66 -- Stepper Motor System for Pandora Instrument - 80NSSC18Q0390

Notice Date
3/13/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335312 — Motor and Generator Manufacturing
 
Contracting Office
NASA Shared Services Center (NSSC), Building 1111, Jerry Hlass Road, Stennis Space Center, Mississippi, 39529, United States
 
ZIP Code
39529
 
Solicitation Number
80NSSC18Q0390
 
Archive Date
4/3/2018
 
Point of Contact
Joyce J. Ford, Phone: 2288136607, Tanya R. Burnett, Phone: 2288136284
 
E-Mail Address
Joyce.j.ford@nasa.gov, tanya.r.burnett@nasa.gov
(Joyce.j.ford@nasa.gov, tanya.r.burnett@nasa.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Solicitation No. 80NSSC18Q0390 Terms and Conditions We require a stepper motor system that is equipped with Harmonic Planetary Gear, programmable high step resolution (micro-stepping better than 0.01 degrees) and no backlash. We require several indispensable characteristics; incorporation high resolution Absolute Mechanical/Optical Encoder without backup battery so as to offer not only high flexibility and freedom of the layout design of the control box but also the capability of maintaining absolute positioning information even if the power shuts down during a positioning operation. Motor size 4.7x1.57 (with gears) Driver size 2.76x3.94x1.38 We also require that the positioning information is managed internally in the sensor/driver with no need to home the sensor/driver after any power or hardware failure to avoid any interruption in data acquisition. We require a built-in programmable controller that allows for up-to 256 stored operating data parameters, such as motor speed, home position, acceleration/deceleration, interrupts, step resolution, home position, motion range limits, holding current etc. to be executed by a master controller via Modbus (RTU)/RS-485 with capability to connect multiple units through one master controller.. We require that the motors operate on 24DCV in closed loop mode in order to reduce heat generation from the motor and its driver. We require that the motor's built-in controller offers high communication flexibility with the main computer allowing its easy integration with python software. We require that the motors and their accompanying software can, in real time, manage, check the performance of the motors control and monitor the motors operation parameters such as but not limited to: speed, location, temperatures, and errors.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/ecbcdb55ae1e591f34daf5da05efe6f2)
 
Record
SN04852446-W 20180315/180313231220-ecbcdb55ae1e591f34daf5da05efe6f2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.