Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 16, 2020 SAM #6653
SOURCES SOUGHT

65 -- Teleflex Pilling Laser Laryngoscopes (VA-20-00028567)

Notice Date
2/14/2020 2:28:45 PM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24220Q0364
 
Response Due
2/25/2020 8:59:59 PM
 
Archive Date
03/06/2020
 
Point of Contact
Lateisha Robinsonlateisha.robinson@va.gov
 
E-Mail Address
lateisha.robinson@va.gov
(lateisha.robinson@va.gov)
 
Awardee
null
 
Description
Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. VHA Reginal Procurement Office (RPO) 2 is currently conducting a market survey for qualified firms capable of providing Teleplex Pilling Laser Laryngoscopes. The North American Industry Classification Systems (NAICS) is 339112. Responses to this notice must be submitted in writing (email or fax) and must be received no later than February 25, 2020 @ 10AM EST. Email: LATEISHA.ROBINSON@VA.GOV and Fax: 718-741-4722. No telephone inquiries will be accepted. Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested parties who do not submit the above information on or before the response due date and time will not be considered for this procurement. Please review the attached Statement of Work attached herein. The purpose of this notice is to gain knowledge of potential qualified sources and their size classification/socioeconomic status (service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business or large business), relative to NAICS 339112. Responses to this notice will be used by the Government to make appropriate acquisition decisions. A solicitation is not currently available. If a solicitation is issued, it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. STATEMENT OF WORK Laser Laryngoscopes and Forceps Background/Scope: The VAMC Medical Department wishes to purchase three (3) Teleflex Pilling Laser Laryngoscopes (small, medium and large). This equipment helps surgeons focus on critical anatomy during procedures in a wider range of patient anatomies and is designed for patients with a greater distance between their teeth and vocal cords. Additionally, the Northport VAMC wishes to purchase Teleflex Feder-Ossoff Micro-Laryngeal grasping and cup biopsy forceps which have aggressive serrated jaws for better holding and a suction channel with proximal fitting for smoke evacuation and improved visibility during laser procedures. Specifications: Grasping forceps: serrated jaws, 1.1 mm wide tapering to 0.6 mm, 4 mm long and a working length of 23cm, straight and angles up. Biopsy cup forceps: 1 mm jaw with a working length of 23 cm, straight and angled up. Pilling Low-Profile Dedo-Style Laser Laryngoscope: Overall length of 178 mm, minimum I.D. of 10.7 mm, nominal proximal dimensions of 19.0 mm x 19.0 mm, max O.D. 25.5 mm. Garrett-Ossoff-Pilling Adult - Extra-Long: Overall length of 188 mm, minimal distal opening of 8.0 mm, mouth proximal dimensions of 25.0 mm x 15.0 mm. Ossoff-Pilling Adult Female: Overall length of 168 mm, minimal distal opening of 7.0 mm, mouth proximal dimensions of 19.0 mm x 15.0 mm. Material Description QTY 522221 Pilling Laser Slimline Dedo Laryngoscope - Large 1 522196 Pilling Garrett Ossoff Pilling Laser Laryngoscope - Medium 1 522190 Pilling Anterior Comm Ossoff Pilling Laser Laryngoscope - Small 1 A358PRA Pilling Bule Fiber Optic Cable 1 502248 Pilling TOBEY LARYNGOSCOPE HOLDER 1 506862 Pilling 1mm PHONO CUP FCPS 1MM STRAIGHT 1 506864 Pilling 1mm PHONO CUP FCPS 1MM ANGLED UP 1 506860 Pilling 1mm PHONO GRASPING FCPS STRAIGHT 1 506858 Pilling 1mm PHONO GRASPING FCPS ANGLED UP 1 Warranty: All Surgical Instruments stamped or etched with the Pilling� brand shall be free from manufacturing defects in material or workmanship for the life of the instrument. Teleflex Medical's sole responsibility under all the warranty shall be, at Teleflex Medical's option, to either repair, replace, or refurbish any instrument proving defective, free of charge.� Pilling instruments that feature the Life-Lok box lock are warranted not to break or crack in the box lock area due to stress buildup for the life of the instrument. Other: This purchase or use of this equipment does not involve VA sensitive information/data.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/cbac988d487844a18aede7762f516c44/view)
 
Record
SN05563283-F 20200216/200214230152 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.