Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 13, 2018 FBO #6138
DOCUMENT

65 -- (C)436 IOLMaster 700 - Attachment

Notice Date
9/11/2018
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;6162 South Willow Drive, Suite 300;Greenwood Village CO 80111
 
ZIP Code
80111
 
Solicitation Number
36C25918Q9917
 
Response Due
9/13/2018
 
Archive Date
10/3/2018
 
Point of Contact
Brooke Barker
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT request only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The Government is NOT committed to award a contract pursuant to this announcement. This notice is published for market research purposes only. This notice is open to qualified business sources of all sizes. Information is sought regarding: The availability and capability of all qualified business sources; Whether qualified business sources are Service-Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB), small businesses, or large businesses; Vendor shall be and Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that the OEM warranty and service provided are maintained by the OEM. Provide verification when submitting quote; If the items are available via VA NAC, GSA Advantage, and/or open market; Size classification relative to the North American Industry Classification System (NAICS) code 334510 for the proposed acquisition. Requests for a solicitation will not receive a response. The purpose of this sources sought synopsis is to gain knowledge of potential qualified sources. The Government is seeking potential sources for the ZEISS IOLMaster 700 described below or equal product(s). The equal item(s) shall meet or exceed the required item(s). For equal item(s): submit detailed documentation, (i.e. descriptive literature, specifications, illustrations, pictures) stating why/how the item(s) meet or exceed each brand name item (address all stated salient characteristics). All items shall be in a new, never used condition. Required items: CLIN ITEM # DESCRIPTION QTY 0001 266002-1162-219-P ZEISS OS | IOLMaster 700 w/ SWEPT Source OCT, Option Reference Image. Includes: keyboard, mouse, printer 1 ea 0002 000000-1739-545-P ZEISS OS | ITI600 Table (YAGIII, 532S, TRION, COMBI S, FF450PLUS, VISUCAM, IOLMASTER) 1 ea Salient Characteristics: VistA approved Dicom Modality Interface Automatically transfer data into the correct patient records Ability to connect to the internet Integrated IOL calculation formulas Haigis Suite Haigis Haigis-L for eyes following myopic/hyperopic LASIK/PRK/LASEK Haigis-T for toric IOL power Hoffer Q Holladay 2 SRK/T Uses SWEPT Source OCT Provides full-length OCT image of showing anatomical details of the eye Telecentric Optics Measurement ranges: Anterior chamber depth 0.7-8mm Axial length from 14-38mm Central corneal thickness 0.2-1.2mm Corneal radii 5-11mm Lens thickness: Phakic eye 1-10mm Pseudophakic eye 0.13-2.5mm White-to-white 8-16mm Able to see Fixation from the Foveal Pit, or disease pathologies in the Foveal Pit Keratometry capture a minimum of 3 sets of 15 per eye for a total of 45 K readings within seconds White-to-white measurements allowing for use of Integrated Holladay 2 Formula Measures Pseudophakic and silicone eyes, as well as eyes with phallic IOL (in one device) Light source: wavelength 780NM Dual mode: Axial length All-in-one equipment Ethernet port for network connection and network printer Included: 1-year manufacturer warranty Delivery & Installation Training 2 operator manuals 2 service manuals Responses are to be provided to brooke.barker@va.gov no later than 4:00pm EST, Wednesday, September 12, 2018.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/36C25918Q9917/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25918Q9917 36C25918Q9917.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4585799&FileName=36C25918Q9917-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4585799&FileName=36C25918Q9917-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Fort Harrison VA Medical Center;Ophthalmology;3687 Veterans Drive;Fort Harrison, MT
Zip Code: 59636
 
Record
SN05084183-W 20180913/180911231429-d55051f4964ee95ffb6f01f51552f2a4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers