Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 15, 2018 FBO #6109
DOCUMENT

65 -- PENTACAM CAMERA - Attachment

Notice Date
8/13/2018
 
Notice Type
Attachment
 
NAICS
339115 — Ophthalmic Goods Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
 
ZIP Code
90815
 
Solicitation Number
36C26218Q9981
 
Response Due
8/17/2018
 
Archive Date
9/1/2018
 
Point of Contact
Alvizar, Edgar
 
Small Business Set-Aside
N/A
 
Description
THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1250 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide corneal topography equipment used to measure and analyze the front part of the eye, brand name or equal product, that at a minimum meets the following salient characteristics: Measuring Equipment: Camera: Digital CCD camera Light source: Blue LEDs (475 nm, UV-free) Speed: 50 images in 2 seconds, 500 measuring points (HR: 2760) per recorded image Number of evaluated measuring points: Max. 25,000 (HR: max. 138,000) Dimensions (W x D x H): 280 x 360 x 505 535 (11.0 x 14.0 x 20.0 - 21.0 in) Weight: 11.0 kg (24.3 lbs) Measuring Range: Curvature: 3 to 38 mm, 9 to 99 D Accuracy: ± 0.1 D Reproducibility: ± 0.1 D Working distance: 80 mm Power Adapter: Power adapter HEMG 49 (05150150) Mains connection: 90 - 264 V AC Frequency: 47-63 Hz Power input, max: 85 V AC Output voltage: 24 V DC Fuses: Integrated overcurrent shut-off Power Supply: Output voltage: 24 V DC Electric consumption during operation: 42 W Other information: Lifecycle expectancy: Up to 10 years Clasifications according to IEC 60601 - 1 Type of protection against electrical shock: Protection class II Level of protection against electrical shock: Type B Level of protection against damaging water entry: IP20 Ambient Operations Requirements: Temperature: +10 °C to +40 °C Humidity: 30% to 75% Air pressure: 700hPa to 1060hPa Storage Conditions according to DIN EN 60601-1 Ambient temperature range -10 °C to +55 °C Relative humidity, including condensation 10% to 95% Air pressure range 700 hPa bis 1060 hPa Transport conditions according to DIN EN 60601-1 Ambient temperature range -40 °C to +70 °C Relative humidity, including condensation 10% to 95% Air pressure range 500 hPa to 1060 hPa Computer: Recommended computer specifications (for optional software): Win 7 pro, 2.7 GHz 8 GB RAM, 1 TB HDD, NVIDIA graphic board, (1024 x 768 true colour), USB interface Additional Services: DICOM for Pentacom On-site installation and user training as well as live online application training. Brand name Information: Manufacturer: Oculus, Inc. Item Description: System for measuring and analyzing the front part of the eye, Pentacam HR includes: Pentacam Scheimpflug Camera, XYZ moveable base, head and chin rest, power supply, USB cable, dust cover, electric height adjustable wooden design table, 21.5" all-in-one computer incl. Windows, wireless mouse, mini-keyboard and one floating license key. Includes Pachymetry Software, Densitometry Software, 3-D Chamber Analyser Software, Corneal Topography Software, Belin-Ambrosio Enhanced Ectasia software, Holladay Report, Contact Lens Fitting Software, 3D Cataract Analysis with Pentacam Nucleus Staging software, Corneal Optical Densitometry and Indices Report. One Year Warranty on Parts & Labor. Printer not included. Model: Pentacam HR The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the suppliess that fulfill the required specifications. If you are interested, and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc. (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items? (4) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract? (7) Please provide general pricing for your products/solutions for market research purposes. (8) Please submit your capabilities in regards to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? *** Submissions addressing Section (8) should show clear, compelling and convincing*** evidence that all equal to items" meet all required salient characteristics. Responses to this notice shall be submitted via email to edgar.alvizar@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, August 17, 2018 at 10:00 a.m. PST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/36C26218Q9981/listing.html)
 
Document(s)
Attachment
 
File Name: 36C26218Q9981 36C26218Q9981.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4539803&FileName=36C26218Q9981-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4539803&FileName=36C26218Q9981-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;VA Greater Los Angeles Healthcare System
Zip Code: 90073
 
Record
SN05033316-W 20180815/180813230925-57b47fef49ced28d785a8fc0021699d6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.