MODIFICATION
65 -- Philips CX50 CV Ultrasound - Solicitation 1
- Notice Date
- 8/8/2018
- Notice Type
- Modification/Amendment
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of the Army, U.S. Army Medical Command, MEDCOM, North Atlantic Regional Contracting Office, 8901 Rockville Pike, Bldg 54, Bethesda, Maryland, 20889, United States
- ZIP Code
- 20889
- Solicitation Number
- W91YTZ-18-Q-0080
- Archive Date
- 9/4/2018
- Point of Contact
- Mary A. Mitchell-Martin,
- E-Mail Address
-
mary.a.mitchellmartin.civ@mail.mil
(mary.a.mitchellmartin.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- J&A RELEASED SOLICITATION The Regional Health Contracting Office - Atlantic (RHCO-A), Womack Army Medical Center, Ft Bragg, North Carolina is posting a solicitation for the below Name Brand Only requirement for a CX50 CV system. Contract award will be made around the 30th of August 2018. *****SEE ATTACHED SOLICITATION OFR DETAILS***** Philips Medical Systems North America Inc., 22100 Bothell Everett Hwy, Bothell, WA, 98021-8431 is the manufacturer. 1 Each, 100662 Philips CX50 CV consisting of the following: 1 NNAP813 CX50 CV Essentials Bund 1 NUSM153 Live xPlane 1 FUS5048 Cart with Multi-port Adapter 1 FUS5101 USA Power Cord 1 NUSV671 Government Security 1 NUSN084 S5-1 / X7-2t Transducer Bundle 1 FUS5123 L12-3 Transducer 1 FUS7000 English Manual 1 FUS8201 Service Manual 1 989801299772 US2793 CX30/50 CTC3 Training No used, rebuilt, or refurbished equipment is acceptable. Only new equipment is technically acceptable. This is an all or nothing requirement; must offer all listed to be found technically acceptable for award. *** See specifications below*** Description: NNAP813 CX50 CV Essentials Bund 1 Interface: • 15.0 inch high resolution display with wide viewing angle • Quick Keys and Active Mode • Laptop style Alphanumeric QWERTY keyboard • 8 TGCs and 2 LGCs • Ergonomic carrying handle • Includes AC adapter, power cord and system battery pack • 500 GB hard drive • Internal DVD RW drive Architecture: All-digital compact broadband beamformer, Microfine 2D focusing with Dynamic Focal Tuning that includes Advanced XRES signal processing, 170 dB full time input dynamic range 504,576 digitally processed channels, Windows Embedded Standard 7 Operating System, Continuously variable steering in 2D, color and Doppler modes 2D Opt signal processing with 4X multi-line parallel processing and frequency compounding. Windows Embedded Standard 7 Operating System. Intelligent Controls: The CX50 has been designed to make portable exams easy and efficient. With a single button, iSCAN technology automatically samples data for a new level of 2D and Doppler optimization iSCAN one-touch Intelligent Optimization, iSCAN one-touch Intelligent Color Optimization, iSCAN Doppler one-touch optimization. Smart Exam: provides easy to use, customizable guides that help the clinician complete studies on every patient. An on screen menu, guides the clinician through the required views for a specific exam type, automatically enters annotation and build the patient report. Needle Visualization: When used in conjunction with the L12-3 or L12-5 50 linear transducers, Needle Visualization utilizes advanced electronic beam-steering technology to enhance viewing of the needle to assist the user in guiding the needle to the target anatomy. Transducers: The CX50 Cardiology system supports the compact family of transducers including S5-1, S12-4, S8-3, X7-2t, S7-3t, L12-5 50, L12-3, L15-7io, C8-5, D2cwc and D5cwc (Clinical Option/Clinical Package dependent). All transducers provide breakthrough frequency bandwidths and array configurations. These transducers also have ergonomically designed lightweight flexible cables and compact connectors. Modes: • 2D • M-mode • Anatomical M-mode • Color M-mode • Pulsed Wave Doppler • Color Power Angio (CPA) • Continuous Wave Doppler • Invert and Color Invert • Color compare mode • Dual mode • Duplex for simultaneous 2D and Doppler • 2D Optimization Signal Processing • Live Compare • Tissue Harmonic Imaging (THI) • Reconstructed zoom with pan (read zoom) • Write zoom • Pulse Inversion Harmonic imaging • Adaptive Doppler • Adaptive Color Doppler • Color Tissue Doppler imaging • Pulsed Wave Tissue Doppler imaging • Active Native Data - manipulation of image data DICOM Networking • Ethernet @100Mb/second Includes DICOM wired and wireless g and n. • Provides DICOM 3.0 network print and store and storage commitment • Performed Procedure Step • Modality Worklist • DICOM Structured Reporting Cineloop review On-board workstation-class data management with thumbnail previews and storage of images, loops, and reports. Retrospective and prospective clip capture to internal drive or removable media Integrated DVD/CD burning capability for storage of images or export in DICOM, JPEG and.avi for PC compatibility. Philips DICOM viewer option to imbed in media transfer for easy viewing of study on most PCs. Maintenance and Serviceability • Remote Access for Expedient Clinical and Technical Support • Flexible Service Agreements • Clinical Application and Educational Support • Scheduled Preventative Maintenance and System Optimization Security-related features • Firewall policy blocks all unnecessary ports • Operating System hardening • OS settings utilizing the DISA STIGS • Disable unnecessary services • Disable auto-run for removable media System Access Control • No restrictions - users may perform exams and access all previously completed exams or MWL data • Only patient data is locked - users may perform exams without requiring a login, but must successfully log in prior to accessing previously completed exams or Modality Worklist data. • Complete system is lockable - users and administrators must successfully log in prior to any system access Local User Management • Support for multiple unique user accounts • Support for multiple unique administrator accounts Remote User Management • Supports active directory authentication utilizing LDAP (system may not be joined to the domain) • Support for individual accounts or AD groups for users and administrators • May utilize LDAP or secure LDAP Auto logoff • Automatically logs off a user after the specified period of inactivity, user selectable Hard drive encryption • System supports various hard drive encryption policies including:128 bit, 128 bit with diffuser, 256 bit, 256 bit with diffuser Audit log export • Available protocols are UDP or TLS Media export security • Provides the ability to disable export of patient data to removable media Safeguard This is a standard computer administration tool used to prevent unauthorized programs (malware) from running on the ultrasound system. Adult Echo Clinical Option Tissue Specific Imaging software for adult cardiac ultrasound applications. Display optimization software with Tissue Specific presets for adult cardiac imaging and Doppler applications. Analysis software package includes cardiac imaging protocol measurements and configurable reports and finding codes. Active native data for post-process optimization and advanced XRES adaptive image processing for improved tissue conspicuity. iSCAN intelligent one-button optimization for adaptive gain compensation in 2D, Doppler, Tissue Doppler Imaging and LVO contrast functions. Includes Live compare mode, cardiac High-Q Automatic Doppler Analysis and respiration waveform from chest impedance. Allows operation of S5-1, CX X7-2t and D2cwc transducers. Vascular Clinical Option This clinical option includes Tissue Specific Imaging software and SonoCT for Cerebrovascular, Peripheral Vascular, Abdominal Vascular and Transcranial applications. The clinical option includes in-depth analysis and reporting packages for vascular applications including Transcranial Doppler analysis. Freehand 3D is also provided within this clinical option. This clinical option enables the C5-1, S5-1, L12-3, L15-7io and D5cwc transducers for vascular applications. This clinical option also includes Needle Visualization which utilizes advanced electronic beam steering technology to enhance viewing of the needle to assist the user in guiding the needle to the targeted anatomy - needle visualization requires the L12-3 transducer. Abdominal Clinical Option This clinical option includes abdominal Tissue Specific Imaging software, SonoCT and Freehand 3D for abdominal applications. This clinical option also includes analysis and reporting packages for abdominal applications. Allows operation for abdominal applications of the C5-1, S5-1 and L12- 3, L12-5 50, C9-3io, L10-4lap transducers. Pediatric Echo with Analysis Incorporates neonatal and pediatric echo imaging presets for S12-4 and S8-3 pediatric TTE transducers, as well as pediatric presets for S5-1 TTE and X7-2t TEE. Image optimization software includes Tissue Specific presets for 2D imaging and Doppler applications. Pediatric application includes physio (ECG) and calculations. Includes pediatric-specific analysis and supports recording of imaging loops. (NOTE: S5-1 and X7-2t require Adult Echo clinical option). Stress Echo Provides default protocols for 2, 3 and 4 stage pharmalogical, customizable protocols up to 8 stages, 8 views and options for single, quad and multicycle acquisition. Includes Gain Save feature, add stage, add view, select multiple images, reject view, skip view, edit stage, edit view, accept stage, end stage. Ability to relabel images, pause protocol/ resume protocol or interrupt protocol. Display in normal sequential order or by stage or view. Travel Case Padded wheeled travel case with front zipper pockets & telescoping handle. Includes a retractable stacking extension for transporting additional supplies and a customized transducer & gel carrying bag for up to 4 transducers. Dimensions: Accommodates CX50 imaging system, AC adapter, separate transducer carry bag for up to 4 transducers and gel Clinical Education Implementation Onsite Training - One day of basic system training is provided at your site after installation. Ultrasound system or upgrade onsite training provided by a PAS (Product Applications Specialist) for specific system applications or upgrades; not per modality. Education is provided Monday - Friday during normal business hours. Note: Philips Healthcare personnel are not responsible for actual patient contact or operation of equipment during education sessions except to demonstrate proper equipment operation. The training sessions should be attended by the appropriate healthcare professional as identified by the department director. Repeat training for staff non-attendance will not be accepted. Site must be patient-ready to meet training expectations. All onsite training day expires within 90 days from system or upgrade installation date. Exceptions are for 3D Stress onsite training (which expires 9 months from system or upgrade installation date) and Fusion & Needle Navigation onsite training (which expires 180 days from system or upgrade installation date). **NUSM153 Live xPlane 1 Live xPlane Simultaneously acquires and displays two full-resolution planes in real time. Allows independent control of tilt and rotation of second plane relative to first plane. Option requires use of Compact X7-2t TEE xMATRIX array transducer. **FUS5048 Cart with Multi-port Adapter 1 Highly mobile cart that features hardware module to support transducer switching among up to three imaging transducers at the touch of a button. Includes: 4 swivel wheels with 2 locking casters, rear handle, micro-positioning grips, quick-connect tray, storage shelf, footrest, internal isolation transformer, B&W printer brackets, integrated transducer connector holder, gel holders and cable management. Includes USB hub for additional connectivity. **FUS5101 USA Power Cord 1 **NUSV671 Government Security 1 Required by all DoD customers. This option disables VNC capabilities (which if enabled would provide remote desktop support) for increased security of data. **NUSN084 S5-1 / X7-2t Transducer Bundle 1 This Cardiology Transducer Bundle includes the S5-1 and X7-2t for use on the CX50 ultrasound system. The available imaging presets are determined by the clinical options purchased with the system. **FUS5123 L12-3 Transducer 1 Features compact connector designed for reliability and improved ergonomics. Manufactured in accordance with the European Union's Restriction of Hazardous Substances (RoHS) directive. L12-3 fine pitched, high resolution linear array with 12 to 3 Mhz extended operating frequency range for vascular, small parts, breast, musculoskeletal, contrast regional anesthesia and acute care applications **FUS7000 English Manual 1 Operation Manual **FUS8201 Service Manual 1 $222.30 $222.30 **989801299772 US2793 CX30/50 CTC3 1 $5,700.00 $5,700.00 Course Number: US2793 Class Length: 2,5 days Delivery Method: Instructor-led Modality: Ultrasound, Specialty Location: Philips Academy Training Centers Audience: Biomed Engineers System code: 795074, 795075, 795076,795096, 795097, 795114 DESCRIPTION: This course provides technical instruction for biomedical engineers (hospital engineers) on the CX30 / CX50 Ultrasound System. Students receive instruction on system components, theory of operation, disassembly, reassembly, preventative maintenance and safety checks. Hands-on labs train the students to verify proper equipment operation and diagnostic troubleshooting techniques. Philips support philosophy is explained to facilitate working successfully with our support professionals. COURSE-WARE: • All course materials are on CSIP level 1 PREREQUISITES: Basic computer knowledge Basic Ultrasound and Transducer knowledge Networking and DICOM familiarity ESD training Electrical Safety Testing COURSE OBJECTIVES: Upon completion of this course, the student will be able to: • Operate the system to determine basic functionality • Collect and deliver system status to Philips support organization • Disassemble and reassemble the major parts of the system • Perform Preventative Maintenance and Mechanical adjustments • Back-up and restore user presets • Set-up the system for DICOM communication KEY TOPICS: • Features • Theory of Operation • Disassembly and Reassembly * PHILIPS PROPRIETARY MATERIALS SUCH AS DIAGNOSTIC SOFTWARE AND SERVICE DOCUMENTATION ARE NOT INCLUDED IN THE TRAINING AND WILL NOT BE AVAILABLE FOR USE OUTSIDE OF THE TRAINING ENVIRONMENT. THE TRAINEE MUST RETURN ALL PROPRIETARY MATERIALS RECEIVED DURING THE TRAINING AT THE END OF THE TRAINING. CUSTOMER ACKNOWLEDGES AND AGREES THAT NEITHER CUSTOMER NOR TRAINEE WILL RECEIVE A LICENSE TO SUCH PROPRIETARY MATERIALS AND THAT THE TRAINEE MAY NOT BE ABLE TO FULLY UTILIZE THE TRAINING WITHOUT THE USE OF SUCH PROPRIETARY MATERIALS. (CERTAIN LICENSES MAY BE OBTAINED TROUGH PURCHASE OF RIGHTFIT AGREEMENT.) ***No telephonic request will be honored or returned. This is not a request for quotes at this time; however, if your company has information or these products, please send your capabilities statement for review. All responses will be received no later than 20 AUG 2018 at 11:00 AM EST. For more information please contact Ms. Mary A. Mitchell- Martin at mary.a.mitchellmartin.civ@mail.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA15/W91YTZ-18-Q-0080/listing.html)
- Record
- SN05027860-W 20180810/180808231631-8b468ccffd1d9af79980a0796ca38158 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)