Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 12, 2020 SAM #6709
SOLICITATION NOTICE

J -- Repair of Power Supply

Notice Date
4/10/2020 12:19:20 PM
 
Notice Type
Presolicitation
 
NAICS
336413 — Other Aircraft Parts and Auxiliary Equipment Manufacturing
 
Contracting Office
FA8117 AFSC PZABA TINKER AFB OK 73145-3303 USA
 
ZIP Code
73145-3303
 
Solicitation Number
FA811720R0024
 
Response Due
4/27/2020 12:00:00 PM
 
Archive Date
05/12/2020
 
Point of Contact
G. Michelle McGinnis, Phone: 4057392128
 
E-Mail Address
grace.mcginnis.1@us.af.mil
(grace.mcginnis.1@us.af.mil)
 
Description
Preaward Synopsis: Sole Source � Symetrics Industries (CAGE: 22830) Solicitation will be issued on or about: 28 April and closes 27 May 2020. Solicitation number: FA8117-20-R-0024 Purchase Request number: FD20301902533 Nomenclature/Noun: Repair of Power Supply Input NSN: 6130-01-266-9739HY / Input PN: 710335-2 / Output NSN: 6130-01-266-9739HY / Output PN: 7130335-02 Application:� See PWS Description: Delivery Repair Contract: The Contractor shall provide the necessary equipment required to disassemble, analyze, troubleshoot, repair, and test assets, assemblies and/or parts that are maintained or repaired under this contract.� These services also include alignment, adjustment, calibration, testing, movement, storage and reporting status related services to the repair and return of items to the users.� Work performed under this work specification includes all actions necessary to ensure that the repair activity returns the serviceable end item with the same form, fit, function, and testability to the Government, including updating to the latest hardware/software configuration approved and funded by the government.� The extent of repair required to assure a serviceable end item efficiently serves its intended purpose shall be determined by the inspection, test, bench check, and required disassembly.� Repaired items shall pass all OEM specifications, validated by the Special Test Equipment final acceptance test.� Any component parts that do not meet specified inspection requirements, or if there is any doubt as to its serviceability or longevity shall be replaced at the Contractor�s expense.� This includes any part requiring replacement due to catastrophic failure, fatigue failure, or normal deterioration. � Purchase Request (CLIN Structure for Contract) Year NOUN NSN CLIN Qty U/I Base Major Repair 6130-01-266-9739HY 0001 12 EA Base Minor Repair 6130-01-266-9739HY 0002 1 EA Base No Fault Found 6130-01-266-9739HY 0003 1 EA Base O&A 6130-01-266-9739HY 0004 1 ���� LOT Base O&A Expedite Fee 6130-01-266-9739HY 0005 1 LOT OYI Major Repair 6130-01-266-9739HY 1001 12 EA OYI Minor Repair 6130-01-266-9739HY 1002 1 EA OYI No Fault Found 6130-01-266-9739HY 1003 1 EA OYI O&A 6130-01-266-9739HY 1004 1 LOT OYI O&A Expedite Fee 6130-01-266-9739HY 1005 1 LOT OYII Major Repair 6130-01-266-9739HY 2001 12 EA OYII Minor Repair 6130-01-266-9739HY 2002 1 EA OYII No Fault Found 6130-01-266-9739HY 2003 1 EA OYII O&A 6130-01-266-9739HY 2004 1 LOT OYII O&A Expedite Fee 6130-01-266-9739HY 2005 1 LOT OYIII Major Repair 6130-01-266-9739HY 3001 12 EA OYIII Minor Repair 6130-01-266-9739HY 3002 1 EA OYIII No Fault Found 6130-01-266-9739HY 3003 1 EA OYIII O&A 6130-01-266-9739HY 3004 1 LOT OYIII O&A Expedite Fee 6130-01-266-9739HY 3005 1 LOT OYIV Major Repair 6130-01-266-9739HY 4001 12 EA OYIV Minor Repair 6130-01-266-9739HY 4002 1 EA OYIV No Fault Found 6130-01-266-9739HY 4003 1 EA OYIV O&A 6130-01-266-9739HY 4004 1 LOT OYIV O&A Expedite Fee 6130-01-266-9739HY 4005 1 LOT Contract Type and Length:� Firm Fixed Price type contract.� Multi-year contract (Base plus Four One-Year Options) for the repair of Power Supply. � IUID Note to Contractor: If unit price exceeds $5,000, then IUID requirements will apply. � Written procedures will be used for this solicitation.� No telephone requests.� Only electronic requests received directly from the requestor are acceptable.� Only the responsible sole source solicited may submit a bid, proposal, or quotation, which shall be considered.� Note: An Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of this acquisition.� The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel.� When requested, the Ombudsman will maintain strict confidentiality as to the source of the concern.� The Ombudsman does not participate in the evaluation of proposals or in the source selection process.� Interested parties are invited to call Ombudsman at (405) 736-3273.� DO NOT CALL THIS NUMBER FOR SOLICATION REQUESTS. � All responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency. � POC: Kristen Carter (405) 734-4633, kristen.carter@us.af.mil � NAICS: 336413 �
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/82a67e4e934e4594a20b6091077417ea/view)
 
Place of Performance
Address: Tinker AFB, OK 73145, USA
Zip Code: 73145
Country: USA
 
Record
SN05617533-F 20200412/200410230143 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.