SOURCES SOUGHT
R -- Measuring and Calibration services for Linear Accelerator Equipment - Detroit VAMC
- Notice Date
- 12/11/2018
- Notice Type
- Synopsis
- NAICS
- 541614
— Process, Physical Distribution, and Logistics Consulting Services
- Contracting Office
- Department of Veterans Affairs;Network 10 Contracting Office;Ann Arbor VA Healthcare System;2215 Fuller Road;Ann Arbor, MI 48105
- ZIP Code
- 48201
- Solicitation Number
- 36C25019Q0209
- Response Due
- 1/5/2018
- Archive Date
- 4/14/2018
- Point of Contact
- kelly.poole@va.gov
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought/Market Survey Notice is being conducted by John D. Dingell VA Medical Center, 4646 John R. Street, Detroit, Michigan, 48201 to identify other sources that are capable of providing commissioning services for the new TrueBeam linear accelerator located at the Detroit VAMC following installation. This commissioning is required prior to using this equipment. This commissioning must include: Performance of a photon and neutron Radiation Survey of the linear accelerator vault (contractor shall supply calibrated survey instruments), resulting in a formal written report following the format outlined in National Council on Radiation Protection Report No. 151. Measurement of a complete data set for a Varian Medical Systems TrueBeam linear accelerator for use with an Eclipse treatment planning system using Acuros, AAA, and e-MC algorithms, for 6, 10, and 15MV flattened and 6 and 10MV unflattened X-ray beams, and 6, 9, 12, and 16Mev electron beams (contractor shall supply measurement instrumentation). Measurement of complete data set for Enhanced Dynamic Wedges and physical hard wedges. Measurement of complete data set for electrons for standard size applicators. Measurement of complete data set for dMLC and VMAT IMRT treatment plans. Measurement of complete data set for Varian Eclipse SRS treatment plans. Measurement of complete data set for Enhanced Dynamic Wedges and physical hard wedges Perform an absolute output calibration for all radiation beams following TG-51 methodology. Results will be verified using the IROC OSLD program. A formal written commissioning report of this project will be provided after the project is completed. A formal written report of all the beam data acquired will be provided after the project is completed. If this is a service your business can provide respond to this Sources Sought by Friday, January 5, 2019, 4:00 P.M. (EST). Responses should include: (1) Business Name and Address (2) Point of Contact Name, Phone Number, and E-mail Address (3) DUNS and NAICS code (4) Business Size SMALL or LARGE (5) Type of Business SERVICE DISABLED VETERAN OWNED, VETERAN OWNED, 8A, HUBZone, WOMEN-OWNED etc. (6) Applicable GSA/FSS Contract Number (if applies). All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above noted service. E-mail responses to: Kelly Poole, at kelly.poole@va.gov. (Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.) NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (11-DEC-2018); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/DtVAMC/VAMCCO80220/36C25019Q0209/listing.html)
- Place of Performance
- Address: John D. Dingell VA Medical Center;4646 John R Street;Detroit, Michigan
- Zip Code: 48201
- Country: USA
- Zip Code: 48201
- Record
- SN05171414-F 20181213/181211230020 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)