Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 25, 2018 FBO #6119
DOCUMENT

65 -- Stöckert Centrifugal Pump (SCP) System - Attachment

Notice Date
8/23/2018
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4;1010 DELAFIELD ROAD;PITTSBURGH, PA 15215
 
ZIP Code
15215
 
Solicitation Number
36C24418Q9464
 
Response Due
8/24/2018
 
Archive Date
9/23/2018
 
Point of Contact
AMANDA SAUNDERS
 
Small Business Set-Aside
N/A
 
Description
Sources Sought Notice The intent of this Sources Sought Notice is to identify potential Small Businesses especially any SDVOSB offerors capable of providing a Stöckert Centrifugal Pump (SCP) System as listed in the Statement of Need (See Below). These are for the VA Healthcare Center in Pittsburgh, pa 15215. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the Statement of Need (See Below). Responses should include the following information: Business name Address Business point of Contact Current Duns Number All information is to be submitted via e-mail at Amanda.saunders@va.gov Information provided will not be returned. All responses shall be in the English Language. Responses are due by 12:00 pm (EST) on 8/24/17. Statement of Need The VA Pittsburgh Surgical service is in need of 2 SCP Centrifugal Pumps System to replace our current Bio Console. This is a Cardiopulmonary bypass pump used for speed-controlled pumping through the cardiopulmonary bypass circuit. These pumps are used for Liver transplant but can also be used for Open Heart Procedures making this one different from other systems. We currently use these systems at the Pittsburgh VA and have all the supplies to go with it. We need to standardize. SCP Pump Control Panel Width: 180 mm Height: 270 mm Depth: 75 mm Weight: 7.7 lbs SCP Drive Unit Diameter: 3.8 in Height: 5.3 in Weight: 6.6 lbs 120w max power consumption SCP Emergency Drive Unit Diameter emergency drive unit: 3.9 in Height: 9.8 in Weight: 7.7 lbs Height hand crank: 4.5 in Diameter hand crank: 1 in Pump Date Range of speed: 0-3500 RPM; Speed accuracy: plus or minus 10 RPM Displays Range of RPM: 0-3500 RPM Resolution of the displayed actual and adjusted value: 1RPM Measurement range: Flow -10 through +10 LPM Accuracy of the measured flow: plus or minus 10% of the actual value or plus or minus 0.1 LPM, whichever is greater Alarm limits of the displayed flow: Flow too high: 0.5 through +10.0 LPM; Flow too low: 0.0 through 5.0 LPM; Retrograde flow: 0.0 through 1.0 LPM Range of pressure display: -99 through +999 mmHg Pressure display Resolution: 1 mmHg Accuracy of the measured values: Plus or minus 5 mmHg
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24418Q9464/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24418Q9464 36C24418Q9464.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4556666&FileName=36C24418Q9464-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4556666&FileName=36C24418Q9464-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN05054345-W 20180825/180823231959-eed9d49b09ab7294b304970a2902cd12 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.