DOCUMENT
65 -- ERBE-ARGON PLASMA COAGULATOR - Attachment
- Notice Date
- 1/23/2018
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 4;Acquisition (90C;1010 Delafield Road;Pittsburgh, PA 15215
- ZIP Code
- 15215
- Solicitation Number
- 36C24418Q9114
- Response Due
- 1/29/2018
- Archive Date
- 2/28/2018
- Point of Contact
- donna.cooper2@va.gov
- E-Mail Address
-
Donna.Cooper2@va.gov
(Donna.Cooper2@va.gov)
- Small Business Set-Aside
- N/A
- Description
- Purpose and Objectives: The intent of this Sources Sought Notice is to identify in locating capable small businesses, including Service Disabled and Veteran Owned small businesses, or any business size, capable of providing the items as listed in the attached Statement of Need. NAICS Code 339112, Surgical and Medical Instrument Manufacturing. These items are for the Department of Veteran Affairs, Corporal Michael J Crenscenz VAMC Philadelphia, PA 19104. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the attached document. Responses should include the following information: Business name, address, Point of Contact, business size info. All information is to be submitted via e-mail at donna.cooper2@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 2:00pm EST on Monday, January 29, 2018. No submissions will be accepted after this date and time. Questions can be submitted electronically to donna.cooper2@va.gov. This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. See attached document: DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document Electrosurgical Equipment Salient Characteristics: VIO 300D Electrosurgical Unit - Constant Voltage Platform with Automated Power Regulation with adjustment option. Cut Mode: Must have a Dry Cut and Bipolar cutting mode for usage in Transurethral Resection of the Prostate. The cut mode alternates between cut and coag, automatically adjusting wattage based on the patient s needs and has the ability to control the intensity of coagulation, length of each cut and time in between each cut. Coagulation Mode: Soft Coagulation with optional auto stop Must have Power Peak System (PPS). ReMode Functionality (Ability to change power settings with foot pedal) Must have NESSY (Neutral Electrode Safety System). Capability to accommodate vessel sealing instruments for usage in open and laparoscopic surgery. Compatible with ERBE VIO Equipment. Compatible with BIPOLAR RESECTION Adapter: adapter designed for use with a vaporization electrode. Compatible with Richard Wolf Equipment. APC2 Argon Plasma Coagulator - Must have Precise APC Mode Argon Plasma Coagulation mode that automatically adjusts the intensity of the beam in real time based on how close you are to the tissue. Must have Auto Purge ability Choice of Probe Socket (utilizes plug and play technology with integrated filter) or OR socket (for use with operating room handles) Disposable Argon Probe must have a built in filter. Must be Circumferential Probe Compatible. Manufacturer Specifications - APC 300, Erbe MODEL APC 300 OUTPUT POWER W @ flow rate: 2-5.5 l/min (OUTPUT POWER) Depends on ESU 6-10 l/min (OUTPUT POWER) Depends on ESU W @ flow rate: 4-8 l/min (OUTPUT POWER) Depends on ESU 4-10 l/min (OUTPUT POWER) Depends on ESU MARKETED SINCE (GRAPHICS DISPLAY) 1996 FORMAT (WAVELENGTH, nm) Module used with ESU ALERTS (CONFIGURATION) Audio volume, db (ALERTS) 65 at 1 meter OPERATING CONDITIONS TEMPERATURE RANGE, Â °C (STIRRER) 10 to 40 Humidity range, % (OPERATING CONDITIONS) 30 to 75 Warranty (PURCHASE INFORMATION) 1 year CONSOLE Dimensions (hxwxd),cm (in) (ANTECHAMBER) 10.5 x 41 x 38 (4.1 x 16.1 x 15) WEIGHT, kg (lb) (DISPLAY) 7 (15.4) without gas cylinder POWER NEEDED, VAC (ENERGY) 90-240, 50/60 Hz Current, a 0.3 STORAGE CONDITIONS TEMPERATURE RANGE, Â °C (STIRRER) -20 to +70 Humidity range, % (OPERATING CONDITIONS) 0 to 95 ARGON GAS SYSTEM Flow range, l/min (ARGON GAS SYSTEM) 0.1 Filter pore size (ARGON GAS SYSTEM) 0.2 um external Max. volume tank, l (cu ft) (ARGON GAS SYSTEM) 1,200 (42) Low-pressure alarm (ARGON GAS SYSTEM) Yes OTHER ATTRIBUTES (Interference compensation) Low-constant-flow system; automatic flow adjustment; 10 programmable flow and purge setups; automatic instrument recognition; rigid and flexible endoscopy; self-tests; error messages. 1 FDA CLEARANCE (Interference compensation) Yes Meets requirements of BSI, CSA, EN 46001, IEC, ISO 9000, SEV, TUV, and UL. CE MARK (MDD) (Interference compensation) Yes MARKETING REGION (Interference compensation)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24418Q9114/listing.html)
- Document(s)
- Attachment
- File Name: 36C24418Q9114 36C24418Q9114_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4035763&FileName=36C24418Q9114-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4035763&FileName=36C24418Q9114-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C24418Q9114 36C24418Q9114_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4035763&FileName=36C24418Q9114-000.docx)
- Place of Performance
- Address: Department of Veteran Affairs;Corporal Michael J Crenscenz VAMC;Medical Service / GI Lab;3900 Woodland Avenue;Philadelphia, PA
- Zip Code: 19104
- Zip Code: 19104
- Record
- SN04797037-W 20180125/180123231315-31862826906b925966c6646ba2433542 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |