Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 09, 2018 FBO #6134
SOLICITATION NOTICE

34 -- CNC Tube Bender - CNC Tube Bender

Notice Date
9/7/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of the Army, National Guard Bureau, 180 MSG/MSC, OH ANG, 2660 S. EBER ROAD, SWANTON, Ohio, 43558-9645, United States
 
ZIP Code
43558-9645
 
Solicitation Number
W9136418T8000
 
Archive Date
10/4/2018
 
Point of Contact
Matthew Michael, , Christopher Gonzales, Phone: 419-868-4142
 
E-Mail Address
usaf.oh.180-fw.list.contracting@mail.mil, usaf.oh.180-fw.list.contracting@mail.mil
(usaf.oh.180-fw.list.contracting@mail.mil, usaf.oh.180-fw.list.contracting@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
W9136418T8000 Solicitation CNC Tube Bender required should have all servo driven axes to provide a cleaner and quieter work environment. It should have all-electric design to allow the most control available while bending tubing. Operating voltage should be a standard 460V, 60Hz, 3 Phase. The machine itself should be capable of both a left-hand and also a right-hand bending capability, to include a dual-link driven bend arm and reversible bend arm rotation. Features of the Bender should include a remote start footswitch, collet control footswitch, machine mounts, air conditioner for the electrical cabinet, position controlled pressure die and pressure die assist, and a 1 meter bed length extension. The previous items should include all supports and stops required. Tooling should include all Bend Die, Clamp Die, Pressure Die, Wiper Die, Plug Die, and both 1 and 2 Ball Mandrels required for Tube manufacturing of.188" OD to 1" OD, to include all variables in size to accommodate clearance and grip. The Data center should support a windows operating system, have a minimum 17" VGA panel display, CDRW drive, USB ports, and a high speed printer. The laser tube data center should also be windows compliant and provide tube measurement, inspection, bender communications and data processing. The non-contact laser probe should accurately measure parts ranging from 0.020 to 3.0 inches in diameter without the need for multiple probes.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA33-4/W9136418T8000/listing.html)
 
Place of Performance
Address: 2660 S. Eber Rd, Swanton, Ohio, 43558-8752, United States
Zip Code: 43558-8752
 
Record
SN05078651-W 20180909/180907231142-7021458e87ee0bb717d9bff95e560987 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.