DOCUMENT
65 -- Steam sterilizers/washer dis-infectors -building layout - Attachment
- Notice Date
- 9/5/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
- ZIP Code
- 85014
- Solicitation Number
- VA25817Q0739
- Response Due
- 9/15/2017
- Archive Date
- 9/30/2017
- Point of Contact
- shawnta butler ignacio
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- RAYMOND G. MURPHY VA MEDICAL CENTER STEAM STERILIZERS AND WASHER DIS-INFECTORS STATEMENT OF WORK (SOW) as of 05/01/17 Contracting Officer s Representative (COR). Name: Joseph Mendoza Section: SPS/Logistics Address: 1501 San Pedro SE Albuquerque, NM 87108 Phone Number: 505-256-5414 Fax Number: 505-256-6420 E-Mail Address: Joseph.mendoza@va.gov Contract Title. Raymond G. Murphy VA Medical Center (Albuquerque, NM) Request four Steam Sterilizer & Washer/Disinfectors units for the Sterile Processing Service. Background. The procurement of four Steam Sterilizer & four Washer/Disinfectors units for the Sterile Processing Service.is necessary as the existing equipment 1) has reached end of life and 2) additional processing capacity is required to meet the current and future demand of the Surgery Department. Scope. The overall scope of work is the procurement of four Steam Sterilizers & four Washer/Disinfectors units for the SPS Department. The selected equipment manufacturer will furnish all necessary equipment as specified in the Project Construction Documents. This will also include installation of four Steam Sterilizers & four Washer/Disinfectors units. These units and services will be provided for the Raymond G. Murphy VA Medical Center. Specific Tasks. Tasks to be completed by the equipment supplier include: Provide Project Management Services responsible for planning and project coordination with the facility and/or general contractor. Coordinate equipment manufacturing and delivery according to the construction schedule and project timelines. Inspect all site preparation work to assure all utility connections and wall opening are the correct size and according the installation drawings. Schedule installation engineers to be onsite and inspect equipment for damage while still on the truck. Transport equipment from loading dock to established staging and assembly area. This area can be determined by the GC and/or facility. Assembly and set-up of all equipment. Place all units in final location and install seismic anchors. Install stainless steel trim kits and upper enclosures above equipment. With the GC and corresponding sub-contractors present, make final utility connections. Equipment start-up and programming according to SPS Department s specific processing needs. Perform cycle testing on equipment. Provide sterilizer cycle verification. Conduct all necessary in-service and training as requested by the clinical users. Warranty will commence with the first clinical use of the equipment and upon user s permission. Steam Sterilizers must have: (QTY 4) Sterilizer chamber shall be rectangular and be encapsulated in sheet metal. This is to minimize the BTU load on the existing department air handlers. Heat rejection per sterilizer shall not exceed 1.8kW. All required service access for the sterilizer shall be accessible through the front of the units only (no side or rear service access requirements). This is to allow for the sterilizers to be placed side by side in the existing space without architectural layout modifications. Sterilizer chamber doors cannot be hinged and shall be a one piece, powered, vertical slide type. Sterilizer external dimensions cannot exceed 39 in width and have a (12) container capacity. This is dimension is required to fit (4) in the existing space. All wetted surfaces (plumbing and valving included) shall be constructed of high-grade stainless steel and have the ability to support steam created from purified (RO or DI) water. Total dry time shall be automatically varied and adjusted on each cycle by the sterilizer based on load size. Door seal gasket shall be actuated using pressurized air (pneumatic). This allows for the door gaskets to be replaced by SPS staff in less than 10 minutes, minimizing equipment downtime. Instrument Washer/Disinfectors must have: (QTY4 ) Water usage, per load, is automatically varied by the washer in response to the size of the load. External unit dimensions (cannot exceed) of 36 in width. This is required to fit the new washer solution, including the washer rack return, in the existing space without architectural layout modifications or requiring a new pass through window. A thermal disinfection A0 level of at least 3000 and shown on the user interface display at the end of the disinfection rinse cycle; to maximize safe instrument handling by the SPS staff. Washer control system which actively monitor and record each wash step to assure every parameter is met on every cycle. Utilize a direct exhaust connection with a pressure not to exceed 250 CFM. Dry temperature must achieve a minimum of 130C. 5.1 Task 1 - Enterprise Management Controls. 5.1.1 Subtask 1 - Integration Management Control Planning. The Selected Manufacturer will conduct an audit and deliver a field report on the site preparation requirements establish in the installation drawings. This will be performed at the completion of rough MEPs and before final delivery is scheduled. This report is to be completed by equipment manufacturer s Project Management team. Deliverables: Field Site Preparation Audit and Report Performance Monitoring Security Requirements The C&A requirements do not apply, and that a Security Accreditation Package is not required: Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). N/A Other Pertinent Information or Special Considerations. The equipment specified for the SPS Relocation project is highly specialized. Only manufacturer s authorized installation technicians shall perform installation duties. Identification of Possible Follow-on Work. The new equipment shall carry a (1) year parts and labor warranty. Continued training and in- servicing will be available at no cost for the life of the equipment if deemed necessary by SPS Department heads. Identification of Potential Conflicts of Interest (COI). N/A Identification of Non-Disclosure Requirements. N/A Packaging, Packing and Shipping Instructions. N/A Inspection and Acceptance Criteria. The COR is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services. A demo period or trial is not inspection of a product. Risk Control All infection control and dust containment barriers will be provided by the GC. The equipment manufacturer will comply with all facility infection control policies and protocols. Place of Performance. All work will be performed within the relocated SPS Department located on the basement level of the Raymond G. Murphy VA Medical Center. Period of Performance. Start date and completion have yet to be determined by the GC. Equipment need by date is approximately Q4 2017. Delivery Schedule. To be determined Washer will be in BC-110 going into BC-111 Sterilizers are in BC-110A facing into BC-111 X X X X
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25817Q0739/listing.html)
- Document(s)
- Attachment
- File Name: VA258-17-Q-0739 VA258-17-Q-0739_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3777133&FileName=VA258-17-Q-0739-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3777133&FileName=VA258-17-Q-0739-001.docx
- File Name: VA258-17-Q-0739 SOW-Steam Sterilizers_washer Dis-infector _Qty 4_.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3777134&FileName=VA258-17-Q-0739-002.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3777134&FileName=VA258-17-Q-0739-002.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA258-17-Q-0739 VA258-17-Q-0739_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3777133&FileName=VA258-17-Q-0739-001.docx)
- Record
- SN04661201-W 20170907/170905231604-713e803a0c5ff2424b2330a0738dbfb4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |