and database licenses (such as SQL) required interface to VistA/CPRS. OS shall be a currently supported OS and shall not be prior to Windows Server 2008 (i.e. Windows 2003 is not permitted) 2. Describe whether the system can integrate with Active Directory or LDAP. 3. Provide capability of storing acquired reports for 5 years e. Installation and Configuration Requirements. 1. The Installation shall consist of the following: A. The selected contractor shall conduct site surveys of each of the designated locations within thirty (30) days following contract award. B. Each site survey shall include all electrical and IT cable drops necessary. C. A technical plan for each site shall be submitted with within ten (10) business days after all surveys have been completed. D. Complete installation of each display board workstation: i. Mounting of monitor and associated PC ii. Any necessary Data line pulls iii. Any necessary electrical work required to power monitor and associated PC 2. Configuration shall consist of: A. Interface testing, with the following documentation: i. Kits built for VistA Interfaces ii. Patch descriptions iii. Test scripts iv. Installation guides v. Implementation and back out plans B. Pre-operative events display information configuration requirements: i. Work with the VHA clinical staff to document pre-operative milestones and process flow for each of the milestones. ii. Map VistA/CPRS data elements to pre-operative milestones and document milestone completion criteria. iii. Document criteria for marking a patient ready for transport to Operating Room for planned surgical procedure. iv. Setup alert conditions and appropriate notification mechanism. v. Setup access control for access to Pre-Op milestone completion. vi. Identify locations where read-only Pre-Op dashboard displayed for use by perioperative staff. C. Operating Room events display information configuration requirements: i. Work with the VHA clinical staff to document clinical process flow ii. Verify mapping of VistA/CPRS data elements to display board. iii. Verify mapping of Anesthesia data elements to display board. iv. Configure display board to accept data from physiological monitors v. Configure site-specific checklists. D. Scheduling events display information configuration requirements: i. Work with hospital s perioperative staff to configure site-specific color key ii. Identify locations where read only OR-Schedule dashboard will be displayed for use by perioperative staff iii. Define dashboard configuration for each of the locations. iv. Define access control list for users who can modify the day of surgery schedule v. Define application URL and mechanism to deploy URL for use by authorized users E. Family Waiting display information configuration requirements: i. Work with hospitals perioperative staff to configure ii. Identify locations where display monitor will be located for use by patients loved ones. iii. Define display board workstation configuration for each of the locations. F. Analytics Package configuration requirements: i. Configure predefined reports ii. Configure analytic cube to host data for above reports iii. Define access control list for users who can access these reports iv. Define application deployment method for authorized users f. Training Requirements. 1. Go-live/Initial Training A. Clinical applications training for super-users, administrator, nurses, physicians, and other clinical staff shall be provided onsite during go-live for one week, 8 hour days B. Training shall be provided on the user interface, application, and its features C. Training shall provide super-users and end-users with the capability of being self-sufficient in operating the system by the end of the training session D. On-Site Go-live support for 1 week. 2. Follow-up/Refresher Training - Clinical applications training shall be provided after clinical users have had hands-on experience with the system, between 3-9 months following go-live for at least two days. 3. Provide quick notes or reference guides during on-site training during the Go Live Training. 4. Technical Training to be provided within the first year of installation - Provide technical training for maintenance and service for technical personnel at each site/regional OI&T and/or Biomedical personnel. Training should at minimum address the following topics: A. Commissioning and preventative maintenance B. Troubleshooting C. Server maintenance and backup procedures D. Provide technical training for configuration of each interface E. Provide technical training for configuration of each type of display board workstation F. Provide details as to whether this training will be provided onsite or remotely 4.0 SECURITY. a. Contractor must provide completed documentation for the solution including, but not limited to, VA Directive 6550 and Manufacturer Disclosure Statement for Medical Device Security (MDS2). b. The Contractor shall adhere to all VA Privacy & Security requirements including the Privacy Act and the Business Associate Agreement. c. Any Contractor staff requiring access to the VA network will complete required Privacy training and Rules of Behavior agreements in accordance with VAMC policy d. Must be VA Patient Identification Verification (PIV) compliant 5.0 SERVICE SUPPORT a. During the warranty period, the vendor shall provide service, at no cost, Monday-Friday between the hours of 8:00 am 5:00 pm (excluding federal holidays). b. Vendor will supply 24-hour phone technical support for the duration of ownership of the equipment. c. Vendor must obtain and show proof of National or Point to Point VPN certification. Any offsite server or network maintenance or support provided by the vendor can only be done via VPN access. d. Offer a service support agreement with base year plus three additional years. This shall include all interfaces, remote service or application access charges, telephone technical or application support charges, or any fees associated with supporting this equipment. e. Provide coverage under the same install team locally once the implementation is complete. ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 SURGICAL WORKFLOW SOLUTION Software License Meeting all SOW requirements 7.00 EA __________________ __________________ 0002 SURGICAL WORKFLOW SOLUTION SAFE Application Implementation Meeting all SOW requirements 1.00 EA __________________ __________________ 0003 SURGICAL WORKFLOW SOLUTION - 55" Samsung Sync Master MD55B LED Display LCD TV 1080p (Full HD) Message Board Meeting all SOW requirements 7.00 EA __________________ __________________ 0004 SURGICAL WORKFLOW SOLUTION Monitor Wall Mount with CPU Holder Meeting all SOW requirements 7.00 EA __________________ __________________ 0005 SURGICAL WORKFLOW SOLUTION Dell Small Form Factor PC for Message Boards Meeting all SOW requirements 7.00 EA __________________ __________________ 0006 SURGICAL WORKFLOW SOLUTION - Annual SAFE Software Code Maintenance and Support Maintenance Meeting all SOW requirements 1.00 EA __________________ __________________ 0007 SURGICAL WORKFLOW SOLUTION Annual SAFE Software Code Maintenance and Support Maintenance Meeting all SOW requirements 21.00 EA __________________ __________________ 0008 SURGICAL WORKFLOW SOLUTION Software License - Meeting all SOW requirements 15.00 EA __________________ __________________ 0009 SURGICAL WORKFLOW SOLUTION Command Center Software License Software for Dashboard Analytics real-time reporting and updates. Meeting all SOW requirements 1.00 EA __________________ __________________ 0010 SURGICAL WORKFLOW SOLUTION - Creation, Installation, Testing, and Verification of HL7 Interfaces for Real View Software Meeting all SOW requirements 1.00 EA __________________ __________________ 0011 SURGICAL WORKFLOW SOLUTION Software Install, Setup, Go-live: RTLS Selection and Placement, and Workflow/ Timestamp Definition Installation Activities include, but are not limited to: Kickoff and assessment meeting, Meeting all SOW requirements 1.00 EA __________________ __________________ 0012 SURGICAL WORKFLOW SOLUTION Training Includes Super-User, Administrator and End-User Sessions Training (Three Training Sessions) Super User Training - 2 days Administrator Training - ? day User Training - 1 hour: Meeting all SOW requirements 3.00 EA __________________ __________________ 0013 SURGICAL WORKFLOW SOLUTION - RTLS Software Engine License Meeting all SOW requirements 1.00 EA __________________ __________________ 0014 SURGICAL WORKFLOW SOLUTION - Wireless Patient Care Tag S-Tag G2 Meeting all SOW requirements 50.00 EA __________________ __________________ 0015 SURGICAL WORKFLOW SOLUTION HDR Wireless Gateway Receiver (REC-A150) Meeting all SOW requirements 55.00 EA __________________ __________________ 0016 SURGICAL WORKFLOW SOLUTION PLANNING COMMISSIONING AND SITE ACCEPTANCE TESTING Meeting all SOW requirements 1.00 EA __________________ __________________ 0017 SURGICAL WORKFLOW SOLUTION - Media Server License for IP Cameras Meeting all SOW requirements 1.00 EA __________________ __________________ 0018 SURGICAL WORKFLOW SOLUTION Family Kiosk Stand (includes a windows tablet or an iPad) Meeting all SOW requirements 1.00 EA __________________ __________________ 0019 SURGICAL WORKFLOW SOLUTION 55" Samsung Sync Master MD55B LED Display LCD TV 1080p (Full HD) Message Board Meeting all SOW requirements 11.00 EA __________________ __________________ 0020 SURGICAL WORKFLOW SOLUTION Dell Small Form Factor PC for Message Boards Meeting all SOW requirements 9.00 EA __________________ __________________ 0021 SURGICAL WORKFLOW SOLUTION Ergotron Neo-Flex Wall Mount Display Bracket (37-63") Meeting all SOW requirements 9.00 EA __________________ __________________ 0022 SURGICAL WORKFLOW SOLUTION Dell Rack Mountable Application Server Meeting ALL SOW requirements 1.00 EA __________________ __________________ 0023 SURGICAL WORKFLOW SOLUTION IP Camera for each OR Meeting all SOW requirements 7.00 EA __________________ __________________ 0024 SURGICAL WORKFLOW SOLUTION 7.00 EA __________________ __________________ 0025 SURGICAL WORKFLOW SOLUTION Software Code Maintenance Meeting all SOW requirements 21.00 EA __________________ __________________ 0026 SURGICAL WORKFLOW SOLUTION QUANTITY DISCOUNT FOR ITEMS LISTED DISCOUNT - QTY 1.00 EA __________________ __________________ 0027 SHIPPING TO DESTINATION - Salisbury, NC 28144 LOCAL STOCK NUMBER: FREIGHT 1.00 EA __________________ __________________ GRAND TOTAL __________________
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/VA24617Q0806/listing.html)
 
Document(s)
Attachment
 
File Name: VA246-17-Q-0806 VA246-17-Q-0806_5.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3560459&FileName=VA246-17-Q-0806-005.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3560459&FileName=VA246-17-Q-0806-005.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04535749-W 20170609/170607234836-8a244d8565af118c6be3cc68d9b26806 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.