Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 10, 2017 FBO #5861
DOCUMENT

46 -- Monochloramine System and Equipment - Attachment

Notice Date
12/8/2017
 
Notice Type
Attachment
 
NAICS
#221310 — Water Supply and Irrigation Systems
 
Contracting Office
Department of Veterans Affairs;Cincinnati VA Medical Center;260 E. University Avenue, 2nd Floor;Cincinnati, Ohio 45219-2356
 
ZIP Code
45219-2356
 
Solicitation Number
36C25018Q9000
 
Response Due
12/22/2017
 
Archive Date
3/22/2018
 
Point of Contact
Ron Heidemann
 
Small Business Set-Aside
N/A
 
Description
This is not a solicitation announcement. This is a Sources Sought publication only. The purpose of this Sources Sought notice is solely for information and planning purposes and does not constitute a solicitation. Please do not submit a proposal in response to this notice. This notice is to assist the VA in the determination of sources only. A solicitation is not currently available. Responses to this Sources Sought Notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Cincinnati Veterans Affairs Medical Center is planning a project to correct system water leaks throughout the hospital, correct infection control issues and improving water efficiency of all water using and/or plumbing devices in the main hospital building (#1) at the Cincinnati VAMC. This project will install a manufacturer approved, NSF (National Sanitation Foundation)/ANSI (American National Standards Institute) 61 certified secondary water treatment system which shall consist of the following components: (1) Monochloramine generator capable of 800 grams per hour maximum production to serve domestic cold water system. (1) Monochloramine generator capable of 150 grams per hour maximum production to serve domestic hot water system. (2) 165 gallon, double wall, polyethylene storage tanks with threaded lid, and integral pump shelf. Hot tap magmeter flow sensors with operating range 0.05 to 10 m/s (0.15 to 33 ft/s). ANSI/AWWA (American Water Works Association) Standard C701 certified compound-type water meters with electronic register including: fully programmable pulse output frequency, integral data logging capability, integral resettable accuracy testing feature, large, easy-to-read LCD display, and 10-year battery life. NSF/ANSI 61 certified reagents to generate monochloramine. (20) Monitoring panel and data log capable of direct sensor measurements of pH, oxidant residual potential, conductivity, pressure, temperature, and capable of integrating with the building s energy management system. Additionally, this project will study and address dead legs and scald gard protection and continuous monitoring throughout both facilities. The Department of Veterans Affairs (VA), Cincinnati VA Medical Center, Cincinnati, OH is seeking manufactures of a monochloramine system at 3200 Vine Street, Cincinnati, Ohio 45220. If you are interested and are capable of providing the required monochloramine system please provide the requested contact information. Responses to this notice should include a company name, address, point of contact (Name, Phone Number and e-Mail Address) and a capability statement. The capability statement should include: Technical capabilities Full description of the system Information on past installation(s) in the last 5 years (VA Medical Centers would be helpful) the manufacture of system and NSF-certification. Please limit your response to this synopsis to five pages (if possible). Direct all responses via email to Ron Heidemann, Contracting Officer, at Ronald.Heidemann@va.gov by December 22, 2017 4:00PM EST.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/36C25018Q9000/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25018Q9000 36C25018Q9000.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3954891&FileName=36C25018Q9000-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3954891&FileName=36C25018Q9000-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 3200 Vine Street;Cincinnati, Ohio 45220
Zip Code: 45220
 
Record
SN04761470-W 20171210/171208230823-d4bc8e54dbd95a552e4fc0d3c4e60e46 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.