SOURCES SOUGHT
65 -- Request for Information (RFI) Closes 7/30/2020 12pm EST Zoll X-Series Manual Monitor Defibrillator
- Notice Date
- 7/23/2020 8:56:20 AM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24420Q0871
- Response Due
- 7/30/2020 9:00:00 AM
- Archive Date
- 08/29/2020
- Point of Contact
- justin.erdley@va.gov, Justin Erdley, Phone: 412-360-6179
- E-Mail Address
-
Justin.Erdley@va.gov
(Justin.Erdley@va.gov)
- Awardee
- null
- Description
- Purpose and Objectives: The intent of this Sources Sought Notice is to identify in locating capable small businesses, including Service Disabled and Veteran Owned small businesses capable of providing the items as listed in the attached Statement of Need. NAICS Code 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing. These items are for the VA Butler Fire & Emergency Services Department (VAB FES) at VA Butler Healthcare located at 353 N Duffy Rd, Butler, PA 16001. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the attached document. Responses should include the following information: Business name, address, Point of Contact, business size info. All information is to be submitted via email at justin.erdley@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 12:00 PM EST, Thursday, July 30, 2020. No submissions will be accepted after this date and time. Questions can be submitted electronically to justin.erdley@va.gov. This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. GENERAL INFORMATION Scope of Work: The contractor shall provide all resources necessary to accomplish the deliverables described in this Statement of Work (SOW). Procurement is for the commissioning of one (1) new cardiac monitor in the VA Butler Fire & Emergency Services Department (VAB FES) at VA Butler Healthcare, 353 N. Duffy Rd., Butler, PA 16001. Background: VA Butler Fire & Emergency Services operates a single basic life support (BLS) ambulance licensed by the Pennsylvania Department of Health (PA DOH). VAB FES utilizes Emergency Medical Technicians (EMT) licensed by PA DOH who operate under Pennsylvania Statewide BLS Protocols. VAB FES uses local ambulance service provider Butler Ambulance Service (BAS) for all advanced life support (ALS) functions. PA DOH recently broadened the Scope of Practice for EMTs to include the application and transmission of 12-lead EKGs to receiving facilities. B. GENERAL REQUIREMENTS The contractor shall provide all equipment and other items necessary to deliver and install equipment. System Features shall include the following features described below: Fully interoperable with both Zoll X Series and R Series Manual Monitor/Defibrillators Tri-mode display monitor/defibrillator/printer Real CPR help Advisory algorithm Wi-Fi, Bluetooth, USB cellular modem capable USB data transfer capable 6.5"" (16.5cm), or larger, diagonal screen Full 12 ECG lead view with both dynamic and static 12-lead mode display CPR Dashboard quantitative depth and rate in real time, release indicator, interruption timer, perfusion performance indicator (PPI) See - Thru CPR artifact filtering End Tidal Carbon Dioxide monitoring (ETCO2) with Oridion Microstream Technology MultiTech MTC Cat M1 Cell Modem, Verizon Declaration of Conformity 3 Year Extended Warranty Delivery will be made 60-90 days after receipt of accepted purchase order Accessories shall have the following features: MFC cable MFC CPR connector A/C power adapter / battery charger A/C power cord One (1) roll printer paper 6.6 Ah Li-ion battery Carry case Operator's Manual Quick Reference Guide NIBP Welch Allyn with Smartcuff 10-foot Dual Lumen hose and SureBP Reusable Adult Medium Cuff Masimo Pulse Oximetry with Signal Extraction Technology (SET), Rainbow SET (for SpCO & SpMet), and SpO2/SpCO/SpMet Rainbow DCI Adult Reusable Sensor with connector (3 ft) Rainbow, RC-4, Reusable EMS Patient Cable (4 ft) Interpretative 12- Lead ECG with 12-Lead one step ECG cable- includes 4- Lead limb lead cable and removable precordial 6- Lead set (10) SpO2/SpCO/SpMet Rainbow Single use Sensors: Patients 10-50 kg Cuff Kit with Welch Allyn Small Adult, Large Adult and Thigh Cuffs Cuff, Child, 2-Tube, Twist lock connector Six-hour rechargeable Smart battery Single Bay Charger for the SurePower and SurePower II batteries. (Pack of 6 rolls) X Series 80mm Thermal Paper, pink with Grid OneStep Cable, X Series (2 Pair) OneStep Pediatric CPR Electrode (8 pair) CPR stat pads HVP Multi-Function CPR Electrodes CPR-D Padz and CPR Stat Padz Connector for R Series C. End Results Significantly reduced time to provide Veterans with a prehospital EKG and transmit findings to the receiving Emergency Department. Ensure compliance with PA DOH BLS protocols. Improve the cardiac diagnostic care provided to our Veteran customers. See Attached P02.Market Research RFI.pdf DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document End of Document
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/ad8405f42a9b4f1a9d633c720fdb530b/view)
- Place of Performance
- Address: VA Butler Fire & Emergency Services Department VA Butler Healthcare 353 N Duffy Rd, Butler, PA 16001 16001, USA
- Zip Code: 16001
- Country: USA
- Zip Code: 16001
- Record
- SN05732271-F 20200725/200723230154 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |