MODIFICATION
41 -- Two Liter Refrigerated Bench Top Centrifuge
- Notice Date
- 11/27/2018
- Notice Type
- Modification
- Contracting Office
- 600 Taylor Hall, West Point, NY 10996
- ZIP Code
- 22030
- Solicitation Number
- WPDEANPRDCJ008
- Response Due
- 11/29/2018
- Archive Date
- 5/28/2019
- Point of Contact
- Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
- E-Mail Address
-
Clientservices@fedbid.com;
- Small Business Set-Aside
- Total Small Business
- Description
- AMENDMENT NOTICE: This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is WPDEANPRDCJ008 and is issued as an invitation for bids (IFB), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-101. The associated North American Industrial Classification System (NAICS) code for this procurement is 333415 with a small business size standard of 750.00 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2018-11-29 11:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be West Point, NY 10928 The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: 2 Liter Refrigerated Bench Top Centrifuge (115V) - must be a refrigerated bench-top model with rotor recognition and imbalance detection; - dimensions must be 26.6 W x 24.8 D x 12.7 H in order for it to fit onto the bench specified to hold the centrifuge without safety concerns; - maximum speed greater than or equal to 18,000 rpm (30,980 x g); - minimum set temperature range = -10oC to 40oC; - minimum operating temperature range = +4oC to +40oC - conical 25 degree angle rotor (not swing-out rotor) with sealable lid is required with a capacity of at least 8 x 50 mL conical tubes, max speed greater than or equal to 12,100 rpm (16,660 x g); - conical 45 degree angle rotor (not swing-out rotor) with sealable lid is required with a capacity of at least 24 x 2.0 mL conical microcentrifuge tubes, max speed greater than or equal to 18,000 rpm (30,980 x g); - capability must exist to accept a rotor (fixed or swing-out) with sealable lid with a capacity to hold 4 x 250 mL bottles; - electrical requirements = 115/120 volts, 60 hertz, and ready to plug into wall with no adaptor. Maximum Speed: 5,100 RPM swing-out / 18,000 RPM angle rotor Maximum RCF: 5,350 xg swing-out / 30,980 xg angle rotor Temperature setting: +4 C to +37 C ClickSpin Rapid Rotor Exhange Touchscreen Controls Imbalance Detection NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (27-NOV-2018); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/notices/ad35d3a5c61ca793e4e913c397321bdd)
- Place of Performance
- Address: West Point, NY 10928
- Zip Code: 10928
- Country: US
- Zip Code: 10928
- Record
- SN05160453-F 20181129/181127230046 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |