Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 14, 2017 FBO #5804
SOLICITATION NOTICE

20 -- A/C COMPRESSOR REPAIR FOR CGC CAPSTAN - FAR CLAUSES - SCOPE OF WORK

Notice Date
10/12/2017
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States
 
ZIP Code
21226-5000
 
Solicitation Number
70Z085-18-Q-P45140
 
Archive Date
11/2/2017
 
Point of Contact
Mayra C. Centurion, Phone: 5106375987
 
E-Mail Address
mayra.c.centurion@uscg.mil
(mayra.c.centurion@uscg.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Scope of Work FAR CLAUSES U.S COAST GUARD is soliciting the following: WORK ITEM 1: A/C System Repairs 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to repairs to the A/C piping onboard 1.2 Government-furnished property. None. 2. REFERENCES COAST GUARD DRAWINGS Coast Guard Drawing 65-WYT_3801_3 HL-PRESS A/C SYS COMPONENTS COAST GUARD PUBLICATIONS Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2014, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), Jan 2014, Welding and Allied Processes 3. REQUIREMENTS 3.1 General. The Contractor shall conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this work item. 3.1.1 CIR. None. 3.1.2 Tech Rep. Not Applicable 3.1.3 Protective measures - general. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces in the vicinity of the work area against contamination during the performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination. 3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). 3.1.5 Welding and allied procedures shall be in accordance with SFLC Std Spec 0740 3.1.7 Security access. Check-in with watch stander and be issued a visitor badge. 3.2 Remove and Install 3.2.1 Contractor shall evacuate the refrigerant (R-22) from the system. 3.2.2 Contractor shall procure and install ¾" vibration eliminating hose and A/C service valve. Coast Guard personnel will install hose and valve. Contractor will supply brazing/soldering supplies. 3.2.3In the presence of the Coast Guard Inspector, after completing repairs, the contractor shall place the system under a vacuum and verify zero leakage. 3.2.4 Contractor shall procure 10.5 lbs of R-22 and fill system. 3.3 Operational Test. In the presence of the Coast Guard Inspector, after completing all authorized repairs, Coast Guard personnel will test run the system 4. NOTES This section is not applicable to this work item. POP: Will be determine upon Cutter's and Tech availability. * Please provide active DUNS number with quote. References and drawings will be available upon request.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGELC/70Z085-18-Q-P45140/listing.html)
 
Place of Performance
Address: CGC CAPSTAN, 1 WASHINGTON AVE, PHILADELPHIA, Pennsylvania, 19147, United States
Zip Code: 19147
 
Record
SN04711818-W 20171014/171012230907-cb57e52a9171d58b74b788eef0e602f0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.