Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 21, 2020 SAM #6658
SOURCES SOUGHT

58 -- ALBANY PURCHASE INSTALL PAGER SYSTEM (VA-20-00009570)

Notice Date
2/19/2020 3:51:02 PM
 
Notice Type
Sources Sought
 
NAICS
334290 — Other Communications Equipment Manufacturing
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24220Q0158
 
Response Due
2/27/2020 8:59:59 PM
 
Archive Date
04/27/2020
 
Point of Contact
Collins, CharlesCharles.Collins@va.gov
 
E-Mail Address
Charles.Collins@va.gov
(Charles.Collins@va.gov)
 
Awardee
null
 
Description
Sources Sought Notice This is a Sources Sought announcement only, this is NOT a Request for Quote. The purpose of this notice is to conduct market research and obtain information from qualified vendors with special interest. No solicitation is being issued at this time. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The U.S. Department of Veterans Affairs, Network Contracting Office 2, and the Stratton VA Medical Center in Albany, NY anticipate a purchase order for the following: RADIO PAGING SYSTEM (See Statement of Work (SOW) on Page 2) The applicable North American Classification System (NAICS) Code for this requirement is 334290 (Other Communications Equipment Manufacturing). Interested vendors are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the System for Award Management (SAM) database prior to award of contract. Responses should address how you will meet the Government s needs according to the description below and provide a brief capability statement. Please include product literature that specifically addresses the technical requirements. All vendors that are interested in possibly providing these items and can meet the technical specification requirements detailed in the (SOW) that follows, are asked to submit the following information as well (all vendors regardless of business size are encouraged to respond): 1) Company Name: 2) Company Address: 3) DUNS Number: 4) Company POC Name: 5) Company POC Phone: 6) Company POC Email: 7) Company Website: 8) Business type: SB/SDVOSB/HBCU, etc.: 9) List of existing Government Contract Vehicles (GSA, FSS, DLA, DoD, SEWP, etc.) for this product/ solution if applicable: Please identify your company's small business size standard and applicable NAICS code. For more information refer to http://www.sba.gov/content/table-small-business-size-standards. Note: If claiming SDVOSB or VOSB, the firm must be registered, and CVE verified in VetBiz Registry http://www.vetbiz.gov/; also include VetBiz certification. A formal RFQ may be issued upon receipt of information pertaining to this Sources Sought Notice. If you are capable of meeting the requirements as detailed in the Statement of Work, please send your responses via email NLT 5:00pm on Tuesday, June 25, 2019 to Charles Collins, Contracting Officer, at Charles.Collins@va.gov. DO NOT SEND QUOTES AT THIS TIME Stratton VA Medical Center Albany, New York Request for Services - Statement of Work (SOW) Replace Pager System Radio Background: Stratton Veterans Administration Medical Center, located at 113 Holland Ave, Albany NY 12208 is requesting all labor, materials, equipment and travel to replace our current Zetron pager system. The current redundant system has been in service for approximately 20 years. The hard drive failed on the B side and the equipment is unable to be repaired. This request is for a direct replacement based on current configuration. Since we have been unable to repair the B side of the system the reliability is questionable, and the system has no redundancy which can lead to severe degradation during code blue calls and other pages. Scope of Work: 1. Replace existing Zetron system with a new Zetron 2200 system A & B sides. - Current Configuration: - Zetron 2200 redundant hot standby auto switch paging terminals. - Part# 905-0008 - Model# dqpc2200 Motorola. - Ser#s 00939-126. - Option# 901-9050. - FCC# EYB5Q5-19269-OT-E. - Ring EQ 0.48. - ZETRON Model 2200 ISA Bus Motherboards - 702-9502A - 702-9502B - Six phone lines per terminal. - Two station cards, and one multiport per each terminal. - Printer and voice options. - Zbase software. 