Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 31, 2018 FBO #5972
SOURCES SOUGHT

J -- CLEAN HVAC DUCTING ON CGC FLYINGFISH

Notice Date
3/29/2018
 
Notice Type
Sources Sought
 
NAICS
561790 — Other Services to Buildings and Dwellings
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Base Portsmouth, 4000 Coast Guard Boulevard, Portsmouth, Virginia, 23704-2199, United States
 
ZIP Code
23704-2199
 
Solicitation Number
70Z02718S3JL001
 
Archive Date
4/21/2018
 
Point of Contact
Mathew A. Malo, Phone: 757-295-2423
 
E-Mail Address
mathew.a.malo@uscg.mil
(mathew.a.malo@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
GENERAL REQUIREMENTS: The work consists of providing all labor, materials and equipment as required to clean the HVAC system ducting onboard USCGC FLYINGFISH, located at USCG Base Portsmouth, 4000 Coast Guard Blvd. Portsmouth, VA. 23703. 2. SCOPE OF WORK: Contractor will clean all HVAC system ducting onboard USCGC FLYINGFISH. REFERENCES - Available upon request from Charles Setnicky (757) 483-8552. Coast Guard Drawings Coast Guard Drawing 87 WPB 514-001, Rev M, HVAC Duct & Piping System Coast Guard Publications Surface Forces Logistic Center Standard Specification 0000 (SFLC Std Spec 0000), 2014 General Requirements Surface Forces Logistics Center Standard Specification 5100 (SFLC Std Spec 5100), 2014, Clean Shipboard Ventilation Systems Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2014, Requirements for Preservation of Ship Structures Coast Guard Commandant Instruction (COMDINST) M10360.3, Change 1, June 2006, Coatings and Color Manual OTHER REFERENCES None Period of Performance: 20JUN18 - 20JUL18 All work must be completed by 20JUL18 Protective measures - general. The contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces in the vicinity of the work area against contamination during performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness. Additional protective measures. - In addition to providing protective covering as specified in SFLC Std Spec 5100, subsection 3.1.2 (Protective measures), provide additional protective covering for all food preparation and serving surfaces that may be affected by cleaning work, as applicable, to prevent contamination. Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the below-listed Ducting Screens. Electric Preheaters. Overhead sheating and panels. Ventilation covers. Operation test - general Operational test - initial. Prior to commencement of work, the Contractor shall witness an operationl pre-test (By Coast Guard personnel) of the ventilation systems included in this work item, to demonstrate existing operational condition. Submit a CFR. Operational test - post repairs. In the presence of the Coast Guard Inspector, the Contractor shall thoroughly test and prove the disturbed ventilation systems to be in satisfactory operating condition (see 4.1 (Equipment Operation)). Repair all leaks. Submit a CFR. Cleaning particulars. Using Coast Guard Drawing 87 WPB 514-001 as guidance, the Contractor shall accomplish the following: Clean all supply and exhaust portions of the HVAC system (all ducting leading to and from the air handler unit) in accordance with SFLC Std Spec 5100. Mark the position of all diverting, balance, and splitter dampers prior to disassembly and restore to original configuration at reassembly. Touch-up preservation, general. The Contractor shall prepare and coat all new and disturbed exterior and interior surfaces, as applicable, to match existing adjacent surfaces in accordance with SFLC Std Spec 6310, paragraph 3.1.13 (Touch-ups and minor coating repairs). 3. SITE VISIT: All bidders are strongly encouraged to visit the site to field verify any/all quantities before submitting bids. Interested parties shall make arrangements for a site visit with Charles Setnicky, 757-483-8552.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/COUSCGISCP/70Z02718S3JL001/listing.html)
 
Place of Performance
Address: USCG BASE PORTSMOUTH INDUSTRIAL, 4000 COAST GUARD BLVD, PORTSMOUTH, Virginia, 23703, United States
Zip Code: 23703
 
Record
SN04872354-W 20180331/180329231916-62223ee9b6334a4ca3e35751cd911bdd (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.