SOURCES SOUGHT
65 -- Carefusion Vmax Body Boxes (VA-20-00070869)
- Notice Date
- 7/18/2020 1:36:45 PM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 36C24220Q0928
- Response Due
- 7/24/2020 12:00:00 PM
- Archive Date
- 08/23/2020
- Point of Contact
- Lateisha Robinson, Contract Specialist, Phone: (718) 584-9000 ext 4334
- E-Mail Address
-
lateisha.robinson@va.gov
(lateisha.robinson@va.gov)
- Awardee
- null
- Description
- TITLE: 65-NOTICE OF INTENT TO AWARD SOLE SOURCE SOL: 36C24220Q0928 DUE: 7/24/2020 SET ASIDE: N/A NAICS: 339112 POP STATE: Not specified AGENCY: Department of Veterans Affairs James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904 POC: Lateisha Robinson | Lateisha.robinson@va.gov DESCRIPTION: NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT TO CareFusion for CareFusion VMAX Body boxes for VA Hudson Valley Healthcare System. Market research was conducted and determined that CareFusion is the only vendor capable of providing supplies & service necessary that meet the requirements. STATEMENT OF WORK TEMPLATE PFT Body Box VA Castle Point Campus Background: The current PFT units are old and are past their manufacturer s recommended replacement date. There are no servers connected to the units and patient data is no longer transmitted into VistA and CPRS. Biomed and IRM department have not been able to resolve the issue. Therefore, testing must be printed out and scanned into the patient medical record. This is causing a delay in patient tests being read and downloaded into the medical record. The PFT machines were purchased last year for Castle Point and Montrose, but we did not purchase the required body boxes to go along with it. Scope of Work: VA Hudson Valley is requesting 2 PFT body boxes. The following are the requirements that the vendor need to provide for each body box GAS and HOSE KIT TABLE VMAX 22 Table Gas and Hose Kit ADAPTER POWER CORD IEC M TO US F INSTRUMENT ASSY V62J AUTOBX Vmax Whole Body Plethysmograph. Large cabin space (72 inches H x 58 inches W with door open (29 inches door closed) x 40 inches D); Weight 265 lbs.; Internal Volume 830 liters. Testing capabilities- SVC, RAW, VTG, FVC and Compression free Flow Volume Loops (complete all tests in one or separate individually); RAW and VTG in panting or quiet breathing modes; Rotating arm allows for testing outside of cabin; Adjustable patient chair height; Cabin accommodates adult or parent holding small child; Quality assurance monitoring with 'with-in' determination of RAW and VTG for each panted effort, up to four. KIT NITROGEN LUNG VOL W/GAS V62J FRC Calibration Kit for Autobox with Gas: Allows for Nitrogen Washout Lung Volume determination in Spectra Autobox AUTO IVC- 4 LITER 115V Lung Volume Standard (Autobox QC) 110v. Precise electromechanical lung which provides the only direct method of quality assurance for Thoracic Gas Volume measurements with plethysmography. Operates automatically with Vmax. Known, accepted standard reference. PULMONARY OR EXERCISE ONSITE TRAINING 3 DAYS Pulmonary Function and/or Cardiopulmonary Exercise Onsite Training Course for 3 days with a Vyaire Medical Inc. Clinical Applications Specialist. Attendee/s will participate in an interactive session on the proper operation of pulmonary function and/or cardiopulmonary exercise device/s. Includes AARC CRCE credits for up to 3 persons IF the attendee/s are present the entire course with limited interruptions and complete a written exam and survey per AARC requirements. CEUs for additional trainees are available for purchase. -Cancellation notice must be received from customer in writing (via email is acceptable) 15 business days prior to the confirmed start date of the Training Course, or the following fees will be assessed per the Training Course cancellation policy.* *No fee applied if cancellation notice received from the Customer prior to 15 business days before the start date of the confirmed Training Course. *½ the cost of purchased training cancellation fee applied if cancellation notice received from the Customer less than 15 business days, but prior to 5 business days, before start date of confirmed Training Course. *Full cost of purchased training cancellation fee applied if cancellation notice received from Customer less than 5 business days before start date of confirmed Training Course. The full cost of purchased training will also be applied to ""no shows"" by Customer when scheduled to attend training at a training facility. - Training must be completed within 60 days of purchase date when sold as training only, or within 60 days of installation of capital device when training sold with a capital sale, not to exceed one calendar year from original date of purchase. 4. Place of Delivery: VA Castle Point Campus Building 44 Receiving Department Wappingers Falls, NY 12590.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/9cbdeb8d857c42739c8489da9667a8c5/view)
- Place of Performance
- Address: Hudson Valley VA
- Record
- SN05725574-F 20200720/200718230139 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |