FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 24, 2018 FBO #6118
SOURCES SOUGHT

66 -- Sources Sought Permeation Grout Monitor

Notice Date
8/22/2018
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of the Interior, Bureau of Reclamation, BOR - All Offices, Denver Federal Center, Building 67, Room 380, Denver, Colorado, 80225, United States
 
ZIP Code
80225
 
Solicitation Number
334519TLM
 
Archive Date
9/12/2018
 
Point of Contact
Terry L. Mest, Phone: 509-633-9327
 
E-Mail Address
tmest@usbr.gov
(tmest@usbr.gov)
 
Small Business Set-Aside
N/A
 
Description
This Sources Sought notice is for informational and planning purposes only. It does not constitute a Solicitation and is not to be considered as a commitment by the Government. All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. The information from this market research is for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The intent of this notice is to determine the availability of product that will meet the following criteria: A system that integrates a flowmeter, transducers, data collection and output, and is compatible with standard geotechnical drilling equipment. The flowmeter shall be a fully-functioning system capable of measuring raw water flow in a full pipe (closed conduit), within the accuracy specified below. Each flowmeter system shall comprise the following components: • One 1-inch-diameter RST ELGL7000-HP System or equivalent. System includes a water magnetic flow meter with reported accuracy of +/- 0.25% accuracy (without flow profiling or piping straight run exceeding 1.5 diameters) • LOGGERNET Datalogger or equivalent. • Pressure transducer (compatible with downhole packer system). • Packer system (multiple components), compatible with a pressure transducer; 220 feet of air pressure line and cable. • Pipe size of one inch o Minimum Flow range 0.782 Gal/Min and o Maximum Flow range 78.00 Gal/Min • Temperature -20 Degrees C to 85 Degrees C • Suspended Solids 0 to 40% • Accuracy +/- above 1 CFS • Pressure Transducer 720 PSI Also looking for three days of training on equipment. Potential offerors having product capabilities necessary to meet the needs of the described requirement are invited to provide a capabilities statement via e-mail. The Capability statements must include the following: 1) Company name and Point of Contact information 2) DUNS number 3) Small Business Size/Certification (to include 8(a), HUBZone, SDVOSB, etc.) 4) Proposed product Manufacturer name, part number and technical literature. Responses are due no later than 5:00 PM PT, Tuesday, August 28, 2017, and shall be electronically submitted to Terry L. Mest at tmest@usbr.gov and Malena Sanderlin at msanderlin@usbr.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/17c4dcf85e7c9d7a78c8f4ea75d996a5)
 
Record
SN05050831-W 20180824/180822231258-17c4dcf85e7c9d7a78c8f4ea75d996a5 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.