Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 25, 2018 FBO #6119
SOURCES SOUGHT

61 -- RSK Powerhouse Modernization Electric Infastructure

Notice Date
8/23/2018
 
Notice Type
Sources Sought
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Tulsa, Attn: USACE, CESWT- CT, 2488 E. 81st Street, Tulsa, Oklahoma, 74137-4290, United States
 
ZIP Code
74137-4290
 
Solicitation Number
W912BV18R0059
 
Archive Date
1/31/2019
 
Point of Contact
Amanda M. McGovern, Phone: 9186697070, Brian Hutchison, Phone: 9186697426
 
E-Mail Address
Amanda.M.McGovern@usace.army.mil, brian.c.hutchison@usace.army.mil
(Amanda.M.McGovern@usace.army.mil, brian.c.hutchison@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a sources sought synopsis for the purchase and installation of a 15kV Switchgear and Bus, Generator Step-Up (GSU) and Oil Instulated Transformers. Background: Dam Purpose: Navigation, hydroelectric power, and recreation. History of Construction: Construction began in April 1964. Closure occurred in October 1970. The lock and dam became operational for navigation in December 1970. Power units 1, 2, 3, and 4 were placed on line on October 5, July 27, September 1, and November 2, 1971, respectively. Type of Structure: The dam is constructed of rolled earth-filled material. The total length of the structure, including the spillway, powerhouse intake, and navigation lock, is 7,230 feet. The maximum height is 75 feet above the streambed. There is a service road to the right embankment and an access road to the lock in the left embankment. Spillway & Outlet Works: A gated, concrete, ogee weir type spillway extends partly across the existing river channel and a portion of the right bank between the power improvements and the navigation lock. The spillway weir has a net length of 900 feet and is surmounted by eighteen 50- by 44-foot-high tainter gates. The gates are separated by seventeen 10-foot piers which support a 5-foot-wide service roadway bridge. The spillway has a capacity of 1,542,000 cfs at the maximum pool elevation(19.5 feet above the top of the power pool). Hydrologic Data: The flood of record occurred in May 1943 with an estimated peak discharge at the dam site of 810,000 cfs The United States Army Corps of Engineers is performing Market Research for the purchase of the following: Replace the four main unit 15kV switchgear line-ups, replace the 480V station service switchgear, replace the unwatering/sump pumps and motors, transformer deluge containment, rehab of transformer fire protection system, governor kidney loop system upgrade, draft tube valve and spiral valve replacement, and install/terminate new GSU transformers to be supplied and placed by another contractor, at Robert S. Kerr Lock and Dam powerhouse. The non-segregated 15kV bus from the generator to the switchgear and from the GSU transformers to the switchgear, draft tube valves, and spiral case valves will also be replaced under this project. The GSU transformer installation will require new transformer deluge containment including transformer pedestal structure modification. New equipment will replace aged and obsolete equipment, meet current applicable codes and standards while providing additional capabilities, and take advantage of new technology as appropriate. Both the design and construction aspects of this project will interface with ongoing and expected work at the powerhouse; specifically, other projects that directly relate to MEI work including the GSU transformer supply and turbine generator rehabilitation. All interested parties may respond or submit statements of qualifications via mail, fax or email. All responses are due to US Army Corps of Engineers, Tulsa District Office, Attention: Amanda McGovern, via mail: 2488 East 81st Street Tulsa, OK 74137, fax: 918-669-7495, or email: Amanda.M.McGovern@us.army.mil, not later than 2:00pm CST on September 12, 2018. Email is the preferred method when receiving responses to this sources sought notice.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA56/W912BV18R0059/listing.html)
 
Place of Performance
Address: Keota, Oklahoma, 74941, United States
Zip Code: 74941
 
Record
SN05052740-W 20180825/180823231354-8f7459cd94ab5d30cdfee204aec39215 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.