Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 03, 2018 FBO #6097
SOLICITATION NOTICE

41 -- Replace "Split" A/C unit - Telephone Exchange (PBX) Server Room - RFQ

Notice Date
8/1/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Other Defense Agencies, Defense Finance and Accounting Service, Contract Services Directorate, Columbus, 3990 East Broad Street, Bldg #21, Room 2B218, Columbus, Ohio, 43218
 
ZIP Code
43218
 
Solicitation Number
HQ042318Q0031
 
Archive Date
8/21/2018
 
Point of Contact
CHRISSCOTT61, Phone: 6147012785
 
E-Mail Address
CHRISTINE.A.SCOTT6.CIV@MAIL.MIL
(CHRISTINE.A.SCOTT6.CIV@MAIL.MIL)
 
Small Business Set-Aside
N/A
 
Description
Statement of Work - RFQ Attachment SF1449 Request for Quotes HQ042318Q0031 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-97. This is an unrestricted acquistion. The associated North American Industrial Classification System (NAICS) code for this procurement is 238220, with a small business size standard of $15 Million. Defense Finance Accounting Service is seeking quotes from Small Business that are qualified to contract services for HVAC to replace the existing "Split" A/C unit for the telephone exchange server (PBX) room currently servicing the agency. Please be advised that all interested parties that require a site visit to properly quote to ensure the product will meet the requirement shall contact the Government Point of Contact (GPOC) at least 24 hours in advance to arrange for access to the site/building. The Government Point of Contact for this requirement is David Steiner at 315-709-6062 or Dave Laplante at 315-709-6585. Please ensure adequate time is permitted in which to conduct a site visit, if required, and prepare a quote before the closing date/time listed. The contractor shall perform the following tasks: Demolition Work 1. Reclaim existing coolant and dispose of properly. 2. Secure Power following proper lockout/tag out procedures. 3. Remove interior and exterior units. New Work Provide new Split Unit, single zone, cooling only required, and provide a wireless remote control unit for operator control: New unit must be capable of cooling approximately 600 square feet of floor space (5,400 cf) and maintaining a consistent room temperature of between 68 - 72 degrees. Room currently holds 24 servers (400 watts each) that support the site phone system. There are plans to add 3 more servers in the near future, so new unit must be able to effectively cool the same area following the installation of 3 additional servers. Install new indoor and outdoor condenser. Install new refrigerant and condensate lines. Install new non-fused disconnect for outdoor unit. Re-connect electrical supply to indoor and outdoor units. If new electrical service to outdoor is found to be needed, contractor will be required to provide. Test Equipment Items Not Required: Does not include repair or diagnosis of exiting mechanical equipment. Temporary HVAC controls or start-up by others. Demolition, painting, patching of any kind is not included in this estimate Equipment start-up by others Additional Requirements: Work to be performed is expected to occur during normal working hours. Normal working hours are defined as 0630-1800 Monday through Friday. Pricing to be valid for 120 days One year warranty for new installed equipment/device. All interested small business companies shall provide a quote for the following, pricing for which can be included on Page 3 on the SF1449 provided as an attachment: CLIN0001 Quantity: 1 Unit of Issue: JOB Price: Description: Replacement of existing unit and installation of new Split Unit to cool room housing PBX telephone servers. Minimum BTU 36,000, single zone, cooling only required, wireless remote control unit for operator control. Work to be performed in accordance with the SOW provided as an attachment to the RFQ. FAR 52.212-1, Instructions to Offerors-Commercial applies to this acquistion; FAR 52.212-2 is applicable to this acquisition; Award shall be made to the vendor whose quotation provides the best value to the government, considering technical acceptability, past performance, and price. Vendors are advised to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items, with its quote; FAR Clause 52.212-4, Contract Terms and Conditions-Commercial Items applies to this acquisition; FAR Clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, applies to this acquistiion; The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html ; The following solicitation clauses/provisions also apply to this acquisition: 52.222-50, 52.223-1, 52.223-11, 52.223-12, 52.223-15, 52.223-18, 52.232-40, 52.233-3, 52.242-5, 52.252-1, 52.252-2, 52.252-5, 52.252-6, 252.201-7000, 252.203-7000, 252.203-7002, 252.203-7005, 252.204 -7003, 252.204-7007, 252.204-7011, 2252.204-7012, 52.204-7015, 252.213-7000, 252.222-7007, 252.223-7008, 252.225-7000, 252.225-7001, 252.232-7003, 252.232-7006, 252.232-7010, 252.244-7000, 252.247-7023 This is not a DPAS rated order. Quotes must be submitted on or before 4:00pm August 6, 2018. Electronic submission of quotes to the contracting officer is preferred; christine.a.scott6.civ@mail.mil. Information regarding this solicitation should be addressed to: Christine Scott at christine.a.scott6.civ@mail.mil or 614-701-2785
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/ODA/DFAS/Columbus/HQ042318Q0031/listing.html)
 
Place of Performance
Address: Defense Finance Accounting Service - Rome, 325 Brooks Road, Rome, New York, 13441, United States
Zip Code: 13441
 
Record
SN05015206-W 20180803/180801230822-b67dbb4bdfbfa16cf03251123ae2c2e5 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.