2. In order to keep the pager system operational always, this work requires the removal of the B-side installation, integration and testing of new B-side. Than removal of the A-side and installation, integration and testing of new A-side radio. 3. System Requirements; - Physical: General Standard Model 2200 are equipped with a hard disk for system software, subscriber database, and voice storage, as well as an autobaud modem for remote programming, diagnostics, and factory support. Environmental: +40� to +120� F. (+5� to +50� C.), 10,000 ft. (3,000 m.) altitude, 8% to 80% relative humidity, non- condensing. Power (Model 2100): 115/230 volts AC +/- 10%, 47-63 Hz AC input 150 Watts maximum. Power (Model 2200) 115/230 volts AC +/- 10%, 47-63 Hz AC input 40-70 volts DC DC input option 300 Watts maximum. TAP Capabilities Inbound TAP: Via telephone line modems or direct RS-232 connection (up to 16 ports). Out dial TAP: Up to 32 different destinations via single external modem. TNPP Capabilities Maximum nodes supported: 64 Telco Interface Types: Central office DID selector-level (up to 7-digit feed), End-to-End loop and ground start (ring and over dial), PABX 2-wire trunk, E&M Type I 2-wire audio, Local Access telephone set for priority override. E&M Type 2 with 4-wire audio available as a separate interface. Line Coupling: 600-ohm Transformer, adjustable balance duplex hybrid. Input: DTMF (0-9, *, #, A-D), Dial Pulse (0-9) 300/1200 baud modem Dual Dial Click Decoder. Radio Transmitter Interface Configurations: Transmit only Paging, Transmit/ Receive Talk-back Paging. - Signaling Formats Analog: 2-tone sequential, 5/6-tone analog Digital: Multitone Mark IV / V / VI / VII, POCSAG (512, 1200, and 2400 aud), Golay Sequential Code (GSC), NEC D3, D4, and FLEX (1600 baud). Transmit Audio: Balanced 600-ohm transformer, selectable flat tone or -6 dB per octave de-emphasis @ 300-3000Hz, selectable flat voice or +6 dB per octave pre-emphasis. Format Encoding: Analog frequency accuracy +/-0.02%, analog tone distortion less than 0.2%, digital data stability +/- 2 ppm Remote Control: Motorola PURC (sequential signaling of up to 16 transmitter zones per channel), Quintron SCM/SCU, tone formats. Four binary TTL leads provide information for outboard controller units to select up to 16 transmitter zones per channel. Voice Capabilities (Optional) Independent Voice Channels: 14 or 28, each dynamically allocated to trunks on an as-needed basis. PageSaver Voice Message Retrieval: 72 hours voice storage, 999-second max. voice message length, 100 messages per subscriber max. (50 messages per mode), max. message retention time is 255 hours. - System Peripherals: Zetron 2200 Paging Terminal (2ea) Logging Recorder Standby System Controller (2ea) Line Transfer Panel Power Supply (2ea) Tele Interface Card Radio Interface Card (2ea) Voice Controller Punch Down Blocks. Computer for system with Z-Base Software preloaded. 3. All work must be conducted in accordance with: a. Federal Communications Commission, (FCC) CFR, Title 47: Part 47. b. Chapter XVII OSHA standard Subpart 35 Compliance with NFPA 101, & Subpart 268 Telecommunications. Provided by VA Pager radios. These were replaced 6 months ago. Inspection Provide all required inspections and performance verification testing of the new system. Period of Performance The period of performance for this service is 1 week to start after all materials have arrived and notice to proceed has been given. Place of Performance All services will be performed at the Stratton VA Medical Center, 113 Holland Avenue, Albany, NY 12208. Other Related Services (Not Included in the Scope of Work) Any services not expressly stated in this statement of work are not authorized. No other person, including the COR or any other VA personnel are authorized to request additional work be performed by the contractor. Any additional services performed that are not authorized by the contracting officer will be considered inclusive.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/9755695b8ce9464d9998e7c5b93582e4/view)
 
Place of Performance
Address: Stratton VA Medical Center;113 Holland Ave;Albany, NY 12208
Zip Code: 12208
 
Record
SN05566094-F 20200221/200219230145 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers