Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 11, 2018 FBO #5952
DOCUMENT

65 -- Biological Agent Compounding Hood - Attachment

Notice Date
3/9/2018
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
 
ZIP Code
23667
 
Solicitation Number
36C24618Q0536
 
Response Due
3/15/2018
 
Archive Date
3/16/2018
 
Point of Contact
Desiree Mills
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited. The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified vendors who can provide the exact match for the following no later than 30 days after receipt of the order: 1 EACH: Class II Type A2 biological safety cabinet which ensures safety and containment of biological agents during compounding procedures. -The manufacturer should offer a 6-year warranty on the cabinet. -Must provide delivery within 30 after receipt of the order (ARO). -The cabinet should have the following exact specifications and physical characteristics: Size- 4' Opening Max.- 20" Electrical (Requires 20-AMP Outlet) 115V, AC 20A, 60 Hz Interior Dimension Usable Workspace (w x d) 44" x 203 16 Interior Dimension (w x d x h) 46" x 249 16" x 277 16" Exterior Dimensions (w x d x h) 533 4" x 309 16" x 613 4" Cabinet Weight* (lbs.) 668 Shipping Weight** (lbs.) 798 Sash Height 8" / 10" / 12" Noise (dBa) 60 / 61 Operating Amperage Typical (Amps) 3.6 / 4.0 / 4.3 Operating Amperage ReadySAFE mode (Amps) 1.6 / 1.7 / 1.8 Power Consumption Typical (Watts) 414 / 460 / 495 Power Consumption readySAFE mode (Watts) 184 / 196 / 207 Heat Generation Typical (BTU/hr.) 628/669/706 Heat Generation Ready SAFE (BTU/hr.) 628 / 669 / 706 Essential Physical Characteristics: One-piece, corrosion-resistant, stainless steel fabrication with smooth radius coved corners Negative pressure double-wall plenum NSF-listed and patent pending cable port on the right side Right side Petcock Valve - VAC Internal GFCI protected duplex outlets located on each sidewall Right side pre-piped penetration Power/processor fault alarm to alert of a power outage or micro-controller fault Unique momentum air curtain for increased containment and protective capabilities High velocity return air slots Patent pending air bypass padded armrest Non-glare, removable work surface Mini analog pressure gauge Energy saving features ReadySAFE (tm) low-flow mode StediFLOW (tm) motor controller UniPressure (tm) Preflow Plenum airflow system Flex AIR Canopy Exhaust Connection, 12"O.D. Airtight Damper 12in O.D. Channel Stand All responses shall be submitted no later than 12:00 Noon eastern standard time 3/15/18. All interested parties should respond, in writing via email to desiree.mills-hicks@va.gov No telephone inquiries will be accepted. In response, please include the following: Company/individual name Address Point of contact with phone number Indicate FSS/GSA contract number or Open Market, if applicable Tax ID number DUNS number Capabilities Statement Company Socio-Economic SIZE (example large, small, SDVOSB, VOSB, WOSB etc.) Proof of verification as a SDVOSB/VOSB (if applicable) If your firm/company is a SDVOSB or VOSB, the firm/company must be VERIFIED in the VIP database (see internet site: http://vip.vetbiz.gov) as prescribed under the Veterans First Contracting Program as implemented in VAAR subpart 819.70. The Veteran Administration is mandated by Public Law 109-461 (38 USC § 8127 & 8128) to give first priority to SDVOSB and VOSB concerns if there should be sufficient firms available to compete under a set aside. If insufficient veteran owned small business responses are received to establish the basis for setting this action aside for other than large business participation, then the action will be advertised as a small business set aside or full and open competition. In this case, all interested parties responding shall be eligible to bid. The NAICS 339113- Surgical Appliance and Supplies Manufacturing is applicable to this acquisition; with a size standard of 750 Employees. Interested firms are reminded that in accordance with FAR 4.1201(a) Prospective contractors shall complete electronic annual representations and certifications at the System for Award Management (SAM) as a part of required registration in conjunction with FAR 4.1102(a) that states, Prospective contractors shall be registered in the (SAM) database prior to award of a contract or agreement. Therefore, due to time constraints, vendors must be registered in System for Award Management (SAM) at http://www.sam.gov to be considered for an award.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/36C24618Q0536/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24618Q0536 36C24618Q0536.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4139272&FileName=36C24618Q0536-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4139272&FileName=36C24618Q0536-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04849882-W 20180311/180309231343-f7c5042fdba6a9595a946aaf376bbace (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.