Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 18, 2020 SAM #6624
SOLICITATION NOTICE

X -- General Services Administration (GSA) seeks to lease the following space in Newark, NJ:

Notice Date
1/16/2020 1:07:43 PM
 
Notice Type
Presolicitation
 
NAICS
531120 — Lessors of Nonresidential Buildings (except Miniwarehouses)
 
Contracting Office
PBS CENTRAL OFFICE WASHINGTON DC 20405 USA
 
ZIP Code
20405
 
Solicitation Number
4NJ0222S
 
Response Due
1/31/2020 2:00:00 PM
 
Archive Date
01/31/2020
 
Point of Contact
Frank Truesdell, Phone: 9739086121
 
E-Mail Address
frank.truesdell@cushwake.com
(frank.truesdell@cushwake.com)
 
Description
General Services Administration (GSA) seeks to lease the following space: State:�New Jersey City:�Newark Delineated Area: NORTH: Interstate 280 Essex Freeway EAST: McCarter Hwy (south) to Centre Pl to City Dock St to Raymond Blvd (west) to Alling St (south) to Edison Pl (west) to McCarter Hwy SOUTH: Kinney Street WEST: University Ave to Washington St Minimum Sq. Ft. (ABOA):�106,835 Maximum Sq. Ft. (RSF):�123,000 Space Type:�Class A, Office Space Parking Spaces (Total):�58 Parking Spaces (Reserved):�37 Parking Spaces (Secured):�21 Full Term:�15 Years Firm Term:�10 Years Option Term:�0 Years Additional Requirements: Offered�Space must be located in contiguous blocks�on contiguous floors within the offered building. Office Space cannot be located in the basement or below grade space. Approximately 40,857 ABOA Sq. Ft. of the space will be utilized for a Laboratory and Laboratory related functions. Approximately 3,747 ABOA Sq. Ft. of the space is preferred but not required to be located above the ground floor and does not need to be located on the same floor as the Laboratory space. The Government has strict ventilation specifications.� Space offered for the laboratory area must be in close proximity to a roof or other exterior area where laboratory HVAC and exhaust equipment can be mounted and conveniently ducted and otherwise connected to the offered space. The Government will�utilize�specialized equipment�in the laboratory space.� As a result, The Government has strict requirements related to building vibration. Structural slab in the laboratory shall also be constructed to minimize structure borne vibrations.� �Each offered space�shall be�submitted with a stamped engineering report verifying that the space meets the strict requirements. In areas of the lab, the slab slab ceiling height must be no less than 9�6� in most of the laboratory area, other than the NMR room where the minimum ceiling height is 11�0. The lab structural slab is required to have a 80 lbs/sf floor load in most laboratory rooms. The exceptions are the records room and library where the floor load is 150 lbs/sf. The location must be within walking distance of public transportation. Freight elevator access to all occupied floors is required.�� Building must have the ability to bring a vehicle up to and in close proximity to the freight elevator. The building shall comply with applicable security requirements of the Department of Homeland Security and will be classified as a Facility Security Level III facility.� The Government shall have access to the space 24 hours a day, 7 days a week, and 365 days a year, including freight elevator and loading dock access. Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease.� A fully serviced lease is required.� Offered space shall not be in the 100 year flood plain. ******************************************************************* The U.S. Government currently occupies office and related space in a building under a lease in Newark, NJ, that will be expiring on May 31, 2020. The Government will consider alternative space if economically advantageous. In making this determination, the Government will consider, among other things, the availability of alternative space that potentially can satisfy the Government�s requirements, as well as costs likely to be incurred through relocating, such as physical move costs, replication of tenant improvements and telecommunication infrastructure, and non-productive agency downtime. Expressions of Interest Due:�1/31/2020 Market Survey (Estimated):�TBD Occupancy (Estimated):�6/1/2020 Send Expressions of Interest to: Name/Title:�Frank Truesdell, Managing Director Address:� Cushman & Wakefield, U.S. Inc. 26 Main Street, Suite 202 Chatham, NJ 07928 Phone: Direct:� 973-908-6121 Cell: 862-204-9257 Email Address:�frank.truesdell@cushwake.com Government Contact Information: Lease Contracting Officer:�Eduardo Vidal Broker:�Cushman & Wakefield, U.S., Inc.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/5927bdfe6cf64b0ab0b8a4e56f20a848/view)
 
Place of Performance
Address: NJ, USA
Country: USA
 
Record
SN05536863-F 20200118/200116230139 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.