DOCUMENT
46 -- Monochloramine System and Equipment - Attachment
- Notice Date
- 12/8/2017
- Notice Type
- Attachment
- NAICS
- #221310
— Water Supply and Irrigation Systems
- Contracting Office
- Department of Veterans Affairs;Cincinnati VA Medical Center;260 E. University Avenue, 2nd Floor;Cincinnati, Ohio 45219-2356
- ZIP Code
- 45219-2356
- Solicitation Number
- 36C25018Q9000
- Response Due
- 12/22/2017
- Archive Date
- 3/22/2018
- Point of Contact
- Ron Heidemann
- Small Business Set-Aside
- N/A
- Description
- This is not a solicitation announcement. This is a Sources Sought publication only. The purpose of this Sources Sought notice is solely for information and planning purposes and does not constitute a solicitation. Please do not submit a proposal in response to this notice. This notice is to assist the VA in the determination of sources only. A solicitation is not currently available. Responses to this Sources Sought Notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Cincinnati Veterans Affairs Medical Center is planning a project to correct system water leaks throughout the hospital, correct infection control issues and improving water efficiency of all water using and/or plumbing devices in the main hospital building (#1) at the Cincinnati VAMC. This project will install a manufacturer approved, NSF (National Sanitation Foundation)/ANSI (American National Standards Institute) 61 certified secondary water treatment system which shall consist of the following components: (1) Monochloramine generator capable of 800 grams per hour maximum production to serve domestic cold water system. (1) Monochloramine generator capable of 150 grams per hour maximum production to serve domestic hot water system. (2) 165 gallon, double wall, polyethylene storage tanks with threaded lid, and integral pump shelf. Hot tap magmeter flow sensors with operating range 0.05 to 10 m/s (0.15 to 33 ft/s). ANSI/AWWA (American Water Works Association) Standard C701 certified compound-type water meters with electronic register including: fully programmable pulse output frequency, integral data logging capability, integral resettable accuracy testing feature, large, easy-to-read LCD display, and 10-year battery life. NSF/ANSI 61 certified reagents to generate monochloramine. (20) Monitoring panel and data log capable of direct sensor measurements of pH, oxidant residual potential, conductivity, pressure, temperature, and capable of integrating with the building s energy management system. Additionally, this project will study and address dead legs and scald gard protection and continuous monitoring throughout both facilities. The Department of Veterans Affairs (VA), Cincinnati VA Medical Center, Cincinnati, OH is seeking manufactures of a monochloramine system at 3200 Vine Street, Cincinnati, Ohio 45220. If you are interested and are capable of providing the required monochloramine system please provide the requested contact information. Responses to this notice should include a company name, address, point of contact (Name, Phone Number and e-Mail Address) and a capability statement. The capability statement should include: Technical capabilities Full description of the system Information on past installation(s) in the last 5 years (VA Medical Centers would be helpful) the manufacture of system and NSF-certification. Please limit your response to this synopsis to five pages (if possible). Direct all responses via email to Ron Heidemann, Contracting Officer, at Ronald.Heidemann@va.gov by December 22, 2017 4:00PM EST.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/36C25018Q9000/listing.html)
- Document(s)
- Attachment
- File Name: 36C25018Q9000 36C25018Q9000.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3954891&FileName=36C25018Q9000-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3954891&FileName=36C25018Q9000-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25018Q9000 36C25018Q9000.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3954891&FileName=36C25018Q9000-001.docx)
- Place of Performance
- Address: 3200 Vine Street;Cincinnati, Ohio 45220
- Zip Code: 45220
- Zip Code: 45220
- Record
- SN04761470-W 20171210/171208230823-d4bc8e54dbd95a552e4fc0d3c4e60e46 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |