SOLICITATION NOTICE
N -- Project No. AD1 00098-3, Install Fire Detection System, Building 901, Darby Military Community, Livorno Italy
- Notice Date
- 4/22/2020 6:45:07 AM
- Notice Type
- Presolicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- 0414 AQ HQ CONTRACT AUG APO AE 09630 USA
- ZIP Code
- 09630
- Solicitation Number
- W912PF-20-Q-0033
- Response Due
- 5/8/2020 8:00:00 AM
- Archive Date
- 05/23/2020
- Point of Contact
- Patrizia Meloni, Phone: 390444617410, Cristina Pancaccini, Phone: 0039050548365
- E-Mail Address
-
patrizia.meloni2.ln@mail.mil, cristina.pancaccini2.ln@mail.mil
(patrizia.meloni2.ln@mail.mil, cristina.pancaccini2.ln@mail.mil)
- Description
- PROJECT NUMBER AND TITLE: AD1 00098-3, Install fire DETECTION SYSTEM, BUILDING 901, DARBY MILITARY COMMUNITY, LIVORNO, ITALY. SOLICITATION NUMBER: W912PF20Q0033 Description of the Project: This is a Design-Build project involving the installation of a New Fire Detection and Alarm System in building 901. Bldg. 901 is an administrative one floor building of about 200 square meters located in Camp Darby. The roof has different heights and the ceiling is partially covered with a metallic false ceiling. Some other works to be performed are the removal of the existing false ceiling and lighting fixtures and the installation of a new false ceiling and new lighting fixtures. The Design Phase consists of designing details and providing calculations and everything necessary to define all the works required to fulfill the scope of work, complying with the last version of UNI 9795. All the new components shall be EN54 compliant, NFPA72 code and UFC 3-600-01 wherever possible; designer shall perform a comparison of these codes and in case of conflict the strictest requirements shall be applied. Additionally, the works consist of modify the existing electrical panel, install a new circuit breaker to feed the New Fire Alarm Control Panel (FACP), modify the panel in order to shut down the feeding of all ventilation system (fan coil included) in case of FACP activation. All applicable Italian Laws, Italian Codes and American Codes, in particular: Italian D.M. 37/08, UNI 9795 �Sistemi fissi automatici di rivelazione e di segnalazione allarme d'incendio - Progettazione, installazione ed esercizio�, NFPA 70 �National Electric Code�, NFPA 72 �National Fire Alarm and Signaling code�, UFC 3-600-01, Fire Protection Engineering for Facilities, UFC 3-501-01, Unified Facilities Criteria, Electrical Engineering, UFC 3-520-01, Unified Facilities Criteria, Interior Electrical Systems, UFC 4-010-01, Unified Facilities Criteria, Design: DOD Minimum Antiterrorism Standards for Buildings, all applicable Italian CEI and European CEI EN norms, all applicable NFPA codes, all other applicable Unified Facilities Criteria The Construction Phase consists of performing all the features of the project as designed in phase 1 and approved by the U.S. Government, in accordance with proposed and approved design and progress plan. funding:� The project is currently not funded. Location of the work: The site of the proposed work is Darby Military Community, Livorno, Italy. Magnitude of the project:� The magnitude of this project is between $25,000 (Euro 21,467.50) and $100,000 (Euro 85,870.00) METHOD OF CONTRACTING: This will be a Request for Quotation (RFQ) resulting in a Firm-Fixed price type contract.� Performance period: 210 Calendar Days from Notice to Proceed (Design and Construction). The Performance Period will be as follows: -Design phase 120 calendar days; -Construction phase 90 calendar days; SITE VISIT: �Will be held TENTATIVELY during the period from 24 June 2020 to 07 July 2020.� The exact time and date will be confirmed to the prospective offerors with a separate notification. HOW TO PARTICIPATE: In order to participate all interested parties will be invited to indicate their interest by submitting an email not later than Close of Business (COB) by May 08, 2020, to patrizia.meloni2.ln@mail.mil. �Please indicate in your e-mail the solicitation number/project number/Title and the name of the company, the address, the phone number, the fax number, the e-mail address, and name of the person(s) who will be present at the site visit (maximum two attendees): first name, last name, date of birth, place of birth, type and number of identification document. A legible copy of the identification document(s) has to be provided.� If the person(s) has/have entry pass(es), a copy of the pass(es) has/have to be provided.� Only the person(s) who has/have provided the personal data would be allowed to attend the site visit.� The Guards will check the identification card at the gate.� The quoter(s) not present on the list will be denied the entrance to the base.� Not indicating interest as described above does not preclude the quoter from participating in this requirement. NOTE:� Interested Parties are NOT required to attend the organized site visit in order to submit a quote. We inform you that our computer does not provide proof of your mail receipt.� Therefore, to get confirmation or additional information please contact Ms.� Patrizia Meloni at patrizia.meloni2.ln@mail.mil or at 0444-617410. MISCELLANEOUS:��� The solicitation package, including the technical specifications, description of the work, drawings and all additional information, will be posted within few weeks on the following webpage: https://beta.sam.gov/ IMPORTANT NOTICE: Quoters are reminded that in order to be awarded a government contract you MUST: Have a DUNS number (Dun & Bradstreet) (http://fedgov.dnb.com/webform or phone: 02-28-455-379). Have an NCAGE code (www.dlis.dla.mil/Forms/Form_AC135.asp) numbers and To be registered in the System for Award Management (SAM) website (https://www.sam.gov/portalpublic/sam/transcript/Quick_for_International_Entity_Re. We will discuss this at the site visit.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/b21f6a4bd9d84b84a5e1d2ffd86e8a06/view)
- Record
- SN05632021-F 20200424/200422230134 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |