DOCUMENT
59 -- Electrical Breaker Panel - Attachment
- Notice Date
- 10/19/2017
- Notice Type
- Attachment
- NAICS
- 335313
— Switchgear and Switchboard Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
- ZIP Code
- 23667
- Solicitation Number
- 36C24618Q0059
- Response Due
- 10/24/2017
- Archive Date
- 11/3/2017
- Point of Contact
- Jeremy Boston
- Small Business Set-Aside
- N/A
- Description
- This is a Sources Sought Notice for a Breaker Panel without installation for the Richmond VAMC. Please respond if you have the ability and intent to complete this requirement. Include in your response a copy of your capabilities statement and FSS or GSA Contract Number, if applicable. This Sources Sought Notice is intended to locate Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), and Small Businesses. The anticipated NAICS Code for this requirement is 335313. This is not a Request for Quotation and quotes shall not be reviewed at this time. The Department of Veterans Affairs shall not be responsible for any costs incurred by the contractor as a result of this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. All responses shall be submitted via email by Tuesday, October 24, 2017 at 10:00 AM EST. Responses shall be submitted to Jeremy Boston at Jeremy.Boston@va.gov. Phone calls shall not be accepted for this notice. Salient Characteristics to meet the minimum needs of the Government are as follows: Panel Can Shall be 72" TALL X 42" WIDE X 13" DEEP (No deviation will be accepted as it is replacing a current box) 1 I-Line MB Panel (Interior) I-Line Panel Board consisting of 208/120V, 3PH 4W, 60HZ SCCR 24 KA Fully Rated, Suitable for use as Service Entrance UL Single Main: 800 AMP, 3 pole MG Circuit Breaker Incoming Conductors (3) 3/0- 500KCMIL Copper Ground Bar, Buss Copper/ Tin Plated Type 1 Incoming Bottom Trim, Four Piece surface Door in door hinge covers Breakers shall rated at 24 KV or above: 1 - 70A/2P FA 1 - 20A/3P FA PREPARED SPACE 1 - 70A/3P FA 1 - 100A/3P FA 1 - 125A/3P QB 3 - 150A/3P QB 1 - 200A/3P QB 1 - 225A/3P QB Solid Neutral Standard Ground Bar Standard Mains and Feeders Mechanically Restrained Special: Fit Exiting Box
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/36C24618Q0059/listing.html)
- Document(s)
- Attachment
- File Name: 36C24618Q0059 36C24618Q0059.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3861234&FileName=36C24618Q0059-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3861234&FileName=36C24618Q0059-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C24618Q0059 36C24618Q0059.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3861234&FileName=36C24618Q0059-000.docx)
- Record
- SN04717546-W 20171021/171019230831-04bb211891ac5de7954cbc9e8030f5a1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |