SOLICITATION NOTICE
65 -- RAD SVC; MRI MONITORING SYSTEM
- Notice Date
- 8/24/2020 12:26:05 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22L (36C262) LONG BEACH CA 90815 USA
- ZIP Code
- 90815
- Solicitation Number
- 36C26220Q1332
- Response Due
- 8/26/2020 3:00:00 PM
- Archive Date
- 09/25/2020
- Point of Contact
- latricia.williams2@va.gov, LATRICIA WILLIAMS, Phone: 562-766-2245
- E-Mail Address
-
latricia.williams2@va.gov
(latricia.williams2@va.gov)
- Awardee
- null
- Description
- Page 1 of 3 REQUEST FOR QUOTE (RFQ) 36C26220Q1332 VHA San Diego Healthcare System: MRI Monitoring System COMBINED SYNOPSIS/SOLICITATION GENERAL INFORMATION This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 - Streamlined Procedures for Evaluation and Solicitation for Commercial Items, in conjunction with FAR 13 Simplified Acquisition Procedures; and supplemented with additional information included in this notice. This solicitation document and incorporated provisions and clauses are those in effect through the Federal Acquisition Circular 2019-05, dated August 13, 2019. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office is issuing a Request For Quote (RFQ) #36C26220Q1332 as unrestricted full and open competition with the size classification relative to NAICS codes 334510 or (related) that can supply the Veterans Affairs San Diego Healthcare System with an MRI Monitor System that is brand name or equal to the requirements in this RFQ. If you are providing equal to you must provide specifications at the time of offer. DESCRIPTION OF REQUIREMENT Part # Description Quantity 3880-3 1 3880 MRI, Basic Monitor System +ETC02 ECG, SP02, NIBP & ETC02 1 EA 3885 2 MRI Monitor Remote System, Remote Tablet, Base and Recorder 1 EA 1891 3 Pole Mounts, Rotating 3880 Monitor 1 EA 3883-3 4 iPod, Invasive Pressure Transpac, 3880 1 EA 1887 5 Dual Radio Modules, 2.4GHZ, 3880/3886 1 EA 1888 6 POD Charger, Battery Bay 3885B Use 1 EA 1119M 7 Roll Stand, Non-Magnetic, 3880 Monitor 1 EA Salient Characteristics for MRI Monitoring System. This system MUST BE or have: Portable Non-Magnetic MRI Safe FDA cleared to safely operate in 30,000 Gauss (3T) An integrated peripheral capillary oxygen saturation (SpO2) monitoring device Weigh less than 10 pounds Wireless invasive blood pressure capabilities Able to turn on unit, warm up and operate within 5 seconds Non-magnetic hand-held tablet for remote monitoring A monitor that self-charges its wireless components No batteries needed for wireless components Detectable respiration flow rates of less than 80ml/min Minimum 5 lead ECG Offer a loaner system if current system needs repair. Delivery Date: Delivery shall be 30 days from date of award. If your company is submitting an equal brand, please provide explanation of how your quote is equal to the description in this RFQ and your response must address each salient characteristic. Submitting a Quote: Offeror(s) shall submit their quote on company letterhead and shall include the completed pricing forms, along with their name, address, the telephone number of the offeror, the firm s DUNS#, and total price. Offerors shall have completed FAR Clause 52.212-3 Offerors Representations and Certifications - Commercial Items in Systems for Award Management SAM at www.sam.gov as required by FAR Clause 52.212-3 Offerors Representations and Certifications - Commercial Items. All offerors shall be an authorized distributor by the manufacturer and must be able to offer full manufacturer warranties for products delivered to the Government. Award will be made to the Lowest Price Technically Acceptable (LPTA) quote. Responses to this RFQ are due by August 26, 2020, at 3:00 PM Pacific Standard Time (PST). Quotes shall be submitted electronically via email to the Contract Specialist latricia.williams2@va.gov. Offers are advised to review and monitor their emails for any correspondence regarding amendments. Correspondence or questions may be directed to the Contract Specialist with 36C26220Q1332 MRI Monitoring System in the subject line, (48) hours of the posting of this solicitation. Telephone inquiries will not be honored. Inquiries after the allotted period may not receive a response due to the time constraints of the procurement. NOTICE LISTING CLAUSES INCORPORATED BY REFERENCE The following clauses are hereby incorporated by reference (by Citation Number, Title, and Date) in accordance with the clause at FAR ""52.252-2 CLAUSES INCORPORATED BY REFERENCE"" contained in this document. See FAR 52.252-2 for an internet address (if specified) for electronic access to the full text of a clause. CLAUSES FAR Number Title Date 52.232-33 PAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT JUL 2013 52.232-40 PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS DEC 2013 52.252-2 CLAUSES INCORPORATED BY REFERENCE FEB 1998 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS NOV 2012 852.237-70 CONTRACTOR RESPONSIBILITIES APR 1984 PROVISIONS 52.211-6 BRAND NAME OR EQUAL TO. AUG 1999 52.212-1 INSTRUCTIONS TO OFFERORS- COMMERCIAL ITEMS APR 2014 52.212-2 EVALUATION-- COMMERCIAL ITEMS OCT 2014 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS- -COMMERCIAL ITEMS NOV 2014 The order cannot be split, quotes must include all items.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/d25f7d7c7f4a43d8891feeb6cf7af500/view)
- Place of Performance
- Address: VA SAN DIEGO HEALTHCARE SYSTEM 3350 LA JOLLA VILLAGE DRIVE WAREHOUSE BLDG. 1 SAN DIEGO, CA 92161, USA
- Country: USA
- Country: USA
- Record
- SN05771397-F 20200826/200824230153 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |