Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 27, 2018 FBO #5909
DOCUMENT

65 -- Amendment to RFI for Combined Orthotic/Prosthetic - Attachment

Notice Date
1/25/2018
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Commodities & Services Acquisition Svc;(003B6E);555 Corporate Circle;Golden CO 80401-5621
 
ZIP Code
80401-5621
 
Solicitation Number
36C79118Q9202
 
Archive Date
2/24/2018
 
Point of Contact
Jenna Pfenninger
 
Small Business Set-Aside
N/A
 
Description
The purpose of this amendment is to clarify that Samples will not be required in response to the RFI FBO#36C79118Q9202/Orthotic Softgoods and Prosthetic Socks. This amendment hereby changes the language to the following documents: 1. Non-Pneumatic Walking Splint (L4386); 2. Pneumatic Walking Splint (L4360). The following documents are hereby changed from: DRAFT MINIMUM TECHNICAL REQUIREMENTS Non-PNEUMATIC WALKING SPLINT (L4386) Cam-walker type; non-hinged boot Indications: Alternative to casting for fracture of the mid-tibia or fibula to mid-foot area Second and third degree ankle sprains. Minimum Technical Requirements: Item must have all of the below features and sizes. Design: Cam-Walker, non-hinged, non-pneumatic type Size Range: M L XL OR EQUIVALENT SIZES Length: Full foot length Closure: Hook & Loop Closure - calf, instep and forefoot straps Material: Open celled foam or equivalent (no latex) Must be removable and replaceable Must have replacement liners available Height- Both Small and Tall versions are required Short Tall Offerors must include literature and samples for both short and tall versions Uprights: Non-hinged Rocker bottom non-skid sole Extra pads to adjust fit Universal must fit both Right and Left sides PNEUMATIC WALKING SPLINT (L4360) Cam walker type; non-hinged Indications: Foot/Ankle protection Stable fracture of foot/ankle Severe ankle sprain (grade III) Post-op immobilization Minimum Technical Requirements: Item must have all of the below features, and sizes. Design: Cam Walker, non-hinged, pneumatic type Size: M L XL OR EQUIVALENT SIZES Length: Full foot length Closure: Hook and loop with circumferential closure straps Material: Open cell foam or equivalent(no latex), must be removable, and replaceable (must have replacement liners available) Height- Both Small and Tall versions are required Short Tall Offerors must include literature and samples for both short and tall versions Uprights: Non-hinged Rocker bottom non-skid sole Extra pads to adjust fit Pneumatic Universal - must fit both Right and left sides TO: DRAFT MINIMUM TECHNICAL REQUIREMENTS Non-PNEUMATIC WALKING SPLINT (L4386) Cam-walker type; non-hinged boot Indications: Alternative to casting for fracture of the mid-tibia or fibula to mid-foot area Second and third degree ankle sprains. Minimum Technical Requirements: Item must have all of the below features and sizes. Design: Cam-Walker, non-hinged, non-pneumatic type Size Range: M L XL OR EQUIVALENT SIZES Length: Full foot length Closure: Hook & Loop Closure - calf, instep and forefoot straps Material: Open celled foam or equivalent (no latex) Must be removable and replaceable Must have replacement liners available Height- Both Small and Tall versions are required Short Tall Offerors must include literature for both short and tall versions Uprights: Non-hinged Rocker bottom non-skid sole Extra pads to adjust fit Universal must fit both Right and Left sides PNEUMATIC WALKING SPLINT (L4360) Cam walker type; non-hinged Indications: Foot/Ankle protection Stable fracture of foot/ankle Severe ankle sprain (grade III) Post-op immobilization Minimum Technical Requirements: Item must have all of the below features, and sizes. Design: Cam Walker, non-hinged, pneumatic type Size: M L XL OR EQUIVALENT SIZES Length: Full foot length Closure: Hook and loop with circumferential closure straps Material: Open cell foam or equivalent(no latex), must be removable, and replaceable (must have replacement liners available) Height- Both Small and Tall versions are required Short Tall Offerors must include literature for both short and tall versions Uprights: Non-hinged Rocker bottom non-skid sole Extra pads to adjust fit Pneumatic Universal - must fit both Right and left sides Nothing follows.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VADDC791/VADDC791/36C79118Q9202/listing.html)
 
Document(s)
Attachment
 
File Name: 36C79118Q9202 36C79118Q9202_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4042253&FileName=36C79118Q9202-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4042253&FileName=36C79118Q9202-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04799500-W 20180127/180125231122-1cfd6a9be4599dda636e5f3a197893e8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |