Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 28, 2018 FBO #5969
SOLICITATION NOTICE

53 -- STUDS - Mod/Amendment (Draft) - RFQ - Mod/Amendment (Draft) - Mod/Amendment (Draft)

Notice Date
3/26/2018
 
Notice Type
Presolicitation
 
NAICS
332722 — Bolt, Nut, Screw, Rivet, and Washer Manufacturing
 
Contracting Office
Defense Logistics Agency, DLA Acquisition Locations, DLA Land and Maritime, P O Box 3990, Columbus, Ohio, 43218-3990, United States
 
ZIP Code
43218-3990
 
Solicitation Number
SPMYM118Q0060
 
Point of Contact
Romel Jackson, Phone: 7573969354
 
E-Mail Address
romel.jackson@dla.mil
(romel.jackson@dla.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL CDRL STUDS OQE Ordering Requirements for CIM Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification QQ-N281D as applicable for document # 8054B162 are as follows: a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing. b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material. c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable. d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process. e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of "start material" has been accomplished per QQ-N-286 Rev G requirements. f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported. Note 1: Enter specification Note 2: Enter the document number
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DSCC/SPMYM118Q0060/listing.html)
 
Place of Performance
Address: Norfolk Naval Shipyard, Portsmouth, Virginia, 23709, United States
Zip Code: 23709
 
Record
SN04867730-W 20180328/180326231915-919431b5196188934c5609292b03f9d2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.